EUVIMEDEUVIMED entdecken
Multizentrische StudieOpen Access · CC BY 4.0

Evaluation of radiologists’ accuracy and interrater reliability when interpreting CT scans after ventral hernia repair

Fahim Kanani iD, Rina Neeman, Narmin Zoabi, Elad Karin, Bar Cohen, Eran Nizri, Adam Abu Abeid, Yonatan Lessing, Guy Lahat, Michael J Rosen, Nir Messer

Hernia · 2025

DOI: 10.1007/s10029-025-03504-7 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Hernia, 2025. Verfasst von Fahim Kanani und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Tel Aviv Medical Center, Tel Aviv, Israel. kanani.fahim@gmail.com. Hauptthemen laut MEDLINE: Hernia, Ventral, Tomography, X-Ray Computed, Herniorrhaphy, Radiologists. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Tel Aviv University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Accurate interpretation of computed tomography (CT) prior to ventral hernia repair (VHR) is critical for operative planning, particularly in recurrent cases where prior mesh type and placement influence surgical approach. While radiologists possess specialized expertise in imaging interpretation, their performance in identifying post-VHR mesh characteristics remains unstudied. This study assesses the diagnostic performance of radiologists in identifying mesh plane and type on CT following VHR.

Methods

Forty body radiologists from 16 centers evaluated 18 de-identified CT scans, including 12 post-VHR cases and 6 controls. After receiving standardized training on mesh characteristics and surgical planes, radiologists were tasked with identifying both the VHR mesh plane and the mesh type. The study assessed correct identification rates, interrater reliability, and repeatability.

Results

Radiologists demonstrated overall accuracy rates of 39.2% for mesh plane identification and 43.5% for mesh type identification. Accuracy was highest for intraperitoneal approaches (53.8%) and heavy-weight mesh (52.5%), with significantly lower accuracy (16.9–22.5%) for other surgical planes and mesh types (30.6%). Interrater reliability was poor (Gwet’s AC1 = 0.127), with significant between-radiologist variability. Self-reported confidence levels correlated positively with accuracy rates, with high-confidence radiologists showing significantly better performance (OR 4.55, p < 0.001). Years of clinical experience did not predict diagnostic accuracy.

Conclusions

Radiologists demonstrated limited ability to accurately interpret post-VHR CT scans, even after targeted instruction. These diagnostic challenges mirror findings among abdominal wall reconstruction surgeons, suggesting inherent limitations in CT-based assessment rather than discipline-specific deficits. Multidisciplinary collaboration, standardized operative documentation, and dedicated abdominal wall imaging protocol and training are essential to improve diagnostic accuracy and optimize surgical planning.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hernia, VentralTomography, X-Ray ComputedHerniorrhaphyRadiologistsClinical CompetenceHumansReproducibility of ResultsSurgical MeshObserver VariationFemaleMale

Stichwörter der Autor:innen

AccuracyComputed tomography (CT)InterpretationInterrater reliabilityMesh planeMesh typeReoperationVentral hernia repair

Autor:innen und Institutionen

  • Department of Surgery, Tel Aviv Medical Center, Tel Aviv, Israel. kanani.fahim@gmail.com.
  • Department of Surgery, Wolfson Medical Center, Tel Aviv, Israel. kanani.fahim@gmail.com.
  • Department of Radiology, Tel Aviv Medical Center, Tel Aviv, Israel.
  • Department of Gastroenterology, Sheba Medical Center, Ramat Gan, Israel.
  • Department of Surgery, Tel Aviv Medical Center, Tel Aviv, Israel.
  • Division of GI Surgery, Northwestern University, Chicago, IL, US.

ORCID-Profile: Fahim Kanani

Förderung

  • Tel Aviv University

Zitieren

APA

Kanani, F., Neeman, R., Zoabi, N., Karin, E., Cohen, B., Nizri, E., Abeid, A. A., Lessing, Y., Lahat, G., Rosen, M. J., & Messer, N. (2025). Evaluation of radiologists’ accuracy and interrater reliability when interpreting CT scans after ventral hernia repair. Hernia. https://doi.org/10.1007/s10029-025-03504-7

Vancouver

Kanani F, Neeman R, Zoabi N, Karin E, Cohen B, Nizri E, et al. Evaluation of radiologists’ accuracy and interrater reliability when interpreting CT scans after ventral hernia repair. Hernia. 2025. doi:10.1007/s10029-025-03504-7

BibTeX
@article{Kanani2025,
  author = {Kanani, Fahim and Neeman, Rina and Zoabi, Narmin and Karin, Elad and Cohen, Bar and Nizri, Eran and Abeid, Adam Abu and Lessing, Yonatan and Lahat, Guy and Rosen, Michael J and Messer, Nir},
  title = {Evaluation of radiologists’ accuracy and interrater reliability when interpreting CT scans after ventral hernia repair},
  journal = {Hernia},
  year = {2025},
  doi = {10.1007/s10029-025-03504-7}
}
Kostenlos starten →