EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparative evaluation of virtual reality setups for assessing cervical range of motion: a reliability study

José Angel Santos-Paz, Rodrigo García-Carmona, Álvaro Sánchez-Picot, Abraham Otero

Virtual Reality · 28.12.2025 · 30 (1)

DOI: 10.1007/s10055-025-01299-7 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Virtual Reality, online erschienen am 28.12.2025. Verfasst von José Angel Santos-Paz und 3 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministerio de Ciencia e Innovación.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cervical pain is a highly prevalent musculoskeletal condition, affecting an estimated 222 million people globally. There is a clear need for novel technologies that enable more accessible and affordable care delivery for this population. Assessing the Cervical Range of Motion (CROM) of the patient is a necessary step before designing a treatment plan, and periodically during treatment to monitor patient progress. This study analyzes the use of three VR setups (HTC Vive Pro Eye, HP Reverb G2, and Meta Quest 2) for CROM assessment, representing high-end, mid-range, and low-end devices. 94 individual assessment sessions were conducted by the same rater using a custom-designed VR application. This application simulates a medical environment and guides users through the required neck movements while storing tracking data for later analysis. Intra-rater reliability, measured by the Intraclass Correlation Coefficient, ranged from good to excellent for all setups: 0.81 $$-$$ 0.96 for HTC Vive Pro Eye, 0.92 $$-$$ 0.93 for Meta Quest 2, and 0.89 $$-$$ 0.94 for HP Reverb G2. The low-cost options presented slightly higher ICC than the high-end setup, although this difference was not statistically significant. The HMD physical design, weight distribution, and gripping mechanisms had a larger impact on the reliability than the tracking technology used. An anonymous survey showed high usability scores for all three devices. These findings support VR technology as a reliable and user-friendly tool for CROM assessment and show that low-cost devices can be used without compromising reliability or usability.

Förderung

  • Ministerio de Ciencia e Innovación

Zitieren

APA

Santos-Paz, J. A., García-Carmona, R., Sánchez-Picot, Á., & Otero, A. (2025). Comparative evaluation of virtual reality setups for assessing cervical range of motion: a reliability study. Virtual Reality, 30(1). https://doi.org/10.1007/s10055-025-01299-7

Vancouver

Santos-Paz JA, García-Carmona R, Sánchez-Picot Á, Otero A. Comparative evaluation of virtual reality setups for assessing cervical range of motion: a reliability study. Virtual Reality. 2025;30(1). doi:10.1007/s10055-025-01299-7

BibTeX
@article{SantosPaz2025,
  author = {Santos-Paz, José Angel and García-Carmona, Rodrigo and Sánchez-Picot, Álvaro and Otero, Abraham},
  title = {Comparative evaluation of virtual reality setups for assessing cervical range of motion: a reliability study},
  journal = {Virtual Reality},
  year = {2025},
  volume = {30},
  number = {1},
  doi = {10.1007/s10055-025-01299-7}
}
Kostenlos starten →