Prevention of incisional hernia with biosynthetic mesh at the site of temporary ileostomy closure (PRINCESS Study): Preliminary Results
Hernia · 2025
DOI: 10.1007/s10029-025-03462-0 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Hernia, 2025. Verfasst von Roberto Peltrini und 34 weiteren Autor:innen. Beteiligte Einrichtung: Department of Public Health, University of Naples Federico II, Via Pansini 5, Naples, 80131, Italy. roberto.peltrini@gmail.com. Hauptthemen laut MEDLINE: Surgical Mesh, Ileostomy, Incisional Hernia. Die Arbeit nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Università degli Studi di Napoli Federico II.
Abstract (Originalsprache)
Purpose
Incisional hernia after ileostomy closure is a complication that adversely affects patient outcomes, quality of life (QoL), healthcare resources, and related costs. Prophylactic mesh reinforcement, both biological and synthetic, has been shown to be safe and effective in preventing stoma site incisional hernia (SSIH). This study aimed to evaluate the use of a slowly absorbable biosynthetic mesh at the site of temporary ileostomy closure to prevent SSIH.
Methods
This prospective, single-arm observational study was conducted across 14 Italian hospitals. Patients undergoing ileostomy reversal with retromuscular placement of a poly-4-hydroxybutyrate (Phasix™) mesh were enrolled. Endpoints included the incidence of radiologically and clinically detected SSIH at 1-year, postoperative morbidity, wound complications, and QoL assessed using the EuroQoL 5D-5 L and Carolinas Comfort Scale (CCS) questionnaires.
Results
A total of 115 patients completed at least 1 year of follow-up and were included in the analysis. Seromas was the most frequent complication (8.6%). Superficial and deep SSIs occurred in 6% and 1.7% of patients, respectively. Three complications required intervention (2.6%), including one mesh removal. The 1-year SSIH rate was 1.7%, with a median follow-up of 477 d (range: 263–880). Considering the 55 patients (47.8%) who completed 2-year follow-up, the cumulative SSIH rate was 4.3%. EuroQoL 5D-5 L and CCS scores demonstrated progressive improvement in QoL and symptom reduction over time ( p < 0.0001).
Conclusion
These preliminary findings suggest that prophylactic placement of a slowly absorbable biosynthetic mesh (Phasix™) is safe and effective for SSIH prevention following ileostomy closure, without negatively impacting the patient’s QoL. The use of biosynthetic meshes may be considered a valid alternative to biological or synthetic meshes in this setting.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Public Health, University of Naples Federico II, Via Pansini 5, Naples, 80131, Italy. roberto.peltrini@gmail.com.
- Centre for Research on Health and Social Care Management (CERGAS), School of Management, SDA Bocconi, Bocconi University, Via Sarfatti 10, Milan, 20136, Italy.
- UOC Chirurgia Generale, "D. Camberlingo" Hospital, Francavilla Fontana, Italy.
- UOC Chirurgia Colorettale, Fondazione Policlinico Universitario Campus Bio-Medico Di Roma, Via Alvaro del Portillo, Rome, 21 - 00128, Italy.
- Department of General Surgery, General Surgery Unit, S. Eugenio Hospital, Rome, Italy.
- General Surgery and Trauma Team, GOM Niguarda, Piazza Ospedale Maggiore 3, Milan, 20162, Italy.
ORCID-Profile: Roberto Peltrini
Förderung
- Università degli Studi di Napoli Federico II
Zitieren
APA
Peltrini, R., Rognoni, C., Bellanova, G., Caricato, M., Carlini, M., Cimbanassi, S., Corcione, F., Cozzani, F., Cuccurullo, D., Faillace, G., Neri, S., Patriti, A., Santarelli, M., Trapani, V., Capolupo, G. T., Carbone, G., Cianflocca, D., Cioffi, S., Di Nuzzo, M. M., …, & Bracale, U. (2025). Prevention of incisional hernia with biosynthetic mesh at the site of temporary ileostomy closure (PRINCESS Study): Preliminary Results. Hernia. https://doi.org/10.1007/s10029-025-03462-0
Vancouver
Peltrini R, Rognoni C, Bellanova G, Caricato M, Carlini M, Cimbanassi S, et al. Prevention of incisional hernia with biosynthetic mesh at the site of temporary ileostomy closure (PRINCESS Study): Preliminary Results. Hernia. 2025. doi:10.1007/s10029-025-03462-0
BibTeX
@article{Peltrini2025,
author = {Peltrini, Roberto and Rognoni, Carla and Bellanova, Giovanni and Caricato, Marco and Carlini, Massimo and Cimbanassi, Stefania and Corcione, Francesco and Cozzani, Federico and Cuccurullo, Diego and Faillace, Giuseppe and Neri, Silvia and Patriti, Alberto and Santarelli, Mauro and Trapani, Vincenzo and Capolupo, Gabriella Teresa and Carbone, Gabriele and Cianflocca, Desiree and Cioffi, Stefano and Di Nuzzo, Maria Michela and Ferrara, Davide and Greco, Paola Antonella and Iacone, Biancamaria and Pecchini, Francesca and Rossini, Matteo and Sacco, Michele and Sala, Stefano and Spoletini, Domenico and Tramontano, Salvatore and Tarricone, Rosanna and Campanelli, Giampiero and Cavallaro, Giuseppe and Piccoli, Micaela and Soliani, Giorgio and Stabilini, Cesare and Bracale, Umberto},