Vergleichsstudie in der Zeitschrift Hernia, online erschienen am 25.03.2026. Verfasst von Alessandro Verbo und 3 weiteren Autor:innen. Beteiligte Einrichtung: Catholic University of the Sacred Heart, Rome, Italy. alessandro.verbo@unicatt.it. Hauptthemen laut MEDLINE: Surgical Mesh, Laparoscopy, Herniorrhaphy, Hernia, Ventral. Die Arbeit nennt 11 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Università Cattolica del Sacro Cuore.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Laparoscopic IPOM repair is widely used for ventral hernia treatment. Hybrid biosynthetic meshes have been developed to improve tissue integration and functional recovery; however, comparative clinical evidence remains limited.

Methods

This was a single-center retrospective study conducted at a tertiary care institution between 2020 and 2025 including 95 consecutive patients undergoing laparoscopic IPOM repair. Forty-two patients received a hybrid biosynthetic mesh (SINECOR ® ) and 53 a conventional synthetic mesh. Demographic, clinical and surgical variables were analyzed, including defect size, mesh surface, operative time, complications, length of stay, functional and occupational recovery time, and quality of life (EuraHS-QoL). Hernia defects were classified as small (≤ 20 cm²), medium (21–100 cm²) and large (> 100 cm²). Mesh size was categorized as small (≤ 150 cm²), medium (151–400 cm²) and large (> 400 cm²). Delayed functional recovery was defined as occupational recovery > 30 days. Multivariable logistic regression was performed to identify independent predictors of delayed recovery; covariates included age > 65 years, BMI > 30 kg/m², defect size > 100 cm², mesh surface and mesh type (hybrid vs. conventional).

Results

Groups were comparable in BMI (25.8 vs. 25.8 kg/m², p = 0.92), whereas patients in the hybrid group tended to be slightly older (63 vs. 58.5 years, p = 0.08). Follow-up was significantly longer in the control group (46.9 vs. 20.4 months, p < 0.001). No large defects (> 100 cm²) were observed in the hybrid mesh group, while they accounted for about one third of cases in the control group. Despite this imbalance, mean mesh surface did not differ significantly between groups (200.7 vs. 255.9 cm², p = 0.11). Hybrid mesh was associated with significantly shorter operative time (52.3 vs. 79.7 min, p < 0.001), reduced length of stay (2.0 vs. 2.8 days, p = 0.001), faster functional recovery (return to physical activity 10.5 vs. 13.5 days, p = 0.004; return to work 17.0 vs. 25.1 days, p < 0.001), and higher EuraHS-QoL scores (90.2 vs. 80.1, p < 0.001). Overall postoperative complication rates and seroma occurrence were comparable between groups. Recurrence was less frequent in the hybrid group (2.4% vs. 20.8%, p = 0.01) in the context of markedly shorter follow-up. On multivariable analysis, use of hybrid biosynthetic mesh remained the only independent predictor of faster functional recovery (OR 0.09; 95% CI 0.01–0.77; p = 0.028), with acceptable model calibration (Hosmer–Lemeshow p = 0.51; AUC = 0.73).

Conclusions

In laparoscopic IPOM repair, hybrid biosynthetic mesh was associated with improved functional recovery and quality of life for small-to-medium defects, with a safety profile comparable to conventional meshes. Recurrence appeared lower with hybrid mesh, although interpretation is limited by shorter follow-up. Larger prospective studies are warranted to confirm these findings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Surgical MeshLaparoscopyHerniorrhaphyHernia, VentralHumansRetrospective StudiesFemaleMiddle AgedRecovery of FunctionMaleQuality of LifeAgedLength of StayPostoperative ComplicationsTreatment OutcomeOperative Time

Stichwörter der Autor:innen

Hernia repairHybrid biosynthetic meshIPOMQuality of lifeVentral hernia

Autor:innen und Institutionen

  • Catholic University of the Sacred Heart, Rome, Italy. alessandro.verbo@unicatt.it.
  • Mater Olbia Hospital, Olbia, Italy.
  • Sapienza University of Rome, Rome, Italy.

Förderung

  • Università Cattolica del Sacro Cuore

Zitieren

APA

Verbo, A., Bez, M. A., Di Giorgio, D., & Verbo, I. (2026). Clinical and functional outcomes after laparoscopic IPOM repair: A comparison between hybrid biosynthetic and conventional meshes. Hernia, 30(1). https://doi.org/10.1007/s10029-026-03604-y

Vancouver

Verbo A, Bez MA, Di Giorgio D, Verbo I. Clinical and functional outcomes after laparoscopic IPOM repair: A comparison between hybrid biosynthetic and conventional meshes. Hernia. 2026;30(1). doi:10.1007/s10029-026-03604-y

BibTeX
@article{Verbo2026,
  author = {Verbo, Alessandro and Bez, Mattia Angelo and Di Giorgio, Danilo and Verbo, Iacopo},
  title = {Clinical and functional outcomes after laparoscopic IPOM repair: A comparison between hybrid biosynthetic and conventional meshes},
  journal = {Hernia},
  year = {2026},
  volume = {30},
  number = {1},
  doi = {10.1007/s10029-026-03604-y}
}
Kostenlos starten →