Fachartikel in der Zeitschrift Emergency Radiology, 2024. Verfasst von Lindsey K Miley und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Mayo Clinic, Rochester, Minnesota, United States of America. Koop.Lindsey@mayo.edu. Hauptthemen laut MEDLINE: Arthritis, Infectious, Arthrocentesis, Synovial Fluid, Predictive Value of Tests. Die Arbeit nennt 9 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Septic arthritis is a dangerous medical condition requiring prompt diagnosis, often via arthrocentesis. A "dry tap" occurs when no fluid is aspirated. We hypothesized that the absence of a joint effusion on pre-procedure advanced imaging would reliably predict a dry tap and exclude septic arthritis. METHODS: A cohort of 217 arthrocentesis cases of large joints (hips, shoulders, knees) from our institution, with pre-procedure advanced imaging (CT, MR, US) of the same joint performed within the previous 48 h, was analyzed. Exclusion criteria included non-native joints or inadequate imaging of the affected joint. These cases underwent blinded review by 4 radiologists who measured the deepest pocket of joint fluid on the pre-procedure imaging. Wilcoxon rank-sum test was performed comparing joint fluid pocket size to outcomes of successful aspiration and final diagnosis. RESULTS: A smaller average joint pocket fluid size was present on advanced imaging in both dry taps compared with successful arthrocenteses (p < .0001), and in uninfected joints compared with septic joints (p = .0001). However, the overlap of values was too great to allow for a perfectly predictive cutoff. 29% (5/17) of patients with no visible joint fluid on pre-aspiration imaging underwent successful arthrocentesis, one case representing septic arthritis. CONCLUSION: Volume of joint fluid on advanced pre-arthrocentesis imaging cannot reliably predict subsequent dry tap nor exclude septic arthritis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthritis, InfectiousArthrocentesisSynovial FluidPredictive Value of TestsHumansMaleFemaleMiddle AgedAgedAdultRetrospective StudiesAged, 80 and over

Stichwörter der Autor:innen

ArthrocentesisAspirationJointSeptic

Autor:innen und Institutionen

  • Department of Radiology, Mayo Clinic, Rochester, Minnesota, United States of America. Koop.Lindsey@mayo.edu.
  • Department of Radiology, Mayo Clinic, Rochester, Minnesota, United States of America.

Zitieren

APA

Miley, L. K., Boyum, J. H., McDonald, J. S., Horst, K. K., Howe, B. M., & Ringler, M. D. (2024). Predictive value of joint fluid volume on advanced pre-procedure imaging related to success of arthrocentesis and presence of septic arthritis. Emergency Radiology. https://doi.org/10.1007/s10140-024-02244-y

Vancouver

Miley LK, Boyum JH, McDonald JS, Horst KK, Howe BM, Ringler MD. Predictive value of joint fluid volume on advanced pre-procedure imaging related to success of arthrocentesis and presence of septic arthritis. Emergency Radiology. 2024. doi:10.1007/s10140-024-02244-y

BibTeX
@article{Miley2024,
  author = {Miley, Lindsey K and Boyum, James H and McDonald, Jennifer S and Horst, Kelly K and Howe, Benjamin M and Ringler, Michael D},
  title = {Predictive value of joint fluid volume on advanced pre-procedure imaging related to success of arthrocentesis and presence of septic arthritis},
  journal = {Emergency Radiology},
  year = {2024},
  doi = {10.1007/s10140-024-02244-y}
}
Kostenlos starten →