Kurz gefasst

Fachartikel in der Zeitschrift Virtual Reality, online erschienen am 16.11.2026. Verfasst von Yixuan He und 5 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of New South Wales.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Tracking foot motion is critically beneficial for a wide range of applications, from immersive entertainment through to gamified rehabilitation. This study investigated the accuracy of the HTC VIVE Ultimate Tracker against the Vicon motion capture system during human walking. Ten healthy participants (aged 24–44 years) walked on a treadmill at four speeds (0.5 m/s, 1.0 m/s, 1.5 m/s, and 2.0 m/s) while tracking both feet and the pelvis. Agreement between the two systems was evaluated using a linear mixed model, Bland–Altman plots, and concordance correlation coefficients (CCC). Absolute errors ranged from millimetre- to centimetre-level. Linear mixed model (speed × tracker location × movement direction) indicated that absolute errors increased with gait speed. Foot trackers exhibited larger errors than the sacrum location, with greater errors in the medio-lateral and anterior–posterior directions compared to the vertical direction ( p < 0.001). Bland–Altman analyses revealed widening limits of agreement at different speeds (e.g., left foot, anterior–posterior direction: − 20.09 to 20.20 mm at 0.5 m/s, − 29.97 to 27.80 mm at 2.0 m/s). Ultimate Trackers demonstrated almost perfect agreement (CCC: > 0.99) for sacrum tracking and substantial agreement for foot tracking (CCC: > 0.98). These findings highlight the Ultimate Trackers’ potential as cost-effective alternatives for the analysis of human movement, demonstrating research- and clinical-grade performance for sacrum and foot tracking during normal gait speeds (≤ 1.5 m/s). However, the finding that accuracy declined at the 2.0 m/s speed, particularly for foot trajectories and in the anterior–posterior direction, indicates the need for technical refinements for higher-speed movements.

Förderung

  • University of New South Wales

Zitieren

APA

He, Y., Brodie, M. A., Kim, J., Humburg, P., Lord, S. R., & Okubo, Y. (2026). Validation of the HTC VIVE Ultimate Trackers compared with the Vicon motion capture system at slow, moderate and fast gait speeds. Virtual Reality. https://doi.org/10.1007/s10055-026-01541-w

Vancouver

He Y, Brodie MA, Kim J, Humburg P, Lord SR, Okubo Y. Validation of the HTC VIVE Ultimate Trackers compared with the Vicon motion capture system at slow, moderate and fast gait speeds. Virtual Reality. 2026. doi:10.1007/s10055-026-01541-w

BibTeX
@article{He2026,
  author = {He, Yixuan and Brodie, Matthew A. and Kim, Juno and Humburg, Peter and Lord, Stephen R. and Okubo, Yoshiro},
  title = {Validation of the HTC VIVE Ultimate Trackers compared with the Vicon motion capture system at slow, moderate and fast gait speeds},
  journal = {Virtual Reality},
  year = {2026},
  doi = {10.1007/s10055-026-01541-w}
}
Kostenlos starten →