Improved computer-aided detection performance for pulmonary embolism on CTPA with higher noise reduction reconstruction
Emergency Radiology · 12.06.2026 · 33 (5) · 991-998
DOI: 10.1007/s10140-026-02500-3 ↗Kurz gefasst
Fachartikel in der Zeitschrift Emergency Radiology, online erschienen am 12.06.2026. Verfasst von Eline Langius-Wiffen und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Isala Hospital, Dr. van Heesweg 2, Zwolle, 8025 AB, the Netherlands. elinelangius@gmail.com. Hauptthemen laut MEDLINE: Pulmonary Embolism, Computed Tomography Angiography, Radiographic Image Interpretation, Computer-Assisted. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 26 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: To investigate whether a higher image noise reduction improves the diagnostic accuracy of Computer-Aided Detection (CAD) software to detect pulmonary embolism (PE) on CT pulmonary angiography (CTPA). METHODS: We retrospectively included 238 consecutive CTPAs of patients with suspected PE obtained between 01/09/2014 and 06/03/2014. Hybrid iterative reconstruction (HIR) was performed using either iDose4 level 3 or level 4 with 23% vs. 29% noise reduction, respectively. CAD software marked all potential PE. Two radiologists evaluated CAD markers and classified them as either true positive (TP) or false positive (FP). The reference standard was determined by a consensus reading of two experienced radiologists. RESULTS: In total, 110 scans made use of iDose4 level 3 HIR and 128 scans made use of iDose4 level 4 HIR. PE was present in 34 patients in the iDose4 level 3 group (30.9%) and in 39 patients in the iDose4 level 4 group (30.5%). Sensitivity of CAD software was not significantly different between noise reduction groups level 3 and level 4 (100% and 92.3% respectively, p = 0.24). Specificity was significantly higher in the level 4 group compared to the level 3 group (48.3% vs. 11.8%, p < 0.001). CNR was significantly higher in CT images with level 4 noise reduction (12.0 vs. 9.8, p < 0.001). CONCLUSION: CAD software produced significantly fewer FP PE markers in images with higher CNR, reconstructed using a higher noise-reduction setting. The noise reduction level 4 images had significantly higher CNR values, indicating that image quality has a substantial impact on the performance of CAD software.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, Isala Hospital, Dr. van Heesweg 2, Zwolle, 8025 AB, the Netherlands. elinelangius@gmail.com.
- Department of Radiology, Isala Hospital, Dr. van Heesweg 2, Zwolle, 8025 AB, the Netherlands.
- Department of Pulmonology, Isala Hospital, Dr. van Heesweg 2, Zwolle, 8025 AB, the Netherlands.
- Department of Radiology, University Medical Centre Utrecht, Heidelberglaan 100, Utrecht, 3584 CX, the Netherlands.
Zitieren
APA
Langius-Wiffen, E., Hendriks, N., Nijholt, I. M., de Boer, E., Walen, S., van den Berg, J. W., de Jong, P. A., & Boomsma, M. F. (2026). Improved computer-aided detection performance for pulmonary embolism on CTPA with higher noise reduction reconstruction. Emergency Radiology, 33(5), 991-998. https://doi.org/10.1007/s10140-026-02500-3
Vancouver
Langius-Wiffen E, Hendriks N, Nijholt IM, de Boer E, Walen S, van den Berg JW, et al. Improved computer-aided detection performance for pulmonary embolism on CTPA with higher noise reduction reconstruction. Emergency Radiology. 2026;33(5):991-998. doi:10.1007/s10140-026-02500-3
BibTeX
@article{LangiusWiffen2026,
author = {Langius-Wiffen, Eline and Hendriks, Nikki and Nijholt, Ingrid M and de Boer, Erwin and Walen, Stefan and van den Berg, Jan Wk and de Jong, Pim A and Boomsma, Martijn F},
title = {Improved computer-aided detection performance for pulmonary embolism on CTPA with higher noise reduction reconstruction},
journal = {Emergency Radiology},
year = {2026},
volume = {33},
number = {5},
pages = {991--998},
doi = {10.1007/s10140-026-02500-3}
}
EUVIMED