EUVIMEDEUVIMED entdecken
Systematische ÜbersichtMetaanalyse

Complications after biosynthetic long-term absorbable mesh implantation for ventral hernia repair in clean and contaminated environments: a systematic review and meta-analysis

Marie Wieser, Rudolf van den Berg, Benoit Romain

Hernia · 14.05.2026 · 30 (1)

DOI: 10.1007/s10029-026-03699-3 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Hernia, online erschienen am 14.05.2026. Verfasst von Marie Wieser und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Digestive Surgery, University of Strasbourg, Hautepierre, France. Hauptthemen laut MEDLINE: Surgical Mesh, Hernia, Ventral, Herniorrhaphy, Absorbable Implants. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 19 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Ventral hernia repair (VHR) remains a common yet complex surgical procedure, with substantial recurrence and complication rates. Long-term absorbable biosynthetic meshes have been introduced to provide temporary reinforcement while potentially reducing mesh‑related morbidity.

Objective

This meta-analysis evaluates the safety and effectiveness of long-term absorbable biosynthetic meshes in VHR by synthesizing both comparative and descriptive studies.

Methods

Databases were searched up to October 2025 for studies on VHR with long-term absorbable biosynthetic mesh. Descriptive studies were pooled using random-effects models to determine event rates. Comparative studies were analyzed using odds-ratios (ORs).

Results

Thirty-five descriptive single-arm studies and seventeen comparative studies were included. Descriptive hernia recurrence rate was 11.6% (95%CI 9.3–14.3%), surgical site infection (SSI) 11.8% (95%CI 9.2–15.0%), surgical site occurrence (SSO) 21.9% (95%CI 15.9–29.5%), seroma 9.7% (95%CI 7.2–12.9%), and SSO/SSI requiring surgical-intervention (SSOPI) 9.7% (95%CI 7.6–12.3%). Mesh infection and explantation rates were 0.3% (95%CI 0.0–1.0%) and 0.5% (95%CI 0.0–1.6%) both also in single-arm studies. A significantly lower hazard of recurrence 0.47 (95%CI 0.24–0.93), and a non-significantly lower risk of SSI, SSO, mesh explantation, and SSOPI compared to biologic meshes was found in comparative studies. Absorbable meshes showed a non-significant difference in recurrence rate versus permanent synthetic mesh (OR 0.93, 95%CI 0.57–1.52) but significantly lower odds of mesh explantation (OR 0.46, 95%CI 0.27–0.79).

Conclusions

Long-term absorbable biosynthetic meshes show low mesh infection and explantation rates in the available literature. Comparative analyses suggest lower recurrence versus biologic meshes and fewer explantations versus permanent synthetic meshes; however, these findings are based on heterogeneous, predominantly retrospective data with limited follow-up and should not be considered conclusive.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Surgical MeshHernia, VentralHerniorrhaphyAbsorbable ImplantsPostoperative ComplicationsHumansSurgical Wound InfectionRecurrence

Stichwörter der Autor:innen

Hernia recurrenceLong-term absorbable meshMeta-analysisSurgical site infectionSystematic reviewVentral hernia repair

Autor:innen und Institutionen

  • Department of Digestive Surgery, University of Strasbourg, Hautepierre, France.
  • Department of Surgery, Erasmus University Medical Centre, Rotterdam, the Netherlands.
  • Department of Digestive Surgery, University of Strasbourg, Hautepierre, France. benoit.romain@chru-strasbourg.fr.

Zitieren

APA

Wieser, M., van den Berg, R., & Romain, B. (2026). Complications after biosynthetic long-term absorbable mesh implantation for ventral hernia repair in clean and contaminated environments: a systematic review and meta-analysis. Hernia, 30(1). https://doi.org/10.1007/s10029-026-03699-3

Vancouver

Wieser M, van den Berg R, Romain B. Complications after biosynthetic long-term absorbable mesh implantation for ventral hernia repair in clean and contaminated environments: a systematic review and meta-analysis. Hernia. 2026;30(1). doi:10.1007/s10029-026-03699-3

BibTeX
@article{Wieser2026,
  author = {Wieser, Marie and van den Berg, Rudolf and Romain, Benoit},
  title = {Complications after biosynthetic long-term absorbable mesh implantation for ventral hernia repair in clean and contaminated environments: a systematic review and meta-analysis},
  journal = {Hernia},
  year = {2026},
  volume = {30},
  number = {1},
  doi = {10.1007/s10029-026-03699-3}
}
Kostenlos starten →