EUVIMEDEUVIMED entdecken
BeobachtungsstudieVergleichsstudieOpen Access · CC BY 4.0

Photon-counting CT versus energy-integrating CT of the chest in acute respiratory distress syndrome: A retrospective observational study of image quality and radiation exposure

Daniel Rosok, Marcel Opitz, Denise Bos, Laura Klüner, Marcel Drews, Luca Salhöfer, Johannes Harmes, Nina Pirschtat, Simon Dubler, Michael Forsting, Johannes Haubold, Sebastian Zensen

Emergency Radiology · 13.05.2026 · 33 (4) · 833-843

DOI: 10.1007/s10140-026-02490-2 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Emergency Radiology, online erschienen am 13.05.2026. Verfasst von Daniel Rosok und 11 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, Essen, Germany. dan…. Hauptthemen laut MEDLINE: Respiratory Distress Syndrome, Tomography, X-Ray Computed, Radiography, Thoracic, Radiation Exposure. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Essen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Chest CT is central to the diagnosis and monitoring of acute respiratory distress syndrome (ARDS). Photon-counting detector CT (PCD-CT) may improve image quality and enable radiation dose optimization compared with Energy-integrating detector CT (EID-CT). However, evidence in critically ill ARDS patients undergoing contrast-enhanced chest imaging is limited. The purpose of this study was to intraindividually compare image quality and radiation exposure between PCD-CT and EID-CT in ARDS patients.

Methods

This retrospective study included patients with ARDS who underwent both contrast-enhanced chest PCD-CT and EID-CT between April 2023 and May 2025. CT dose index volume (CTDIvol), dose–length product (DLP), effective and organ doses were extracted from dose monitoring software. Subjective image quality and diagnostic acceptability were rated independently by two radiologists using a Likert scale; inter-reader agreement was assessed with Cohen’s κ. Objective image quality was assessed using signal-to-noise ratios in representative anatomical regions. Intraindividual comparisons were performed using the Wilcoxon signed-rank test.

Results

Among 531 ARDS patients, 80 (15.1%) underwent chest PCD-CT, including 59 (73.8%) contrast-enhanced examinations (median age: 51.7 years (IQR: 41.6–59.5); 62.7% male). Intraindividual imaging was performed in 32 patients (54.2%). PCD-CT demonstrated significantly higher subjective and objective image quality than EID-CT ( p < 0.005), with moderate inter-reader agreement. Median CTDIvol and DLP were not significantly different between PCD-CT (8.2 mGy; 435 mGycm) and EID-CT (7.7 mGy; 297 mGycm).

Conclusion

In contrast-enhanced chest CT of ARDS patients, PCD-CT provides superior image quality without a significant difference in radiation dose, potentially facilitating more precise diagnostic assessment in this critically ill population.

Trial registration

DRKS-ID: DRKS00037916, 15 September 2025, retrospectively registered.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Respiratory Distress SyndromeTomography, X-Ray ComputedRadiography, ThoracicRadiation ExposureHumansRetrospective StudiesMaleFemaleMiddle AgedRadiation DosageContrast MediaAgedAdult

Stichwörter der Autor:innen

Chest computed tomographyEffective doseLung injuryPhoton-counting detectorsRadiation dosage

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, Essen, Germany. daniel.rosok@uk-essen.de.
  • Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, Essen, Germany.
  • Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich, Switzerland.
  • Department of Anesthesiology and Intensive Care Medicine, University Hospital Essen, University of Duisburg-Essen, Essen, Germany.

Förderung

  • Universitätsklinikum Essen

Zitieren

APA

Rosok, D., Opitz, M., Bos, D., Klüner, L., Drews, M., Salhöfer, L., Harmes, J., Pirschtat, N., Dubler, S., Forsting, M., Haubold, J., & Zensen, S. (2026). Photon-counting CT versus energy-integrating CT of the chest in acute respiratory distress syndrome: A retrospective observational study of image quality and radiation exposure. Emergency Radiology, 33(4), 833-843. https://doi.org/10.1007/s10140-026-02490-2

Vancouver

Rosok D, Opitz M, Bos D, Klüner L, Drews M, Salhöfer L, et al. Photon-counting CT versus energy-integrating CT of the chest in acute respiratory distress syndrome: A retrospective observational study of image quality and radiation exposure. Emergency Radiology. 2026;33(4):833-843. doi:10.1007/s10140-026-02490-2

BibTeX
@article{Rosok2026,
  author = {Rosok, Daniel and Opitz, Marcel and Bos, Denise and Klüner, Laura and Drews, Marcel and Salhöfer, Luca and Harmes, Johannes and Pirschtat, Nina and Dubler, Simon and Forsting, Michael and Haubold, Johannes and Zensen, Sebastian},
  title = {Photon-counting CT versus energy-integrating CT of the chest in acute respiratory distress syndrome: A retrospective observational study of image quality and radiation exposure},
  journal = {Emergency Radiology},
  year = {2026},
  volume = {33},
  number = {4},
  pages = {833--843},
  doi = {10.1007/s10140-026-02490-2}
}
Kostenlos starten →