VirClia® chemiluminescent assays as a tool for detecting Bartonella Henselae and Coxiella burnetii infections
European Journal of Clinical Microbiology & Infectious Diseases · 2025
DOI: 10.1007/s10096-025-05223-4 ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift European Journal of Clinical Microbiology & Infectious Diseases, 2025. Verfasst von Jordi Tortosa-Carreres und 11 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory Department, Hospital Univeritari i Politècnic la Fe, Av Fernando Abril Martorell 106, València, 46026, Spain. jorditc95@outlook.com. Hauptthemen laut MEDLINE: Coxiella burnetii, Bartonella henselae, Q Fever, Antibodies, Bacterial. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 39 Literaturangaben.
Abstract (Originalsprache)
INTRODUCTION: VirClia® provides an automated platform for detecting antibodies against Bartonella henselae and Coxiella burnetii. OBJECTIVE: To assess the diagnostic performance of VirClia® and identify potential sources of interference. METHODS: A retrospective study was conducted using two independent datasets from routine clinical samples tested simultaneously by IFA and VirClia®. Diagnostic performance was evaluated using Cohen's kappa and ROC curves, with IFA as the reference standard. For C. burnetii (n=1628), IgG against Phase I, Phase II, and their combination (positive if either reactive) was analyzed. For B. henselae (n=955), IgG and IgM were assessed independently. Two thresholds were defined per parameter: one ensuring 90% sensitivity and another ≥90% specificity. Intermediate values were considered within a gray zone, assumed to require IFA confirmation. The potential reduction in IFA use was estimated assuming that values outside this zone would not need confirmation. False positives (FP) were defined as VirClia® values above the high-specificity threshold with a negative IFA result. Logistic regression was used to assess associations between FP results and sex, age, and symptoms. The presence of autoantibodies in FP cases was also evaluated. RESULTS: Applying gray zone thresholds-using the manufacturer's upper cut-off (1.1) and a sensitivity-driven lower limit-yielded estimated IFA reductions of 56% for B. henselae IgG, 42% for IgM, and 79% for C. burnetii (combined phases). FP results for C. burnetii were significantly associated with extractable nuclear antigens and older age. CONCLUSION: VirClia® demonstrates strong diagnostic performance and may reduce IFA dependency when a gray zone strategy is implemented.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Laboratory Department, Hospital Univeritari i Politècnic la Fe, Av Fernando Abril Martorell 106, València, 46026, Spain. jorditc95@outlook.com.
- Microbiology Department, Hospital Univeritari i Politècnic la Fe, Av Fernando Abril Martorell 106, València, 46026, Spain.
- Microbiology Department, Hospital General de Fuerteventura Virgen de la Peña, Carretera del Aeropuerto, Km 1, Puerto del Rosario, Fuerteventura, 35600, Spain. wadjur@hotmail.com.
- Laboratory Department, Hospital Univeritari i Politècnic la Fe, Av Fernando Abril Martorell 106, València, 46026, Spain.
Zitieren
APA
Tortosa-Carreres, J., Lloret-Sos, C., Sahuquillo-Arce, J. M., Garrido-Jareño, M., Fornals-López, A., Pérez-Cataldo, G., Alba-Redono, A., Martínez-Triguero, M. L., Aguado-Codina, C., Pascual-Costa, R. M., Laiz-Marro, B., & López-Hontangas, J. L. (2025). VirClia® chemiluminescent assays as a tool for detecting Bartonella Henselae and Coxiella burnetii infections. European Journal of Clinical Microbiology & Infectious Diseases. https://doi.org/10.1007/s10096-025-05223-4
Vancouver
Tortosa-Carreres J, Lloret-Sos C, Sahuquillo-Arce JM, Garrido-Jareño M, Fornals-López A, Pérez-Cataldo G, et al. VirClia® chemiluminescent assays as a tool for detecting Bartonella Henselae and Coxiella burnetii infections. European Journal of Clinical Microbiology & Infectious Diseases. 2025. doi:10.1007/s10096-025-05223-4
BibTeX
@article{TortosaCarreres2025,
author = {Tortosa-Carreres, Jordi and Lloret-Sos, Carmen and Sahuquillo-Arce, Jose Miguel and Garrido-Jareño, Marta and Fornals-López, Ana and Pérez-Cataldo, Gabriela and Alba-Redono, Amparo and Martínez-Triguero, María Luisa and Aguado-Codina, Cristina and Pascual-Costa, Rosa María and Laiz-Marro, Begoña and López-Hontangas, Jose Luis},
title = {VirClia® chemiluminescent assays as a tool for detecting Bartonella Henselae and Coxiella burnetii infections},
journal = {European Journal of Clinical Microbiology & Infectious Diseases},
year = {2025},
doi = {10.1007/s10096-025-05223-4}
}
EUVIMED