Impact of the microscopic quality of endotracheal aspirates on the performance of the Filmarray® pneumonia plus panel in intensive care unit patients with suspected lower respiratory tract infection
European Journal of Clinical Microbiology & Infectious Diseases · 2025
DOI: 10.1007/s10096-024-04967-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Clinical Microbiology & Infectious Diseases, 2025. Verfasst von Sofía Cano und 7 weiteren Autor:innen. Beteiligte Einrichtung: Microbiology Service, Clinic University Hospital, INCLIVA Health Research Institute, Av. Blasco Ibáñez 17, Valencia, 46010, Spain. Hauptthemen laut MEDLINE: Respiratory Tract Infections, Trachea, Bacteria, Molecular Diagnostic Techniques. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 16 Literaturangaben.
Themen: Intensivpflege
Abstract (Originalsprache)
PURPOSE: We investigated how the microscopic quality of endotracheal aspirates (ETA) impacts the performance of the Filmarray® pneumonia plus panel (FA-PP) in patients undergoing mechanical ventilation (IMV) with suspicion of lower respiratory tract bacterial infection (LRTBI). METHODS: The quality of ETA was categorized according to the number of leukocytes and buccal squamous epithelial (BSE)/field (100x magnification). G5 ( 25 leukocytes/field) and G4 (10-25 BSE cells and > 25 leukocytes/field) ETA were tested in parallel by the FA-PP and conventional semiquantitative culture. RESULTS: In total, 153 ETA were graded as G5 (from 115 patients) and 56 as G4 (from 48 patients). Focusing on "conventional" bacterial species, a trend towards more positive results (P = 0.16), and co-detections (P = 0.18) was returned by G5 ETA. Although more targets were detected on G5 ETA (P = 0.005), the spectra of bacteria detected was comparable across G5 and G4 specimens. A trend towards higher bacterial burdens as quantitated by the FA-PP, and irrespective of the target, was observed in G5 (median, 106 genome copies/ml) vs. G4 ETA (median, 105 genome copies/ml). The degree of full agreement between FA-PP and culture was higher for G5 ETA (Kappa value, 0.54; 95% CI, 0.43-0.66) than for G4 ETA (Kappa value, 0.31; 95% CI, 0.11-0.49). For all bacterial targets detected, genome copy/ml numbers exceeded colony forming units (CFU)/ml counts in 1-2 log10, irrespective of ETA grading. The degree of correlation between genome copies/ml and CFU/ml was slightly better for G5 ETA (Rho = 0.65; P = 0.001) than for G4 ETA (Rho = 0.54; P = 0.11). CONCLUSION: FA-PP testing of G5 ETA may provide more comprehensive and clinically useful information compared with G4 specimens in patients undergoing IMV with suspected LRTBI and receiving antimicrobial therapy. Yet G4 ETA may still provide useful microbiological information.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Microbiology Service, Clinic University Hospital, INCLIVA Health Research Institute, Av. Blasco Ibáñez 17, Valencia, 46010, Spain.
- Medical Intensive Care Unit, Clinic University Hospital, INCLIVA Health Research Institute, Valencia, Spain.
- Microbiology Service, Clinic University Hospital, INCLIVA Health Research Institute, Av. Blasco Ibáñez 17, Valencia, 46010, Spain. David.navarro@uv.es.
- CIBER de Enfermedades Infecciosas, Instituto de Salud Carlos III, Madrid, Spain. David.navarro@uv.es.
- Department of Microbiology, School of Medicine, University of Valencia, Valencia, Spain. David.navarro@uv.es.
Zitieren
APA
Cano, S., de Michelena, P., Clari, M. Á., Liñan, J., Olea, B., Torres, I., Carbonell, N., & Navarro, D. (2025). Impact of the microscopic quality of endotracheal aspirates on the performance of the Filmarray® pneumonia plus panel in intensive care unit patients with suspected lower respiratory tract infection. European Journal of Clinical Microbiology & Infectious Diseases. https://doi.org/10.1007/s10096-024-04967-9
Vancouver
Cano S, de Michelena P, Clari MÁ, Liñan J, Olea B, Torres I, et al. Impact of the microscopic quality of endotracheal aspirates on the performance of the Filmarray® pneumonia plus panel in intensive care unit patients with suspected lower respiratory tract infection. European Journal of Clinical Microbiology & Infectious Diseases. 2025. doi:10.1007/s10096-024-04967-9
BibTeX
@article{Cano2025,
author = {Cano, Sofía and de Michelena, Paula and Clari, Mª Ángeles and Liñan, Jorge and Olea, Beatriz and Torres, Ignacio and Carbonell, Nieves and Navarro, David},
title = {Impact of the microscopic quality of endotracheal aspirates on the performance of the Filmarray® pneumonia plus panel in intensive care unit patients with suspected lower respiratory tract infection},
journal = {European Journal of Clinical Microbiology & Infectious Diseases},
year = {2025},
doi = {10.1007/s10096-024-04967-9}
}
EUVIMED