Thulium fiber laser versus pulsed Thulium:YAG for laser lithotripsy during flexible ureteroscopy
Lasers in Medical Science · 2024
DOI: 10.1007/s10103-024-04267-w ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Lasers in Medical Science, 2024. Verfasst von Frédéric Panthier und 7 weiteren Autor:innen. Beteiligte Einrichtung: Groupe de Recherche Clinique sur la Lithiase Urinaire, GRC n°20, Hôpital Tenon, Sorbonne Université, Paris, 75020, France. fredericpanthier@gmail.com. Hauptthemen laut MEDLINE: Lithotripsy, Laser, Ureteroscopy, Thulium, Lasers, Solid-State. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 40 Literaturangaben.
Abstract (Originalsprache)
To compare the pulsed-Thulium: YAG(p-Tm: YAG) and Thulium Fiber(TFL) lasers in terms of efficiency and safety profiles during flexible ureteroscopy(fURS) and endocorporeal laser lithotripsy(ELL). A prospective single-center open-label comparative study included consecutive patients with ureteral and renal stones who underwent fURS using Thulio(p-Tm: YAG, Dornier©,Germany) or TFL Drive(TFL, Coloplast©,Danemark), with 270 μm and 150/200μm laser fibers(LF), respectively. fURS were performed by a single operator in each group. Demographics, stone size, stone density, laser-on time(LOT) and laser settings were recorded. Ablation speed(mm3/s), energy consumption(J/mm3) values for each procedure were also assessed. Stone-free rate(SFR,
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Groupe de Recherche Clinique sur la Lithiase Urinaire, GRC n°20, Hôpital Tenon, Sorbonne Université, Paris, 75020, France. fredericpanthier@gmail.com.
- Service d'Urologie, Assistance-Publique Hôpitaux de Paris, Hôpital Tenon, Sorbonne Université, 4 rue de la Chine, Paris, 75020, France. fredericpanthier@gmail.com.
- PIMM, UMR 8006 CNRS-Arts et Métiers ParisTech, 151 bd de l'Hôpital, Paris, F-75013, France. fredericpanthier@gmail.com.
- Progressive Endourological Association for Research and Leading Solutions (PEARLS group), Paris, France. fredericpanthier@gmail.com.
- Groupe de Recherche Clinique sur la Lithiase Urinaire, GRC n°20, Hôpital Tenon, Sorbonne Université, Paris, 75020, France.
- Service d'Urologie, Assistance-Publique Hôpitaux de Paris, Hôpital Tenon, Sorbonne Université, 4 rue de la Chine, Paris, 75020, France.
Zitieren
APA
Panthier, F., Solano, C., Chicaud, M., Kutchukian, S., Candela, L., Doizi, S., Corrales, M., & Traxer, O. (2024). Thulium fiber laser versus pulsed Thulium:YAG for laser lithotripsy during flexible ureteroscopy. Lasers in Medical Science. https://doi.org/10.1007/s10103-024-04267-w
Vancouver
Panthier F, Solano C, Chicaud M, Kutchukian S, Candela L, Doizi S, et al. Thulium fiber laser versus pulsed Thulium:YAG for laser lithotripsy during flexible ureteroscopy. Lasers in Medical Science. 2024. doi:10.1007/s10103-024-04267-w
BibTeX
@article{Panthier2024,
author = {Panthier, Frédéric and Solano, Catalina and Chicaud, Marie and Kutchukian, Stessy and Candela, Luigi and Doizi, Steeve and Corrales, Mariela and Traxer, Olivier},
title = {Thulium fiber laser versus pulsed Thulium:YAG for laser lithotripsy during flexible ureteroscopy},
journal = {Lasers in Medical Science},
year = {2024},
doi = {10.1007/s10103-024-04267-w}
}
EUVIMED