EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

A novel bone screw implantation strategy in C1-2 instability: a framework for evolving high cervical spine surgery

Chih-Ju Chang, Kai-Chieh Chang, Zhao-Quan Liu, Yu-Ching Hsiao, Jing-Jing Fang

Neurosurgical Review · 2026

DOI: 10.1007/s10143-025-04098-5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Neurosurgical Review, 2026. Verfasst von Chih-Ju Chang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Division of Neurosurgery, Department of Surgery, Cathay General Hospital, Taipei, Taiwan. Hauptthemen laut MEDLINE: Joint Instability, Atlanto-Axial Joint, Cervical Vertebrae, Pedicle Screws. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Cheng Kung University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Fixation surgery for atlantoaxial instability (AAI) or atlantoaxial subluxation is recognized as a complex and high-risk procedure, prompting the development of various fixation techniques. In this preliminary study, we evaluated the safety and accuracy of C1-2 pedicle screw insertion using our developed planning software and 3D-printed guiding templates. We also analyzed feasibility with free-hand techniques to identify an optimal strategy for atlantoaxial fixation. We used a self-developed 3D planning method, along with guiding template techniques, for pedicle screws in high cervical vertebra fixation. A small cohort of thirteen patients in Group 1 received free-hand screw placement, while seventeen in Group 2 performed using the planning and guiding system. We analyzed demographics, complications, and screw placement precision. We compared the demographics, operative time, and blood loss between the two groups. Complications occurred in patients from Group 1, but none in those from Group 2. Most Group 2 patients underwent the C1 and C2 pedicle screws approach, which showed significantly higher screw placement safety. Both pedicle screws applied in C1 and C2 are preferable to occipitocervical fusion when feasible. The planning strategy and its associated guiding system improve the implanted screws precision and safety of pedicle screw placement, particularly in cases with high-riding vertebral arteries. When the C2 pedicle diameter exceeds 3 mm, we safely perform the C2 pedicle screws. This method supports more precise preoperative planning for atlantoaxial instability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Joint InstabilityAtlanto-Axial JointCervical VertebraePedicle ScrewsSpinal FusionHumansFemaleMaleMiddle AgedAdult

Stichwörter der Autor:innen

3D-printed guiding templateAtlantoaxial instabilityC1-C2 pedicle screwHigh cervical spine surgeryHigh-riding vertebra arteryPlanning strategy

Autor:innen und Institutionen

  • Division of Neurosurgery, Department of Surgery, Cathay General Hospital, Taipei, Taiwan.
  • Department of Medicine, School of Medicine, Fu Jen Catholic University, New Taipei, Taiwan.
  • Department of Mechanical Engineering, National Cheng Kung University, Tainan, 701, Taiwan.
  • Department of Mechanical Engineering, National Cheng Kung University, Tainan, 701, Taiwan. fangjj@mail.ncku.edu.tw.

Förderung

  • National Cheng Kung University

Zitieren

APA

Chang, C. J., Chang, K. C., Liu, Z. Q., Hsiao, Y. C., & Fang, J. J. (2026). A novel bone screw implantation strategy in C1-2 instability: a framework for evolving high cervical spine surgery. Neurosurgical Review. https://doi.org/10.1007/s10143-025-04098-5

Vancouver

Chang CJ, Chang KC, Liu ZQ, Hsiao YC, Fang JJ. A novel bone screw implantation strategy in C1-2 instability: a framework for evolving high cervical spine surgery. Neurosurgical Review. 2026. doi:10.1007/s10143-025-04098-5

BibTeX
@article{Chang2026,
  author = {Chang, Chih-Ju and Chang, Kai-Chieh and Liu, Zhao-Quan and Hsiao, Yu-Ching and Fang, Jing-Jing},
  title = {A novel bone screw implantation strategy in C1-2 instability: a framework for evolving high cervical spine surgery},
  journal = {Neurosurgical Review},
  year = {2026},
  doi = {10.1007/s10143-025-04098-5}
}
Kostenlos starten →