Diagnosis of foreign body aspiration with ultralow-dose CT using a tin filter: a comparison study
Emergency Radiology · 2020-08 · 27 (4) · 399-404
DOI: 10.1007/s10140-020-01764-7 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Emergency Radiology, online erschienen am 09.03.2020. Verfasst von Lena Gordon und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Radiology, Astrid Lindgren Children's Hospital, Karolinska University Hospital, Stockholm, Sweden. Die Arbeit wurde bisher 34-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Karolinska Institute.
Abstract (Originalsprache)
Purpose
Suspected airway foreign body aspiration (FBA) is a common event in paediatric emergency units, especially in children under 3 years of age. It can be a life-threatening event if not diagnosed promptly and accurately. The purpose of this study is to compare the diagnostic performance of an ultralow-dose CT (DLP of around 1 mGycm) with that of conventional radiographic methods (fluoroscopy and chest radiography of the airways) in the diagnosis of FBA children’s airways.
Methods
Retrospective cross-sectional study. Data from 136 children were collected: 75 were examined with conventional radiographic methods and 61 with ultralow-dose CT. Effective doses were compared using independent t tests. The results of bronchoscopy, if performed, were used in creating contingency 2 × 2 tables to assess the diagnostic performance between modalities. An extra triple reading of all images was applied for this purpose.
Results
The effective doses used in the ultralow-dose CT examinations were lower compared with those in conventional methods ( p < 0.001). The median dose for CT was 0.04 mSv compared with 0.1 mSv for conventional methods. Sensitivity and specificity were higher for ultralow-dose CT than those for conventional methods (100% and 98% versus 33% and 96%) as were the positive and negative predicted values (90% and 100% versus 60% and 91%).
Conclusion
Ultralow-dose CT can be used as the imaging of choice in the diagnosis of airway FBA in emergency settings, thereby avoiding concerns about radiation doses and negative bronchoscopy outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Pediatric Radiology, Astrid Lindgren Children's Hospital, Karolinska University Hospital, Stockholm, Sweden.
- Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm, Sweden.
- Department of Clinical Science, Intervention and Technology, Karolinska Institutet, Stockholm, Sweden.
- Department of Pediatric Radiology, Astrid Lindgren Children's Hospital, Karolinska University Hospital, Stockholm, Sweden. Sandra.diaz-ruiz@sll.se.
- Department of Diagnostic Radiology, Skane University Hospital, Malmo, Sweden. Sandra.diaz-ruiz@sll.se.
Förderung
- Karolinska Institute
Zitieren
APA
Gordon, L., Nowik, P., Mobini Kesheh, S., Lidegran, M., & Diaz, S. (2020). Diagnosis of foreign body aspiration with ultralow-dose CT using a tin filter: a comparison study. Emergency Radiology, 27(4), 399-404. https://doi.org/10.1007/s10140-020-01764-7
Vancouver
Gordon L, Nowik P, Mobini Kesheh S, Lidegran M, Diaz S. Diagnosis of foreign body aspiration with ultralow-dose CT using a tin filter: a comparison study. Emergency Radiology. 2020;27(4):399-404. doi:10.1007/s10140-020-01764-7
BibTeX
@article{Gordon2020,
author = {Gordon, Lena and Nowik, Patrik and Mobini Kesheh, Shahla and Lidegran, Marika and Diaz, Sandra},
title = {Diagnosis of foreign body aspiration with ultralow-dose CT using a tin filter: a comparison study},
journal = {Emergency Radiology},
year = {2020},
volume = {27},
number = {4},
pages = {399--404},
doi = {10.1007/s10140-020-01764-7}
}
EUVIMED