EUVIMEDEUVIMED entdecken
Crossref

Off-console automated artificial intelligence enhanced workflow enables improved emergency department CT capacity

John McMenamy, Sergey Kochkine, Mark Bernstein, Anthony Lucero, Randy Miles, Adam Schwertner, Ashesh Thaker, David M Naeger

Emergency Radiology · 2024

DOI: 10.1007/s10140-024-02297-z ↗

Kurz gefasst

Fachartikel in der Zeitschrift Emergency Radiology, 2024. Verfasst von John McMenamy und 7 weiteren Autor:innen. Beteiligte Einrichtung: Denver Health Medical Center, Denver, USA. john.mcmenamy@dhha.org. Hauptthemen laut MEDLINE: Workflow, Emergency Service, Hospital, Tomography, X-Ray Computed, Artificial Intelligence. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 20 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Increasing CT capacity to keep pace with rising ED demand is critical. The conventional process has inherent drawbacks. We evaluated an off-console automated AI enhanced workflow which moves all final series creation off-console. We hypothesized the off-console workflow would 1) decrease overall ED CT exam begin to end times and decrease length and variability of time CT is occupied at the individual exam level. METHODS: Study population was identified retrospectively and included all CT exams done on all ED adult patients. 3 months of data was collected using the conventional workflow and 3 months of data was collected after implementation of the off-console workflow. Exam begin and the exam end timestamps were collected from the EMR. Additionally, 4 subgroups from the above conventional and off-console workflows were identified retrospectively with an Emergency Severity Index level 1, undergoing one of the four most common CT exam set(s) performed on ESI level 1 patients. RESULTS: 6,795 ED adult patients underwent ED CT in the 3 months immediately prior to implementation of the off-console workflow and 6,708 adult ED patients underwent CT in the 3 months after complete implementation. The off-console workflow demonstrated a 36% decrease in median exam begin to end times (P < 0.001). 4 subgroups demonstrated 56-75% decreases in median CT occupied time (P < 0.001) and decreases in variability in ¾ subgroups. DISCUSSION: This off-console workflow enables increased CT capacity to meet rising ED demand. Similar improvements could be expected across most exam sets and imaging settings if broadly implemented.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

WorkflowEmergency Service, HospitalTomography, X-Ray ComputedArtificial IntelligenceHumansRetrospective StudiesMaleFemaleAdultEfficiency, OrganizationalMiddle Aged

Stichwörter der Autor:innen

Artificial Intelligence (AI)AutomationCapacityComputed tomography (CT)Emergency Department (ED)

Autor:innen und Institutionen

  • Denver Health Medical Center, Denver, USA. john.mcmenamy@dhha.org.
  • Stony Brook University Hospital, Stony Brook, USA.
  • Boston Medical Center, Boston, USA.
  • Denver Health Medical Center, Denver, USA.
  • Dartmouth-Hitchcock Medical Center, Lebanon, USA.

Zitieren

APA

McMenamy, J., Kochkine, S., Bernstein, M., Lucero, A., Miles, R., Schwertner, A., Thaker, A., & Naeger, D. M. (2024). Off-console automated artificial intelligence enhanced workflow enables improved emergency department CT capacity. Emergency Radiology. https://doi.org/10.1007/s10140-024-02297-z

Vancouver

McMenamy J, Kochkine S, Bernstein M, Lucero A, Miles R, Schwertner A, et al. Off-console automated artificial intelligence enhanced workflow enables improved emergency department CT capacity. Emergency Radiology. 2024. doi:10.1007/s10140-024-02297-z

BibTeX
@article{McMenamy2024,
  author = {McMenamy, John and Kochkine, Sergey and Bernstein, Mark and Lucero, Anthony and Miles, Randy and Schwertner, Adam and Thaker, Ashesh and Naeger, David M},
  title = {Off-console automated artificial intelligence enhanced workflow enables improved emergency department CT capacity},
  journal = {Emergency Radiology},
  year = {2024},
  doi = {10.1007/s10140-024-02297-z}
}
Kostenlos starten →