EUVIMEDEUVIMED entdecken
VergleichsstudieEvaluationsstudieOpen Access · CC BY 4.0

A novel comparative evaluation of multiplex PCR panels for gastrointestinal pathogen detection: Seegene Allplex™ vs. Luminex NxTAG® in clinical stool samples

Laura Seijas-Pereda iD, Ana Martín, Raquel Menchero, Carlos Rescalvo-Casas iD, Marcos Hernando-Gozalo iD, Juan Cuadros-González iD, Ramón Pérez-Tanoira iD

European Journal of Clinical Microbiology & Infectious Diseases · 2025

DOI: 10.1007/s10096-025-05098-5 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift European Journal of Clinical Microbiology & Infectious Diseases, 2025. Verfasst von Laura Seijas-Pereda und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedicine and Biotechnology, Faculty of Medicine, University of Alcalá, Alcalá de Henares, Spain. laura.seijas@edu.uah.es. Hauptthemen laut MEDLINE: Multiplex Polymerase Chain Reaction, Feces, Molecular Diagnostic Techniques, Gastrointestinal Diseases. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universidad de Alcalá.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Accurate and rapid diagnosis of gastrointestinal infections is essential for effective patient management. This study compared the diagnostic performance of two multiplex PCR panels— the Seegene Allplex™ Gastrointestinal Panels (Seegene, Seoul, Korea) and the Luminex NxTAG ® Gastrointestinal Pathogen Panel (Luminex Corporation, Austin, Texas, a Diasorin Company)—in detecting gastrointestinal pathogens from clinical stool samples.

Methods

A total of 196 stool samples, collected from patients at a Spanish hospital during 2023, were analyzed using both assays through prospective and retrospective approaches. The performance of each test was assessed based on Positive Percentage Agreement (PPA), Negative Percentage Agreement (NPA), and overall agreement. Discrepancies between methods were resolved with a third confirmatory technique when available.

Results

Both assays demonstrated high overall concordance, with NPA values consistently above 95% and overall Kappa values exceeding 0.8 for most pathogens. The average PPA was greater than 89% for nearly all targets; however, lower agreement was observed for Cryptosporidium spp. (86.6%). Notably, discrepancies were primarily observed for certain pathogens, such as Salmonella spp. and Cryptosporidium spp. , highlighting the diagnostic challenges associated with these targets.

Conclusion

To our knowledge, this is the first study to compare the novel Luminex NxTAG ® panels from Diasorin with the Seegene Allplex™. Both multiplex assays provide rapid and reliable detection of gastrointestinal pathogens, making them valuable tools in clinical diagnostics. Future research should focus on improving detection accuracy for challenging pathogens and expanding target panels to further enhance patient management and reduce disease burden.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Multiplex Polymerase Chain ReactionFecesMolecular Diagnostic TechniquesGastrointestinal DiseasesHumansProspective StudiesRetrospective StudiesSensitivity and SpecificityFemaleMaleAdultMiddle AgedChildChild, PreschoolAgedCryptosporidiumYoung Adult

Stichwörter der Autor:innen

Healthcare impactLaboratory diagnosticsMolecular assayPositive percentage agreement and negative percentage agreementSyndromic testing

Autor:innen und Institutionen

  • Department of Biomedicine and Biotechnology, Faculty of Medicine, University of Alcalá, Alcalá de Henares, Spain. laura.seijas@edu.uah.es.
  • Department of Microbiology, Príncipe de Asturias University Hospital, Alcalá de Henares, Spain. laura.seijas@edu.uah.es.
  • Diasorin Iberia S.A, Alcobendas, Spain.
  • Department of Biomedicine and Biotechnology, Faculty of Medicine, University of Alcalá, Alcalá de Henares, Spain.
  • Department of Microbiology, Príncipe de Asturias University Hospital, Alcalá de Henares, Spain.
  • Department of Organic and Inorganic Chemistry, University of Alcalá, Alcalá de Henares, Spain.

ORCID-Profile: Laura Seijas-Pereda, Carlos Rescalvo-Casas, Marcos Hernando-Gozalo, Juan Cuadros-González, Ramón Pérez-Tanoira

Förderung

  • Universidad de Alcalá

Zitieren

APA

Seijas-Pereda, L., Martín, A., Menchero, R., Rescalvo-Casas, C., Hernando-Gozalo, M., Cuadros-González, J., & Pérez-Tanoira, R. (2025). A novel comparative evaluation of multiplex PCR panels for gastrointestinal pathogen detection: Seegene Allplex™ vs. Luminex NxTAG® in clinical stool samples. European Journal of Clinical Microbiology & Infectious Diseases. https://doi.org/10.1007/s10096-025-05098-5

Vancouver

Seijas-Pereda L, Martín A, Menchero R, Rescalvo-Casas C, Hernando-Gozalo M, Cuadros-González J, et al. A novel comparative evaluation of multiplex PCR panels for gastrointestinal pathogen detection: Seegene Allplex™ vs. Luminex NxTAG® in clinical stool samples. European Journal of Clinical Microbiology & Infectious Diseases. 2025. doi:10.1007/s10096-025-05098-5

BibTeX
@article{SeijasPereda2025,
  author = {Seijas-Pereda, Laura and Martín, Ana and Menchero, Raquel and Rescalvo-Casas, Carlos and Hernando-Gozalo, Marcos and Cuadros-González, Juan and Pérez-Tanoira, Ramón},
  title = {A novel comparative evaluation of multiplex PCR panels for gastrointestinal pathogen detection: Seegene Allplex™ vs. Luminex NxTAG® in clinical stool samples},
  journal = {European Journal of Clinical Microbiology & Infectious Diseases},
  year = {2025},
  doi = {10.1007/s10096-025-05098-5}
}
Kostenlos starten →