EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Single-sequence low-field 3D T1-weighted MRI for scaphoid fracture detection compared to radiography: prospective diagnostic accuracy pilot study

Claudia Neubauer, Christopher Schuppert, Carolin S Reidelbach, Horst Zajonc, Filip Simunovic, Sebastian M Goerke, Fabian Bamberg, Sebastian Wirtz, Maximilian F Russe, Thierno D Diallo, Jakob Neubauer

Emergency Radiology · 2026

DOI: 10.1007/s10140-026-02481-3 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Emergency Radiology, 2026. Verfasst von Claudia Neubauer und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg…. Hauptthemen laut MEDLINE: Scaphoid Bone, Magnetic Resonance Imaging, Fractures, Bone, Imaging, Three-Dimensional. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Freiburg.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To determine the diagnostic accuracy of a novel high-resolution 3D T1-weighted gradient-echo sequence in low-field MRI for detecting scaphoid fractures compared with radiography.

Methods

In this prospective single-center study, patients with suspected scaphoid injury underwent wrist radiography and 0.31 T extremity MRI including a 4-min 3D gradient-echo sequence (3D SST1). Three musculoskeletal radiologists independently evaluated radiographs and the isolated 3D sequence in separate sessions, rating fracture presence, displacement/stability, diagnostic confidence (five-point Likert scale), and need for additional imaging. The reference standard was based on CT and standard MRI sequences, evaluated by two experienced musculoskeletal radiologists.

Results

Forty patients with 11 scaphoid fractures were included. Across readers, AUC for scaphoid fracture detection was 1.000 for 3D MRI and 0.823 for radiography (AUC-difference 0.177, 95% CI: -0.004–0.359, p = 0.056). For 3D MRI, sensitivity and NPV were 1.000 for all readers. Specificity (0.931–0.966 vs 0.655–0.862) and PPV (0.846–0.917 vs 0.444–0.667) were higher than for radiography. Diagnostic confidence was excellent (median score 1) with near-perfect inter-rater agreement (κ = 0.961). Additional imaging was not recommended in 40/36/37 cases (reader 1/2/3).

Conclusion

A single 4-min high-resolution 3D low-field MRI sequence enabled highly accurate detection of scaphoid fractures with perfect sensitivity and NPV, a high reader confidence, and an improved performance compared to radiography in this small pilot cohort. This approach may facilitate rapid, radiation-free screening in acute wrist trauma.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Scaphoid BoneMagnetic Resonance ImagingFractures, BoneImaging, Three-DimensionalWrist FracturesHumansProspective StudiesPilot ProjectsFemaleMaleSensitivity and SpecificityAdultAdolescentMiddle Aged

Stichwörter der Autor:innen

Carpal traumaLow-field MRIMusculoskeletal MRIRadiographyScaphoid fracture

Autor:innen und Institutionen

  • Department of Diagnostic and Interventional Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg im Breisgau, Germany. claudia.neubauer@uniklinik-freiburg.de.
  • Department of Diagnostic and Interventional Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg im Breisgau, Germany.
  • Department of Hand and Plastic Surgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg im Breisgau, Germany.
  • , Stühlingerstr. 24, 79106, Freiburg, Germany.
  • Radiology Team, Lahr, Germany.

Förderung

  • Universitätsklinikum Freiburg

Zitieren

APA

Neubauer, C., Schuppert, C., Reidelbach, C. S., Zajonc, H., Simunovic, F., Goerke, S. M., Bamberg, F., Wirtz, S., Russe, M. F., Diallo, T. D., & Neubauer, J. (2026). Single-sequence low-field 3D T1-weighted MRI for scaphoid fracture detection compared to radiography: prospective diagnostic accuracy pilot study. Emergency Radiology. https://doi.org/10.1007/s10140-026-02481-3

Vancouver

Neubauer C, Schuppert C, Reidelbach CS, Zajonc H, Simunovic F, Goerke SM, et al. Single-sequence low-field 3D T1-weighted MRI for scaphoid fracture detection compared to radiography: prospective diagnostic accuracy pilot study. Emergency Radiology. 2026. doi:10.1007/s10140-026-02481-3

BibTeX
@article{Neubauer2026,
  author = {Neubauer, Claudia and Schuppert, Christopher and Reidelbach, Carolin S and Zajonc, Horst and Simunovic, Filip and Goerke, Sebastian M and Bamberg, Fabian and Wirtz, Sebastian and Russe, Maximilian F and Diallo, Thierno D and Neubauer, Jakob},
  title = {Single-sequence low-field 3D T1-weighted MRI for scaphoid fracture detection compared to radiography: prospective diagnostic accuracy pilot study},
  journal = {Emergency Radiology},
  year = {2026},
  doi = {10.1007/s10140-026-02481-3}
}
Kostenlos starten →