Ultrasound-measured optic nerve sheath diameter as a non-invasive tool for screening elevated-pressure from normal-pressure hydrocephalus: a cross-sectional study
Neurosurgical Review · 2025
DOI: 10.1007/s10143-025-03906-2 ↗Kurz gefasst
Querschnittstudie in der Zeitschrift Neurosurgical Review, 2025. Verfasst von Jianhuan Wen und 9 weiteren Autor:innen. Beteiligte Einrichtung: Neurosurgery Center, Zhujiang Hospital, Southern Medical University, Guangzhou, China. Hauptthemen laut MEDLINE: Optic Nerve, Hydrocephalus, Normal Pressure, Intracranial Hypertension. Die Arbeit nennt 39 Literaturangaben.
Abstract (Originalsprache)
This study evaluates the diagnostic accuracy of ultrasound-measured optic nerve sheath diameter (US-ONSD) in distinguishing elevated-pressure hydrocephalus from normal-pressure hydrocephalus (NP-HCP), with the aim of establishing clinically relevant ONSD thresholds for screening and confirming elevated intracranial pressure (ICP) in clinical practice. This cross-sectional study, conducted at the Neurosurgery Center of Zhujiang Hospital, included patients diagnosed with hydrocephalus. Standardized US-ONSD measurements were performed on all participants, followed by lumbar puncture (LP) to measure ICP. The diagnostic accuracy of US-ONSD measurements was evaluated using receiver operating characteristic (ROC) curve analysis, focusing on sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). A 2 × 2 contingency table was used to determine the optimal ONSD thresholds for screening and confirming elevated ICP. A total of 42 hydrocephalus patients were included in this study: 22 patients with elevated-pressure hydrocephalus and 20 with normal-pressure hydrocephalus. The mean ONSD was significantly higher in the elevated-pressure group compared to the normal-pressure group (5.60 mm vs. 4.70 mm, p < 0.001). The overall cohort had a mean age of 53.6 years (SD 15.7), with 20 males (47.6%). The average weight, height, and body mass index (BMI) were 59.0 kg (SD 9.8), 163.2 cm (SD 7.3), and 22.1 kg/m² (SD 3.2), respectively. Receiver operating characteristic (ROC) analysis demonstrated excellent diagnostic performance (AUC = 0.957, 95% CI: 0.888-1.000). The optimal ONSD thresholds for excluding elevated ICP were 4.82 mm (NPV = 1), and for confirming elevated ICP were 5.75 mm (PPV = 1), thereby maximizing sensitivity and specificity. US-ONSD is a reliable, non-invasive method for detecting elevated ICP in patients with hydrocephalus. We propose two ONSD threshold values for clinical application: 4.82 mm for excluding elevated ICP and 5.75 mm for confirming it. These thresholds provide a practical and effective approach for screening and confirming elevated ICP, particularly in scenarios where invasive procedures, such as lumbar puncture, are not feasible or are contraindicated. Further multi-center studies are needed to validate these thresholds and optimize their clinical utility.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Neurosurgery Center, Zhujiang Hospital, Southern Medical University, Guangzhou, China.
- Zhujiang Hospital, Southern Medical University, Guangzhou, China.
- Zhujiang Hospital, Southern Medical University, Guangzhou, China. 981606658@qq.com.
- Neurosurgery Center, Zhujiang Hospital, Southern Medical University, Guangzhou, China. eguoyanwu@163.com.
- Zhujiang Hospital, Southern Medical University, Guangzhou, China. eguoyanwu@163.com.
- Neurosurgery Center, Zhujiang Hospital, Southern Medical University, Guangzhou, China. jessie0860@sina.cn.
Zitieren
APA
Wen, J., Zhang, L., Yang, X., Mo, Y., Zhang, S., Zhang, Y., Zeng, Y., Gao, L., Guo, Y., & Xie, T. (2025). Ultrasound-measured optic nerve sheath diameter as a non-invasive tool for screening elevated-pressure from normal-pressure hydrocephalus: a cross-sectional study. Neurosurgical Review. https://doi.org/10.1007/s10143-025-03906-2
Vancouver
Wen J, Zhang L, Yang X, Mo Y, Zhang S, Zhang Y, et al. Ultrasound-measured optic nerve sheath diameter as a non-invasive tool for screening elevated-pressure from normal-pressure hydrocephalus: a cross-sectional study. Neurosurgical Review. 2025. doi:10.1007/s10143-025-03906-2
BibTeX
@article{Wen2025,
author = {Wen, Jianhuan and Zhang, Lu and Yang, Xing and Mo, Yixiang and Zhang, Shizhong and Zhang, Yu and Zeng, Yuqing and Gao, Lijie and Guo, Yanwu and Xie, Tao},
title = {Ultrasound-measured optic nerve sheath diameter as a non-invasive tool for screening elevated-pressure from normal-pressure hydrocephalus: a cross-sectional study},
journal = {Neurosurgical Review},
year = {2025},
doi = {10.1007/s10143-025-03906-2}
}
EUVIMED