Comparative accuracy of photon-counting and dual energy CT pulmonary angiography perfusion mapping using V/Q scans as reference standard
Emergency Radiology · 25.04.2026 · 33 (4) · 743-753
DOI: 10.1007/s10140-026-02479-x ↗Kurz gefasst
Fachartikel in der Zeitschrift Emergency Radiology, online erschienen am 25.04.2026. Verfasst von Alexis Ogbonna und 7 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiothoracic Imaging, Department of Radiology, Medical University of South Carolina, 96 Jonathan Lucas Street Suite 210, MSC 323, Charl…. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medical University of South Carolina.
Abstract (Originalsprache)
To compare the diagnostic performance of photon-counting–detector CT (PCD-CT) and dual-energy CT (DECT) perfusion maps against ventilation–perfusion (V/Q) SPECT/CT as reference standard across diverse clinical indications, and to provide quantitative iodine density reference values. This retrospective study included two independent cohorts who underwent V/Q SPECT/CT and either PCD-CT or DECT. Lobar perfusion was assessed on each modality by two blinded readers with consensus serving as the reference for inter-reader agreement. Diagnostic accuracy, sensitivity, specificity, PPV, and NPV were calculated using V/Q SPECT/CT as the reference standard. Iodine density was measured using standardized regions of interest placed in normally perfused and hypoperfused lobes. Inter-reader agreement was evaluated using Cohen’s κ. Statistical comparisons were performed using paired or unpaired tests as appropriate, with significance set at p < 0.05. PCD-CT demonstrated an accuracy of 0.85, sensitivity of 0.71, specificity of 0.97, and κ of 0.80. DECT demonstrated an accuracy of 0.89, sensitivity of 0.52, specificity of 0.97, and κ of 0.59. Differences in diagnostic performance between PCD-CT and DECT were not statistically significant. Iodine density was significantly higher in normally perfused lung compared with perfusion defects for both PCD-CT (2.10±0.29 vs 0.40±0.18 mg/mL; p < 0.001) and DECT (2.30±0.29 vs 0.49±0.17 mg/mL; p < 0.001). Both PCD-CT and DECT provide high diagnostic accuracy for detecting lobar perfusion defects, with PCD-CT demonstrating higher inter-reader agreement. This study provides the first quantitative iodine reference values for PCD-CT pulmonary perfusion, supporting its potential as a robust functional complement to conventional CTPA.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Cardiothoracic Imaging, Department of Radiology, Medical University of South Carolina, 96 Jonathan Lucas Street Suite 210, MSC 323, Charleston, SC, 29425, USA.
- Division of Cardiothoracic Radiology, Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, USA.
- Division of Nuclear Medicine, Department of Radiology, Medical University of South Carolina, Charleston, SC, USA.
- Division of Cardiothoracic Imaging, Department of Radiology, Medical University of South Carolina, 96 Jonathan Lucas Street Suite 210, MSC 323, Charleston, SC, 29425, USA. kabakus@musc.edu.
Förderung
- Medical University of South Carolina
Zitieren
APA
Ogbonna, A., Chamberlin, J. H., Baruah, D., Rodriguez, C. L., Mencken, I., Burt, J. R., Elojeimy, S., & Kabakus, I. M. (2026). Comparative accuracy of photon-counting and dual energy CT pulmonary angiography perfusion mapping using V/Q scans as reference standard. Emergency Radiology, 33(4), 743-753. https://doi.org/10.1007/s10140-026-02479-x
Vancouver
Ogbonna A, Chamberlin JH, Baruah D, Rodriguez CL, Mencken I, Burt JR, et al. Comparative accuracy of photon-counting and dual energy CT pulmonary angiography perfusion mapping using V/Q scans as reference standard. Emergency Radiology. 2026;33(4):743-753. doi:10.1007/s10140-026-02479-x
BibTeX
@article{Ogbonna2026,
author = {Ogbonna, Alexis and Chamberlin, Jordan H and Baruah, Dhiraj and Rodriguez, Cesar Lopez and Mencken, Ian and Burt, Jeremy R and Elojeimy, Saeed and Kabakus, Ismail M},
title = {Comparative accuracy of photon-counting and dual energy CT pulmonary angiography perfusion mapping using V/Q scans as reference standard},
journal = {Emergency Radiology},
year = {2026},
volume = {33},
number = {4},
pages = {743--753},
doi = {10.1007/s10140-026-02479-x}
}
EUVIMED