Evaluation of cutting accuracy and thermal damage in oral soft tissue using different surgical techniques

Abdukhamidjon Azimov, Muhammad Aidil Roslan, Noor Azlin Yahya, Anand Ramanathan, Harith Ahmad, Zamri Radzi

Lasers in Medical Science · 2025

DOI: 10.1007/s10103-025-04737-9 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Lasers in Medical Science, 2025. Verfasst von Abdukhamidjon Azimov und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, Paediatric and Special Care Dentistry, Faculty of Dentistry, Universiti Malaya, Kuala Lumpur, Malaysia. Hauptthemen laut MEDLINE: Mouth Mucosa, Laser Therapy. Die Arbeit nennt 41 Literaturangaben. Gefördert von: Ministry of Economy, Malaysia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To evaluate the cutting accuracy and thermal damage in oral soft tissue using different cutting techniques. Sixty specimens of sheep oral mucosa tissue, with the dimensions of 2.0 cm in length and 1.5 cm in width were prepared and divided into six groups (n = 10) representing different cutting technique. Incisions were made by sectioning each specimen using the 2000 nm continuous-wave (CW) silica based thulium-doped fibre (TDF) laser (Group A), the 1550 nm CW silica based Erbium/Ytterbium-doped fibre (EYDF) laser (Group B), electrosurgery (Group C), 980 nm diode laser (Group D), 2000 nm ultrashort-pulsed (USP) silica based TDF laser (Group E), and the scalpel (Group F or control group). Each specimen was measured for average roughness value (Ra) and thermal damage, reported as mean and standard deviation. A one-way ANOVA with post-hoc Tukey's HSD test was performed to determine significant differences among six groups, with a significance level set at p < 0.05. Among the energy-based groups, the 2000 nm USP silica based TDF laser (Group E) exhibited the lowest Ra (1.22 ± 0.71 μm) and minimal thermal damage (9.85 ± 4.01%). In contrast, the highest Ra (4.82 ± 1.36 μm) was observed in the electrosurgery (Group C), while the highest thermal damage (16.73 ± 4.57%) was recorded in the 1550 nm CW silica based EYDF laser (Group B). One-way ANOVA revealed statistically significant differences among the groups in both average roughness (F = 45.45, p < 0.001) and thermal damage (F = 11.84, p < 0.001). The findings suggest that the 2000 nm USP silica based TDF laser offers superior cutting accuracy with minimal impact of thermal damage, supporting its potential adoption into clinical protocols for oral soft tissue surgery.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Mouth MucosaLaser TherapyAnimalsSheepElectrosurgeryLasers, Solid-StateLasers, Semiconductor

Stichwörter der Autor:innen

1550 nm CW silica based EYDF laser2000 nm CW silica based TDF laser2000 nm USP silica based TDF laser980 nm diode laserCutting accuracyOral mucosa tissueThermal damage

Autor:innen und Institutionen

  • Department of Orthodontics, Paediatric and Special Care Dentistry, Faculty of Dentistry, Universiti Malaya, Kuala Lumpur, Malaysia.
  • Department of Science and Technology Studies, Faculty of Science, Universiti Malaya, Kuala Lumpur, Malaysia.
  • Department of Restorative Dentistry, Faculty of Dentistry, Universiti Malaya, Kuala Lumpur, Malaysia.
  • Department of Oral and Maxillofacial Clinical Sciences, Faculty of Dentistry, Universiti Malaya, Kuala Lumpur, Malaysia.
  • Photonics Research Centre, Universiti Malaya, Kuala Lumpur, Malaysia.
  • Department of Orthodontics, Paediatric and Special Care Dentistry, Faculty of Dentistry, Universiti Malaya, Kuala Lumpur, Malaysia. zamrir@um.edu.my.

Förderung

  • Ministry of Economy, Malaysia

Zitieren

APA

Azimov, A., Roslan, M. A., Yahya, N. A., Ramanathan, A., Ahmad, H., & Radzi, Z. (2025). Evaluation of cutting accuracy and thermal damage in oral soft tissue using different surgical techniques. Lasers in Medical Science. https://doi.org/10.1007/s10103-025-04737-9

Vancouver

Azimov A, Roslan MA, Yahya NA, Ramanathan A, Ahmad H, Radzi Z. Evaluation of cutting accuracy and thermal damage in oral soft tissue using different surgical techniques. Lasers in Medical Science. 2025. doi:10.1007/s10103-025-04737-9

BibTeX
@article{Azimov2025,
  author = {Azimov, Abdukhamidjon and Roslan, Muhammad Aidil and Yahya, Noor Azlin and Ramanathan, Anand and Ahmad, Harith and Radzi, Zamri},
  title = {Evaluation of cutting accuracy and thermal damage in oral soft tissue using different surgical techniques},
  journal = {Lasers in Medical Science},
  year = {2025},
  doi = {10.1007/s10103-025-04737-9}
}
Kostenlos starten →