EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Impact of biologically effective dose on tremor decrease after stereotactic radiosurgical thalamotomy for essential tremor: a retrospective longitudinal analysis

Constantin Tuleasca, Guillaume Carey, Romain Barriol, Gustavo Touzet, Francois Dubus, Defebvre Luc, Nicolas Carriere, Nicolas Reyns

Neurosurgical Review · 2024

DOI: 10.1007/s10143-024-02296-1 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Neurosurgical Review, 2024. Verfasst von Constantin Tuleasca und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Neurosciences, Neurosurgery Service and Gamma Knife Center, Lausanne University Hospital (CHUV), Rue du Bugnon 44-46, BH-08, C…. Hauptthemen laut MEDLINE: Essential Tremor, Radiosurgery. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Lausanne.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Stereotactic radiosurgery (SRS) is one of the surgical alternatives for drug-resistant essential tremor (ET). Here, we aimed at evaluating whether biologically effective dose (BED Gy2.47 ) is relevant for tremor improvement after stereotactic radiosurgical thalamotomy in a population of patients treated with one (unplugged) isocenter and a uniform dose of 130 Gy. This is a retrospective longitudinal single center study. Seventy-eight consecutive patients were clinically analyzed. Mean age was 69.1 years (median 71, range 36–88). Mean follow-up period was 14 months (median 12, 3–36). Tremor improvement was assessed at 12 months after SRS using the ET rating assessment scale (TETRAS, continuous outcome) and binary (binary outcome). BED was defined for an alpha/beta of 2.47, based upon previous studies considering such a value for the normal brain. Mean BED was 4573.1 Gy 2.47 (median 4612, 4022.1–4944.7). Mean beam-on time was 64.7 min (median 61.4; 46.8–98.5). There was a statically significant correlation between delta (follow-up minus baseline) in TETRAS (total) with BED ( p = 0.04; beta coefficient − 0.029) and beam-on time ( p = 0.03; beta coefficient 0.57) but also between TETRAS (ADL) with BED ( p = 0.02; beta coefficient 0.038) and beam-on time ( p = 0.01; beta coefficient 0.71). Fractional polynomial multivariate regression suggested that a BED > 4600 Gy 2.47 and a beam-on time > 70 min did not further increase clinical efficacy (binary outcome). Adverse radiation events (ARE) were defined as larger MR signature on 1-year follow-up MRI and were present in 7 out of 78 (8.9%) cases, receiving a mean BED of 4650 Gy 2.47 (median 4650, range 4466–4894). They were clinically relevant with transient hemiparesis in 5 (6.4%) patients, all with BED values higher than 4500 Gy 2.47 . Tremor improvement was correlated with BED Gy 2.47 after SRS for drug-resistant ET. An optimal BED value for tremor improvement was 4300–4500 Gy 2.47 . ARE appeared for a BED of more than 4500 Gy 2.47 . Such finding should be validated in larger cohorts.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Essential TremorRadiosurgeryHumansAgedTremorRetrospective StudiesThalamusTreatment Outcome

Stichwörter der Autor:innen

Biologically effective doseEssential tremorRadiosurgeryTETRAS

Autor:innen und Institutionen

  • Department of Clinical Neurosciences, Neurosurgery Service and Gamma Knife Center, Lausanne University Hospital (CHUV), Rue du Bugnon 44-46, BH-08, CH-1011, Lausanne, Switzerland. constantin.tuleasca@gmail.com.
  • Faculty of Biology and Medicine (FBM), University of Lausanne (UNIL), Lausanne, Switzerland. constantin.tuleasca@gmail.com.
  • Ecole Polytechnique Fédérale de Lausanne (EPFL, LTS-5), Lausanne, Switzerland. constantin.tuleasca@gmail.com.
  • Univ. Lille, Inserm, CHU Lille, U1172 - LilNCog - Lille Neuroscience & Cognition, Lille, France.
  • Neurosurgery Department, CHU-Lille, Roger Salengro Hospital, 1, Rue Emile Laine, 59000, Lille, France.
  • Medical Physics Department, University Hospital, Lille, France.

Förderung

  • University of Lausanne

Zitieren

APA

Tuleasca, C., Carey, G., Barriol, R., Touzet, G., Dubus, F., Luc, D., Carriere, N., & Reyns, N. (2024). Impact of biologically effective dose on tremor decrease after stereotactic radiosurgical thalamotomy for essential tremor: a retrospective longitudinal analysis. Neurosurgical Review. https://doi.org/10.1007/s10143-024-02296-1

Vancouver

Tuleasca C, Carey G, Barriol R, Touzet G, Dubus F, Luc D, et al. Impact of biologically effective dose on tremor decrease after stereotactic radiosurgical thalamotomy for essential tremor: a retrospective longitudinal analysis. Neurosurgical Review. 2024. doi:10.1007/s10143-024-02296-1

BibTeX
@article{Tuleasca2024,
  author = {Tuleasca, Constantin and Carey, Guillaume and Barriol, Romain and Touzet, Gustavo and Dubus, Francois and Luc, Defebvre and Carriere, Nicolas and Reyns, Nicolas},
  title = {Impact of biologically effective dose on tremor decrease after stereotactic radiosurgical thalamotomy for essential tremor: a retrospective longitudinal analysis},
  journal = {Neurosurgical Review},
  year = {2024},
  doi = {10.1007/s10143-024-02296-1}
}
Kostenlos starten →