EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Fouling process of hemodiafiltration membranes by hemodialysis and hemodiafiltration therapy

Yoshihiro Tange, Masashi Kawakami, Shingo Takesawa

Journal of Artificial Organs · 2025

DOI: 10.1007/s10047-025-01497-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Artificial Organs, 2025. Verfasst von Yoshihiro Tange und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Advanced Medical Sciences, Faculty of Medicine, Oita University, 1-1 Idaigaoka, Hasama-Machi, Yufu, Oita, 879-5593, Japan. ytange@oita-…. Hauptthemen laut MEDLINE: Membranes, Artificial, Hemodiafiltration, Renal Dialysis, Biofouling. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: JSPS KAKENHI, Oita University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

During hemodialysis, proteins, such as albumin and globulin, are deposited on the dialysis membrane surface, causing fouling that affects solute removal and biocompatibility. This study aimed to measure the filtration coefficient as an index of dialysis membrane conditions in hemodialysis, pre-dilution online hemodiafiltration, and intermittent infusion hemodiafiltration modes using two different hemodiafiltration membranes ex vivo. The filtration coefficients of hemodiafiltration membranes in hemodialysis, pre-dilution online hemodiafiltration, and intermittent infusion hemodiafiltration modes were continuously measured for 123 min using 2 L bovine blood, which was adjusted with 32% hematocrit and 6.5 g/dL of total proteins. Polysulfone and cellulose triacetate were used as test membrane materials, and both membrane structures were asymmetric. The first fouling step was observed 20 s after filtration of both polysulfone and cellulose triacetate membranes in each mode. Thereafter, the filtration coefficient recovered in the pre-dilution online hemodiafiltration mode. However, it plateaued in the cellulose triacetate membrane and decreased in the polysulfone membrane. A flushing effect of the intermittent infusion hemodiafiltration mode was observed in both the cellulose triacetate and polysulfone membranes. The differences in fouling steps in each of the three modes—hemodialysis, pre-dilution online hemodiafiltration, and intermittent infusion hemodiafiltration—can be identified by continuously measuring filtration coefficient values.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Membranes, ArtificialHemodiafiltrationRenal DialysisBiofoulingSulfonesPolymersAnimalsCelluloseCattle

Stichwörter der Autor:innen

FoulingIntermittent infusion hemodiafiltrationOnline hemodiafiltration

Substanzen

Membranes, ArtificialSulfonespolysulfone P 1700PolymersCellulosecellulose triacetate

Autor:innen und Institutionen

  • Department of Advanced Medical Sciences, Faculty of Medicine, Oita University, 1-1 Idaigaoka, Hasama-Machi, Yufu, Oita, 879-5593, Japan. ytange@oita-u.ac.jp.
  • Graduate School of Health Sciences, Kyushu University of Medical Science, 1714-1 Yoshinomachi, Nobeoka, Miyazaki, 882-8508, Japan.
  • Department of Clinical Engineering, Tokatsu Clinic Hospital, 865-2 Hinokuchi, Matsudo, Chiba, 271-0067, Japan.

Förderung

  • JSPS KAKENHI
  • Oita University

Zitieren

APA

Tange, Y., Kawakami, M., & Takesawa, S. (2025). Fouling process of hemodiafiltration membranes by hemodialysis and hemodiafiltration therapy. Journal of Artificial Organs. https://doi.org/10.1007/s10047-025-01497-9

Vancouver

Tange Y, Kawakami M, Takesawa S. Fouling process of hemodiafiltration membranes by hemodialysis and hemodiafiltration therapy. Journal of Artificial Organs. 2025. doi:10.1007/s10047-025-01497-9

BibTeX
@article{Tange2025,
  author = {Tange, Yoshihiro and Kawakami, Masashi and Takesawa, Shingo},
  title = {Fouling process of hemodiafiltration membranes by hemodialysis and hemodiafiltration therapy},
  journal = {Journal of Artificial Organs},
  year = {2025},
  doi = {10.1007/s10047-025-01497-9}
}
Kostenlos starten →