EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitOpen Access · CC BY 4.0

Toward safe clinical deployment of remote robotic surgery in Japan: five-year validation of the hinotori™ system using 5G wireless communication

Takuto Hara, Yoshifumi Morihiro, Yuki Horise, Shuhei Komatsu, Masanao Ohashi, Hiroaki Kitatsuji, Akihisa Yao, Yoshihiro Muragaki, Hideaki Miyake

International Journal of Clinical Oncology · 2025

DOI: 10.1007/s10147-025-02874-3 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift International Journal of Clinical Oncology, 2025. Verfasst von Takuto Hara und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, Kobe University Graduate School of Medicine, 7-5-1, Kusunoki-cho, Kobe, 650-0017, Japan. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Wireless Technology. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 71 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Cabinet Office Research Grant, Recipient Project of the Government Grant for the Establishment of Regional Universities and Industries for FY2020, Urban Innovation Kobe grant.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Remote robotic-assisted surgery (RRAS), a form of telesurgery, offers a potential solution to Japan’s surgeon shortage and regional disparities in care. Despite advances in robotic systems and modern communication technologies, including both 5G wireless and wired networks, clinical adoption remains limited due to regulatory, infrastructural, and institutional barriers. This review consolidates five years (2020–2025) of technical and operational validation of the hinotori™ Surgical Robot System—a domestically developed platform—in alignment with the 2022 Japanese Remote Surgery Guidelines. Based on over 30 remote-session evaluations by Kobe University, Medicaroid, and NTT DOCOMO, we summarize system performance across key domains: communication latency, QoS-based prioritization, VPN redundancy, fail-safe mechanisms, electromagnetic compatibility, human–system interaction, and legal compliance. Under optimized Sub6 5G SA conditions, the system consistently achieved a round-trip latency of approximately 100 ms and stable stereoscopic video transmission, even during simulated 1 Gbps congestion. Safety was ensured through automatic standby, dual-cockpit fallback, and real-time monitoring. Although hinotori™ meets technical and safety criteria, full-scale implementation remains constrained by legal requirements—particularly the mandate for an on-site physician under Article 20 of the Medical Practitioners Act. Supervised telesurgery, where remote surgeons assist on-site teams, is legally permissible and may serve as a transitional model. This review integrates technical findings with policy considerations, proposing a path toward safe, equitable, and sustainable RRAS deployment in Japan. To our knowledge, this is the first comprehensive review aligning domestic telesurgical validation with national policy benchmarks, offering a foundation for future regulation, accreditation, and digital surgical integration.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Robotic Surgical ProceduresWireless TechnologyHumansJapanTelemedicine

Stichwörter der Autor:innen

5G communicationRobotic surgeryTelesurgery

Autor:innen und Institutionen

  • Department of Urology, Kobe University Graduate School of Medicine, 7-5-1, Kusunoki-cho, Kobe, 650-0017, Japan.
  • Solution Technology Group, Mobile Innovation Tech Department, NTT DOCOMO, INC., Chiyoda-ku, Tokyo, Japan.
  • System Development Department, Medicaroid Corporation, Chuo-ku, Kobe, Japan.
  • Medicaroid Corporation, Chuo-ku, Kobe, Japan.
  • Faculty of Medical Device Engineering, Kobe University Graduate School of Medicine, Kobe, Japan.
  • Department of Urology, Kobe University Graduate School of Medicine, 7-5-1, Kusunoki-cho, Kobe, 650-0017, Japan. hmiyake@med.kobe-u.ac.jp.

Förderung

  • Cabinet Office Research Grant
  • Recipient Project of the Government Grant for the Establishment of Regional Universities and Industries for FY2020
  • Urban Innovation Kobe grant
  • NTT DOCOMO, INC
  • Medicaroid Corporation
  • Kobe University

Zitieren

APA

Hara, T., Morihiro, Y., Horise, Y., Komatsu, S., Ohashi, M., Kitatsuji, H., Yao, A., Muragaki, Y., & Miyake, H. (2025). Toward safe clinical deployment of remote robotic surgery in Japan: five-year validation of the hinotori™ system using 5G wireless communication. International Journal of Clinical Oncology. https://doi.org/10.1007/s10147-025-02874-3

Vancouver

Hara T, Morihiro Y, Horise Y, Komatsu S, Ohashi M, Kitatsuji H, et al. Toward safe clinical deployment of remote robotic surgery in Japan: five-year validation of the hinotori™ system using 5G wireless communication. International Journal of Clinical Oncology. 2025. doi:10.1007/s10147-025-02874-3

BibTeX
@article{Hara2025,
  author = {Hara, Takuto and Morihiro, Yoshifumi and Horise, Yuki and Komatsu, Shuhei and Ohashi, Masanao and Kitatsuji, Hiroaki and Yao, Akihisa and Muragaki, Yoshihiro and Miyake, Hideaki},
  title = {Toward safe clinical deployment of remote robotic surgery in Japan: five-year validation of the hinotori™ system using 5G wireless communication},
  journal = {International Journal of Clinical Oncology},
  year = {2025},
  doi = {10.1007/s10147-025-02874-3}
}
Kostenlos starten →