EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Fracture resistance of molars receiving nanoceramic-resin CAD/CAM onlays after cervical marginal elevation with different injectable restorative materials: effect of six-month water storage

Basema Nader Roshdy, Radwa Ibrahim Eltoukhy, Ashraf Ibrahim Ali, Salah Hasab Mahmoud

Clinical Oral Investigations · 2025

DOI: 10.1007/s00784-025-06509-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Oral Investigations, 2025. Verfasst von Basema Nader Roshdy und 3 weiteren Autor:innen. Beteiligte Einrichtung: Conservative Dentistry Department, Faculty of Dentistry, Horus University, New Damietta, Egypt. Hauptthemen laut MEDLINE: Molar, Computer-Aided Design, Composite Resins, Inlays. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Mansoura University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To assess the influence of six-month water storage on the fracture resistance of molars receiving mesio-occluso-distal (MOD) nanoceramic CAD/CAM onlay restorations after cervical marginal elevation (CME) with different injectable restorative materials. Materials and methods Two hundred ten sound mandibular molars received standardized MOD onlay preparations with cervical margins extending 2 mm apical to the cementoenamel junction (CEJ). Molars were randomly assigned into five groups ( n = 42) according to the restorative materials used for CME: No-CME Group, control; CME-HVGI Group, highly viscous glass ionomer; CME-ICR Group, injectable composite resin; CME-RMGI Group, resin-modified glass ionomer; CME-BAIR Group, bioactive ionic resin. Immediate dentin sealing was performed on each molar before receiving nanoceramic-resin CAD/CAM onlay restoration. Each group was subdivided into two subgroups ( n = 21) based on whether they underwent six months of water storage. All specimens were subjected to clinical simulation via thermo-mechanical loading, fracture resistance testing, and failure mode analysis.

Results

No statistically significant difference in fracture resistance was observed when comparing the tested CME groups to the control group after six months of water storage. Regarding failure mode, irreparable failure was significantly dominant, with no significant difference among all groups.

Conclusions

Six-month water storage had no adverse effect on the fracture resistance of teeth receiving nanoceramic onlay restorations, regardless of the type of cervical margin elevating material used. Clinical relevance The smoothly handled injectable restorative materials used for CME of molars with nanoceramic-resin CAD/CAM onlay restorations could endure humid conditions, exhibiting acceptable performance under compressive loading.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MolarComputer-Aided DesignComposite ResinsInlaysTooth FracturesDental MaterialsDental Restoration, PermanentHumansWaterMaterials TestingDental Stress AnalysisIn Vitro TechniquesCeramicsGlass Ionomer Cements

Stichwörter der Autor:innen

Bioactive materialsCervical margin elevationFracture resistanceInjectable materialsOnlay restorationsWater storage

Substanzen

Composite ResinsWaterDental MaterialsGlass Ionomer Cements

Autor:innen und Institutionen

  • Conservative Dentistry Department, Faculty of Dentistry, Horus University, New Damietta, Egypt.
  • Conservative Dentistry Department, Faculty of Dentistry, Mansoura University, 77 Al Gomhoria St, Mansoura, 35516, Egypt.
  • Conservative Dentistry Department, Faculty of Dentistry, Mansoura University, 77 Al Gomhoria St, Mansoura, 35516, Egypt. salahmahmoud2010@mans.edu.eg.

Förderung

  • Mansoura University

Zitieren

APA

Roshdy, B. N., Eltoukhy, R. I., Ali, A. I., & Mahmoud, S. H. (2025). Fracture resistance of molars receiving nanoceramic-resin CAD/CAM onlays after cervical marginal elevation with different injectable restorative materials: effect of six-month water storage. Clinical Oral Investigations. https://doi.org/10.1007/s00784-025-06509-9

Vancouver

Roshdy BN, Eltoukhy RI, Ali AI, Mahmoud SH. Fracture resistance of molars receiving nanoceramic-resin CAD/CAM onlays after cervical marginal elevation with different injectable restorative materials: effect of six-month water storage. Clinical Oral Investigations. 2025. doi:10.1007/s00784-025-06509-9

BibTeX
@article{Roshdy2025,
  author = {Roshdy, Basema Nader and Eltoukhy, Radwa Ibrahim and Ali, Ashraf Ibrahim and Mahmoud, Salah Hasab},
  title = {Fracture resistance of molars receiving nanoceramic-resin CAD/CAM onlays after cervical marginal elevation with different injectable restorative materials: effect of six-month water storage},
  journal = {Clinical Oral Investigations},
  year = {2025},
  doi = {10.1007/s00784-025-06509-9}
}
Kostenlos starten →