Evaluation of the marginal and internal fit of endocrown restorations fabricated by the CAD/CAM system using additive manufacturing technique
Clinical Oral Investigations · 29.04.2026 · 30 (5)
DOI: 10.1007/s00784-026-06891-y ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Oral Investigations, online erschienen am 29.04.2026. Verfasst von Eric Arnold Dos Santos Brito und 8 weiteren Autor:innen. Beteiligte Einrichtung: Departamento de Materiais Dentários e Prótese, Faculdade de Odontologia de Ribeirão Preto, Universidade de São Paulo, Avenida do Café, sn. Bairro Mon…. Hauptthemen laut MEDLINE: Computer-Aided Design, Dental Marginal Adaptation, Dental Prosthesis Design, Crowns. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universidade De São Paulo.
Abstract (Originalsprache)
Objective
This study aimed to compare the marginal and internal fit of endocrowns with cavity depths of 3 mm and 5 mm, using two printable resins fabricated by additive manufacturing within a digital workflow. Materials and methods Thirty-two human mandibular molars were prepared for endocrowns with cavity depths of 3–5 mm and allocated into four groups ( n = 8). Two printable resins (Biocrown Diamond and Voxel Print) were evaluated at both preparation depths. The restorations were designed using CAD software and manufactured by DLP-based additive manufacturing. Marginal and internal fit were assessed using micro-computed tomography (micro-CT) from standardized sagittal and coronal sections at predefined anatomical regions. Data were analyzed using two-way repeated-measures ANOVA followed by Tukey’s test (α = 0.05).
Results
Material and preparation depth influenced the marginal and internal fit of endocrown restorations, with a significant interaction with the anatomical region. The highest discrepancies were observed in the axio-occlusal angle, particularly for the 5-mm preparation groups. Significant differences between materials occurred at the axio-occlusal angle for 3-mm preparations and in the marginal gap for 5-mm preparations. No significant differences were detected in the pulpal regions.
Conclusion
Endocrowns showed clinically acceptable marginal adaptation at both preparation depths. However, internal adaptation was region-dependent, with greater discrepancies in the axio-occlusal region. Both resins demonstrated acceptable behavior, although localized differences were observed according to preparation depth and anatomical region. Clinical significance Preparation depth and printable resin type may influence the internal adaptation of additively manufactured endocrowns and should be considered during treatment planning.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Departamento de Materiais Dentários e Prótese, Faculdade de Odontologia de Ribeirão Preto, Universidade de São Paulo, Avenida do Café, sn. Bairro Monte Alegre. CEP 14040904, Ribeirão Preto, São Paulo, Brazil.
- Department of Restorative Dentistry, Ribeirão Preto School of Dentistry, University of São Paulo (USP), Ribeirão Preto, São Paulo, Brazil.
- Departamento de Materiais Dentários e Prótese, Faculdade de Odontologia de Ribeirão Preto, Universidade de São Paulo, Avenida do Café, sn. Bairro Monte Alegre. CEP 14040904, Ribeirão Preto, São Paulo, Brazil. catirapell…
Förderung
- Universidade De São Paulo
Zitieren
APA
Santos Brito, E. A. D., Souza, M. M., Borges, M. S. N., Ramos, M. J. L., Godoi-Lopes, J., Cardoso, L., Sousa-Neto, M. D., Chaves, J. F. M., & Tirapelli, C. (2026). Evaluation of the marginal and internal fit of endocrown restorations fabricated by the CAD/CAM system using additive manufacturing technique. Clinical Oral Investigations, 30(5). https://doi.org/10.1007/s00784-026-06891-y
Vancouver
Santos Brito EAD, Souza MM, Borges MSN, Ramos MJL, Godoi-Lopes J, Cardoso L, et al. Evaluation of the marginal and internal fit of endocrown restorations fabricated by the CAD/CAM system using additive manufacturing technique. Clinical Oral Investigations. 2026;30(5). doi:10.1007/s00784-026-06891-y
BibTeX
@article{SantosBrito2026,
author = {Santos Brito, Eric Arnold Dos and Souza, Murilo Montanari and Borges, Marianna Soares Nogueira and Ramos, Maria Julia Lopes and Godoi-Lopes, Julia and Cardoso, Leandro and Sousa-Neto, Manoel Damião and Chaves, Jardel Francisco Mazzi and Tirapelli, Camila},
title = {Evaluation of the marginal and internal fit of endocrown restorations fabricated by the CAD/CAM system using additive manufacturing technique},
journal = {Clinical Oral Investigations},
year = {2026},
volume = {30},
number = {5},
doi = {10.1007/s00784-026-06891-y}
}