A compact machine perfusion device for whole blood perfusion in isolated rat liver
Journal of Artificial Organs · 2025
DOI: 10.1007/s10047-024-01474-8 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Artificial Organs, 2025. Verfasst von Yuki Tamaki und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anatomy, Aichi Medical University, Nagakute, Aichi, 480-1195, Japan. tamaki.yuki.843@mail.aichi-med-u.ac.jp. Hauptthemen laut MEDLINE: Liver, Perfusion, Extracorporeal Circulation. Die Arbeit nennt 33 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science.
Abstract (Originalsprache)
We established a compact machine perfusion system for whole blood perfusion of rat liver by making use of oxygenation filters as an artificial lung. Livers removed from rats were divided into Krebs-Henseleit (control), 50% blood (hemoglobin: 7 g/dL), and whole blood (hemoglobin: 14 g/dL) groups, then perfused (total perfusate volume: 25 ml) with a small oxygenation filter at 37 °C for 120 min. Blood or perfusate was collected over time, and blood gas and blood cell were measured. In addition, bile volume and portal venous pressure measurements were taken. In all groups, the partial pressure of oxygen was controlled to approximately 400 mmHg. Flow rates were maintained at approximately about 20-30 ml/min according to liver size. Portal venous pressure was normal in the 50% blood and whole blood groups, while lower than the reference value in the Krebs-Henseleit group. Twice as much bile was produced in the 50% blood and whole blood groups relative with the Krebs-Henseleit group. We observed no differences in hemoglobin and red blood cell levels. Lactate levels were normal in the 50% blood and whole blood groups, but were elevated in the Krebs-Henseleit group. Our compact perfusion system using oxygenation filters was able to maintain rat liver function by perfusing a small amount of extracorporeal blood. This system is simple and stable, and may contribute to the future development of machine perfusion systems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anatomy, Aichi Medical University, Nagakute, Aichi, 480-1195, Japan. tamaki.yuki.843@mail.aichi-med-u.ac.jp.
- Department of Anatomy, Aichi Medical University, Nagakute, Aichi, 480-1195, Japan.
- Department of Clinical Engineering and Medical Technology, Niigata University of Health and Welfare, Niigata, Japan.
- Department of Anatomy, Aichi Medical University, Nagakute, Aichi, 480-1195, Japan. munekazunaito@gmail.com.
Förderung
- Japan Society for the Promotion of Science
Zitieren
APA
Tamaki, Y., Hatayama, N., Fujii, Y., & Naito, M. (2025). A compact machine perfusion device for whole blood perfusion in isolated rat liver. Journal of Artificial Organs. https://doi.org/10.1007/s10047-024-01474-8
Vancouver
Tamaki Y, Hatayama N, Fujii Y, Naito M. A compact machine perfusion device for whole blood perfusion in isolated rat liver. Journal of Artificial Organs. 2025. doi:10.1007/s10047-024-01474-8
BibTeX
@article{Tamaki2025,
author = {Tamaki, Yuki and Hatayama, Naoyuki and Fujii, Yutaka and Naito, Munekazu},
title = {A compact machine perfusion device for whole blood perfusion in isolated rat liver},
journal = {Journal of Artificial Organs},
year = {2025},
doi = {10.1007/s10047-024-01474-8}
}
EUVIMED