Fachartikel in der Zeitschrift Clinical Oral Investigations, online erschienen am 02.10.2026. Verfasst von Andrea Spinelli und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical and Neuromotor Sciences, Endodontic Clinical Section, Dental School, University of Bologna, Bologna, Italy. Hauptthemen laut MEDLINE: Tooth Apex. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To radiographically evaluate short-term changes in NeoSealer Flo extruded beyond enlarged apical preparations under different moisture and apical-support conditions. Materials and methods Thirty-two extracted single-rooted human teeth were randomly allocated to four experimental conditions ( n = 8 per group). Teeth were prepared with reciprocating NiTi instruments to size 50/0.05 and filled with a matched gutta-percha cone and a premixed bioceramic sealer. The conditions combined the presence or absence of sponge support around the apex with dry or phosphate-buffered saline PBS-moistened canals. Standardized radiographs were acquired immediately after filling (T0), at 7 days (T1), and at 28 days (T2). Intracanal radiopaque area (Area of the canal, AOC) and apically extruded radiopaque area (Area of Extrusion, AE) were traced within a calibrated 6 × 10-mm region of interest. Separate random-intercept linear mixed models included group, time, and their interaction; pairwise comparisons used Sidak adjustment.

Results

Mean AOC changed by no more than 0.56 mm² within groups. The group-by-time interaction was not significant for AOC (Wald χ²(6) = 5.31, p = 0.505) but was significant for AE (Wald χ²(6) = 21.72, p = 0.001). From T0 to T2, mean AE changed by + 3.38 mm² (Group 1; dry/sponge), + 0.25 mm² (Group 2; moist/sponge), + 1.50 mm² (Group 3; dry/no sponge), and + 0.41 mm² (Group 4; moist/no sponge).

Conclusions

Intracanal radiopaque area remained relatively stable over 28 days, whereas the extruded radiopaque area differed among experimental conditions. The largest mean increase occurred in the dry, sponge-supported group. Clinical relevance Local moisture and periapical status may influence the radiopaque area of extruded NeoSealer Flo. However, the radiographic changes do not directly demonstrate material expansion, dissolution, resorption, or biological integration. Apical extrusion should be minimized in clinical practice.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tooth ApexHumansRoot Canal Filling MaterialsIn Vitro TechniquesRoot Canal PreparationRadiography

Stichwörter der Autor:innen

Apical extrusionBioceramic sealerCalcium silicateEndodonticsPeriapical radiographyRoot canal obturation

Substanzen

Root Canal Filling Materials

Autor:innen und Institutionen

  • Department of Biomedical and Neuromotor Sciences, Endodontic Clinical Section, Dental School, University of Bologna, Bologna, Italy.
  • Department of Biomedical and Neuromotor Sciences, Laboratory of Green Biomaterials and Oral Pathology, Dental School, University of Bologna, Bologna, Italy.
  • Department of Biomedical and Neuromotor Sciences, Endodontic Clinical Section, Dental School, University of Bologna, Bologna, Italy. fausto.zamparini2@unibo.it.
  • Department of Biomedical and Neuromotor Sciences, Laboratory of Green Biomaterials and Oral Pathology, Dental School, University of Bologna, Bologna, Italy. fausto.zamparini2@unibo.it.

Zitieren

APA

Spinelli, A., Pergola, V., Prati, C., Gandolfi, M. G., & Zamparini, F. (2026). Short-term radiographic changes of extruded NeoSealer Flo in a simulated enlarged-apex model: influence of moisture and periapical support. Clinical Oral Investigations, 30(10). https://doi.org/10.1007/s00784-026-07175-1

Vancouver

Spinelli A, Pergola V, Prati C, Gandolfi MG, Zamparini F. Short-term radiographic changes of extruded NeoSealer Flo in a simulated enlarged-apex model: influence of moisture and periapical support. Clinical Oral Investigations. 2026;30(10). doi:10.1007/s00784-026-07175-1

BibTeX
@article{Spinelli2026,
  author = {Spinelli, Andrea and Pergola, Valentina and Prati, Carlo and Gandolfi, Maria Giovanna and Zamparini, Fausto},
  title = {Short-term radiographic changes of extruded NeoSealer Flo in a simulated enlarged-apex model: influence of moisture and periapical support},
  journal = {Clinical Oral Investigations},
  year = {2026},
  volume = {30},
  number = {10},
  doi = {10.1007/s00784-026-07175-1}
}
Kostenlos starten →