EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Is mesh pore size in polypropylene meshes associated with the outcome in Lichtenstein inguinal hernia repair: a registry-based analysis of 22,141 patients

H C Albrecht iD, M Trawa, F Köckerling, D Adolf, M Hukauf, H Riediger, S Gretschel iD

Hernia · 2024

DOI: 10.1007/s10029-024-03029-5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Hernia, 2024. Verfasst von H C Albrecht und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of General, Visceral, Thoracic and Vascular Surgery, Faculty of Health Science Brandenburg, Brandenburg Medical School, University Hospita…. Hauptthemen laut MEDLINE: Surgical Mesh, Polypropylenes, Hernia, Inguinal, Registries. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medizinische Hochschule Brandenburg CAMPUS GmbH.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Experimental data show that large-pored meshes reduce foreign body reaction, inflammation and scar bridging and thus improve mesh integration. However, clinical data on the effect of mesh porosity on the outcome of hernioplasty are limited. This study investigated the relation of pore size in polypropylene meshes to the outcome of Lichtenstein inguinal hernioplasty using data from the Herniamed registry.

Methods

This analysis of data from the Herniamed registry evaluated perioperative and 1-year follow-up outcomes in patients undergoing elective, primary, unilateral Lichtenstein inguinal hernia repair using polypropylene meshes. Patients operated with a non-polypropylene mesh or a polypropylene mesh with absorbable components were excluded. Polypropylene meshes with a pore size of 1.0 × 1.0 mm or less were defined as small-pored meshes, while a pore size of more than 1.0 × 1.0 mm was considered large-pored. Unadjusted analyses and multivariable analyses were performed to investigate the relation of pore size of polypropylene meshes, patient and surgical characteristics to the outcome parameters.

Results

Data from 22,141 patients were analyzed, of which 6853 (31%) were operated on with a small-pore polypropylene mesh and 15,288 (69%) with a large-pore polypropylene mesh. No association of mesh pore size with intraoperative, general or postoperative complications, recurrence rate or pain requiring treatment was found at 1-year follow-up. A lower risk of complication-related reoperation tended to be associated with small-pore size ( p = 0.086). Furthermore, small-pore mesh repair was associated with a lower risk of pain at rest and pain on exertion at 1-year follow-up.

Conclusion

The present study could not demonstrate an advantage of large-pore polypropylene meshes for the outcome of Lichtenstein inguinal hernioplasty.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Surgical MeshPolypropylenesHernia, InguinalRegistriesHerniorrhaphyHumansMaleMiddle AgedFemalePorosityAgedAdultTreatment OutcomePostoperative PainRecurrence

Stichwörter der Autor:innen

Chronic painHernia recurrenceInguinal herniaLichtenstein hernioplastyMesh pore sizeOutcome hernia repair

Substanzen

Polypropylenes

Autor:innen und Institutionen

  • Department of General, Visceral, Thoracic and Vascular Surgery, Faculty of Health Science Brandenburg, Brandenburg Medical School, University Hospital Ruppin-Brandenburg, Fehrbelliner Str. 38, 16816, Neuruppin, Germany.
  • Department of Surgery, Hernia Center, Academic Teaching Hospital of Charité Medical School, Vivantes Humboldt-Hospital Berlin, Berlin, Germany.
  • StatConsult GmbH, Magdeburg, Germany.
  • Department of General, Visceral, Thoracic and Vascular Surgery, Faculty of Health Science Brandenburg, Brandenburg Medical School, University Hospital Ruppin-Brandenburg, Fehrbelliner Str. 38, 16816, Neuruppin, Germany.…

ORCID-Profile: H C Albrecht, S Gretschel

Förderung

  • Medizinische Hochschule Brandenburg CAMPUS GmbH

Zitieren

APA

Albrecht, H. C., Trawa, M., Köckerling, F., Adolf, D., Hukauf, M., Riediger, H., & Gretschel, S. (2024). Is mesh pore size in polypropylene meshes associated with the outcome in Lichtenstein inguinal hernia repair: a registry-based analysis of 22,141 patients. Hernia. https://doi.org/10.1007/s10029-024-03029-5

Vancouver

Albrecht HC, Trawa M, Köckerling F, Adolf D, Hukauf M, Riediger H, et al. Is mesh pore size in polypropylene meshes associated with the outcome in Lichtenstein inguinal hernia repair: a registry-based analysis of 22,141 patients. Hernia. 2024. doi:10.1007/s10029-024-03029-5

BibTeX
@article{Albrecht2024,
  author = {Albrecht, H C and Trawa, M and Köckerling, F and Adolf, D and Hukauf, M and Riediger, H and Gretschel, S},
  title = {Is mesh pore size in polypropylene meshes associated with the outcome in Lichtenstein inguinal hernia repair: a registry-based analysis of 22,141 patients},
  journal = {Hernia},
  year = {2024},
  doi = {10.1007/s10029-024-03029-5}
}
Kostenlos starten →