EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Reverse confocal polarized Raman spectroscopy (RCPRS) for tissue analysis

Khan Mohammad Khan, Amrita Srivastava, Surjendu Bikash Dutta, Nitin Kumar, Shovan Kumar Majumder

Lasers in Medical Science · 2025

DOI: 10.1007/s10103-025-04462-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Lasers in Medical Science, 2025. Verfasst von Khan Mohammad Khan und 4 weiteren Autor:innen. Beteiligte Einrichtung: Raja Ramanna Centre for Advanced Technology, Indore, India. khanmdkhan@rrcat.gov.in. Hauptthemen laut MEDLINE: Spectrum Analysis, Raman. Die Arbeit nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Raja Ramanna Centre for Advanced Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Confocal Raman spectroscopy (CRS) being one of the most widely used depth-sensitive techniques for measuring layer wise Raman characteristics of layered biological tissues faces two practical problems. First, the overall probing depth is limited in a given optical design of the CRS system and second, the objective lens used for focusing touches to surface of the target sample during probing of deeper sub-surface layers. To facilitate deeper probing in a given CRS system and to avoid lens-sample touching issue, an alternate scheme of depth-sensitive Raman measurement is presented. The scheme, named reverse confocal polarized Raman spectroscopy (RCPRS), uses an experimental arrangement of plane polarized illumination and orthogonal polarized detection in which depth-sensitive measurements are performed by moving the focal plane of the illumination beam away from the tissue surface unlike to CRS which obtains depth-separation by traversing across different depths of the target tissue. The performance of the RCPRS is evaluated using a non-biological phantom and a biological tissue. It is found that the introduction of polarization reduces the interference of the signals originating from the layers surrounding the target layer and thereby improving the depth-selectivity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Spectrum Analysis, RamanPhantoms, ImagingHumans

Stichwörter der Autor:innen

Confocal detectionMultiple scatteringReverse confocal polarized Raman spectroscopyThin layered samples

Autor:innen und Institutionen

  • Raja Ramanna Centre for Advanced Technology, Indore, India. khanmdkhan@rrcat.gov.in.
  • Raja Ramanna Centre for Advanced Technology, Indore, India.
  • Homi Bhabha National Institute (HBNI), Training School Complex, Mumbai, India.

Förderung

  • Raja Ramanna Centre for Advanced Technology

Zitieren

APA

Khan, K. M., Srivastava, A., Dutta, S. B., Kumar, N., & Majumder, S. K. (2025). Reverse confocal polarized Raman spectroscopy (RCPRS) for tissue analysis. Lasers in Medical Science. https://doi.org/10.1007/s10103-025-04462-3

Vancouver

Khan KM, Srivastava A, Dutta SB, Kumar N, Majumder SK. Reverse confocal polarized Raman spectroscopy (RCPRS) for tissue analysis. Lasers in Medical Science. 2025. doi:10.1007/s10103-025-04462-3

BibTeX
@article{Khan2025,
  author = {Khan, Khan Mohammad and Srivastava, Amrita and Dutta, Surjendu Bikash and Kumar, Nitin and Majumder, Shovan Kumar},
  title = {Reverse confocal polarized Raman spectroscopy (RCPRS) for tissue analysis},
  journal = {Lasers in Medical Science},
  year = {2025},
  doi = {10.1007/s10103-025-04462-3}
}
Kostenlos starten →