EUVIMEDEUVIMED entdecken
Vergleichsstudie

Diagnostic yield and safety of frame-based versus robot-assisted stereotactic brain biopsy: a matched cohort analysis

Charles-Henry Mallereau, Julien Todeschi, Lucia Nichelli, Salvatore Chibbaro, Karima Mokhtari, Helene Cebula, Alexandre Carpentier, Bertrand Mathon

Neurosurgical Review · 24.01.2026 · 49 (1)

DOI: 10.1007/s10143-025-04092-x ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Neurosurgical Review, online erschienen am 24.01.2026. Verfasst von Charles-Henry Mallereau und 7 weiteren Autor:innen. Beteiligte Einrichtung: Sorbonne University, Department of Neurosurgery, La Pitié-Salpêtrière Hospital, AP-HP, Paris, France. mallereau.charles@gmail.com. Hauptthemen laut MEDLINE: Stereotaxic Techniques, Robotic Surgical Procedures, Brain, Brain Neoplasms. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 43 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Frame-based stereotactic biopsy has long been the gold standard for diagnostic brain biopsy, whereas robot-assisted stereotactic techniques have emerged as promising alternatives. However, rigorous methodological comparisons between these approaches remain scarce. To compare the diagnostic yield and complication rates of frame-and robot-assisted stereotactic brain biopsy using a rigorously matched cohort methodology. This retrospective, bicentric, comparative analysis included adult patients who underwent stereotactic brain biopsy between January 2011 and December 2019. Each patient who underwent robot-assisted biopsy (n = 230) was matched in a 2:1 ratio with patients who underwent frame-based biopsy (n = 460). Matching was performed based on clinically relevant criteria including lesion location, size, contrast enhancement, histopathology, and patient age. The primary outcomes were diagnostic yield and complication rates. The diagnostic yield was identical for both techniques 97.4%, with a non-diagnostic biopsy rate of 2.6% in each group (p = 1.0). The symptomatic temporary complication rates were higher in the robot-assisted group (6.5%) than in the frame-based group (2.8%) (OR = 2.40; 95% CI: 1.04-5.58; p = 0.02). No differences were found in symptomatic hemorrhage, infection, seizures, permanent neurological deficits, or mortality between groups. Frame-based and robot-assisted stereotactic biopsy techniques demonstrated equivalent diagnostic efficacies. Although robot-assisted biopsies were associated with a higher incidence of transient symptomatic complications, both techniques exhibited favorable safety profiles with respect to severe complications. The choice of technique should consider the surgeon's experience, institutional resources, and integration within existing workflows.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Stereotaxic TechniquesRobotic Surgical ProceduresBrainBrain NeoplasmsHumansFemaleMiddle AgedMaleRetrospective StudiesBiopsyAgedAdultCohort StudiesBrain Diseases

Stichwörter der Autor:innen

Brain biopsyBrain tumorDiagnostic yieldRoboticsSafetyStereotactic techniques

Autor:innen und Institutionen

  • Sorbonne University, Department of Neurosurgery, La Pitié-Salpêtrière Hospital, AP-HP, Paris, France. mallereau.charles@gmail.com.
  • Department of Neurosurgery, Hautepierre Hospital, Strasbourg University Hospital, Strasbourg, France. mallereau.charles@gmail.com.
  • Department of Neurosurgery, Hautepierre Hospital, Strasbourg University Hospital, Strasbourg, France.
  • Department of Radiology and Medical Imaging, La Pitié-Salpêtrière Hospital, Paris, France.
  • Neurosurgery Unit, Azienda Ospedaliero-Universitaria Senese, "Policlinico Santa Maria alle Scotte", University Hospital, and Dipartimento di Scienze Mediche, Chirurgiche e Neuroscienze, University of Siena, Siena, Italy.
  • Department of Pathology, La Pitié-Salpêtrière Hospital, Paris, France.

Zitieren

APA

Mallereau, C. H., Todeschi, J., Nichelli, L., Chibbaro, S., Mokhtari, K., Cebula, H., Carpentier, A., & Mathon, B. (2026). Diagnostic yield and safety of frame-based versus robot-assisted stereotactic brain biopsy: a matched cohort analysis. Neurosurgical Review, 49(1). https://doi.org/10.1007/s10143-025-04092-x

Vancouver

Mallereau CH, Todeschi J, Nichelli L, Chibbaro S, Mokhtari K, Cebula H, et al. Diagnostic yield and safety of frame-based versus robot-assisted stereotactic brain biopsy: a matched cohort analysis. Neurosurgical Review. 2026;49(1). doi:10.1007/s10143-025-04092-x

BibTeX
@article{Mallereau2026,
  author = {Mallereau, Charles-Henry and Todeschi, Julien and Nichelli, Lucia and Chibbaro, Salvatore and Mokhtari, Karima and Cebula, Helene and Carpentier, Alexandre and Mathon, Bertrand},
  title = {Diagnostic yield and safety of frame-based versus robot-assisted stereotactic brain biopsy: a matched cohort analysis},
  journal = {Neurosurgical Review},
  year = {2026},
  volume = {49},
  number = {1},
  doi = {10.1007/s10143-025-04092-x}
}
Kostenlos starten →