Fachartikel in der Zeitschrift Clinical Oral Investigations, 2025. Verfasst von Arslandaş Dinçtürk B und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Restorative Dentistry, Faculty of Dentistry, University of Gazi, Ankara, Turkey. Hauptthemen laut MEDLINE: Computer-Aided Design, Dental Restoration Failure, Crowns, Dental Prosthesis Design. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Turku.
Abstract (Originalsprache)
Objectives
The aim of this study was to evaluate the fracture resistance of endocrowns made of experimental short fiber-reinforced CAD/CAM block (SFRC CAD) in comparison with different commercial CAD/CAM materials. Materials and methods In this study, 60 sound mandibular molar teeth with similar occlusal sizes (± 1 mm) were used. Standard preparations simulating an endocrown cavity were prepared and the teeth were divided into four groups randomly. After the digital photoimpression of the prepared cavities using a dental intraoral scanner (CEREC), the restorations were designed (4 mm high) and milled using IPS e.max, Cerasmart 270, Katana Avencia and SFRC CAD blocks ( n = 15/per group). Restorations were cemented with self-adhesive dual-cure resin cement (G-Cem One). The specimens were immersed in a 37 °C water bath within the chewing simulator. Following cyclic fatigue aging for 1.000.000 cycles (F max =150 N), a quasi-static load was applied using a universal testing machine at a speed of 1 mm/min. Fractography analysis was conducted using optical microscopy.
Results
According to the data obtained, there are statistically significant differences in fracture resistance values between different CAD/CAM materials ( p < 0.05). The highest values were observed in the experimental SFRC CAD group (3025 N), while the lowest values were observed in the IPS e.max group (2295 N).
Conclusions
The type of CAD/CAM restorative material influences the fracture resistance of endocrowns. SFRC CAD blocks could potentially serve as an alternative material for endocrown restorations in the future. Clinical relevance Endocrowns fabricated from SFRC CAD blocks have demonstrated promising fracture behavior, suggesting their suitability for clinical testing.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Restorative Dentistry, Faculty of Dentistry, University of Gazi, Ankara, Turkey.
- Department of Biomaterials Science and Turku Clinical Biomaterial Center - TCBC Institute of Dentistry, University of Turku, Turku, Finland. sufgar@utu.fi.
- Department of Biomaterials Science and Turku Clinical Biomaterial Center - TCBC Institute of Dentistry, University of Turku, Turku, Finland.
- Wellbeing Services County of South-West Finland, Turku, Finland.
Förderung
- University of Turku
Zitieren
APA
Dinçtürk B, A., Garoushi, S., Alp C, K., Pk, V., Mb, Ü., & Lassila, L. (2025). Fracture resistance of endocrowns made from different CAD/CAM materials after prolonged fatigue aging. Clinical Oral Investigations. https://doi.org/10.1007/s00784-025-06241-4
Vancouver
Dinçtürk B A, Garoushi S, Alp C K, Pk V, Mb Ü, Lassila L. Fracture resistance of endocrowns made from different CAD/CAM materials after prolonged fatigue aging. Clinical Oral Investigations. 2025. doi:10.1007/s00784-025-06241-4
BibTeX
@article{DintrkB2025,
author = {Dinçtürk B, Arslandaş and Garoushi, Sufyan and Alp C, Kedici and Pk, Vallittu and Mb, Üçtaşlı and Lassila, L},
title = {Fracture resistance of endocrowns made from different CAD/CAM materials after prolonged fatigue aging},
journal = {Clinical Oral Investigations},
year = {2025},
doi = {10.1007/s00784-025-06241-4}
}
EUVIMED