Physicochemical properties and biological interaction of calcium silicate-based sealers - in vivo model
Clinical Oral Investigations · 2025
DOI: 10.1007/s00784-025-06150-6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Oral Investigations, 2025. Verfasst von Ana Cristina Padilha Janini und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Restorative Dentistry - Endodontics, Faculdade de Odontologia de Piracicaba, Universidade Estadual de Campinas, Piracicaba, SP, Brazil. Hauptthemen laut MEDLINE: Root Canal Filling Materials, Silicates, Calcium Compounds. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 61 Literaturangaben. Gefördert von: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Fundação de Amparo à Pesquisa do Estado de São Paulo.
Abstract (Originalsprache)
OBJECTIVES: To investigate volumetric changes, in vivo biocompatibility, and systemic migration from eight commercial endodontic sealer materials in paste/paste, powder/liquid, and pre-mixed forms. MATERIALS AND METHODS: The sealers AH Plus Bioceramic, AH Plus Jet, BioRoot RCS, MTApex, Bio-C Sealer, Bio-C Sealer Ion+, EndoSequence BC Sealer and NeoSEALER Flo were studied. After characterisation by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), Raman spectroscopy and X-ray diffractometry (XRD), tubes were implanted in Wistar rats' alveolar bone and subcutaneous tissues. Micro-CT evaluated volumetric changes pre/post 30 days of implantation. Histological and immunohistochemistry analyses assessed biocompatibility. Kidney samples underwent spectrometry (ICP-MS) for tantalum, tungsten and zirconium. Statistical analysis determined normality and significance (udp < 0.05). RESULTS: Characterisation revealed calcium, silicon, and radiopacifiers in the materials. Volumetric changes showed greater alteration in subcutaneous tissues than alveolar bone; BioRoot RCS and MTApex (powder/liquid) were most stable. Histological analysis indicated intense inflammation for AH Plus Jet, moderate for others; IL-10 was marked positively for all materials. AH Plus Jet had an 18-fold higher tungsten and a 37-fold higher zirconium mass fraction in kidneys versus controls, while tantalum showed lower accumulation patterns. CONCLUSION: Root canal filling materials' responses varied by implantation site and form, demonstrating acceptable biocompatibility. Tantalum and zirconium oxide radiopacifiers appear systemically safe; tungsten-based radiopacifiers are unsuitable due to metal accumulation risks. CLINICAL RELEVANCE: This study highlights the need for further in vivo studies on endodontic sealers' chemical, biological, and physical behaviors and their systemic migration.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Restorative Dentistry - Endodontics, Faculdade de Odontologia de Piracicaba, Universidade Estadual de Campinas, Piracicaba, SP, Brazil.
- Department of Biosciences - Pharmacology, Anesthesiology and Therapeutics, Faculdade de Odontologia de Piracicaba, Universidade Estadual de Campinas, Piracicaba, SP, Brazil.
- Department of Oral Diagnosis - Division of Oral Radiology, Faculdade de Odontologia de Piracicaba, Universidade Estadual de Campinas, Piracicaba, SP, Brazil.
- Department of Diagnostics and Surgery, Universidade Estadual Paulista Julio de Mesquita Filho - Faculdade de Odontologia de Araçatuba, Araçatuba, SP, Brazil.
- Department of Basic Sciences, Universidade Estadual Paulista Julio de Mesquita Filho - Faculdade de Odontologia de Araçatuba, Araçatuba, SP, Brazil.
- Department of Mining and Petroleum Engineering, Escola Politécnica, Universidade de São Paulo, São Paulo, SP, Brazil.
Förderung
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
- Fundação de Amparo à Pesquisa do Estado de São Paulo
Zitieren
APA
Janini, A. C. P., Moraes, B. F., Pelepenko, L. E., Dos Santos, V. A. B., Barros-Costa, M., Malosá, G. F., Batista, F. R. S., Meira, J. A. S., Matsumoto, M. A., Antunes, T. B. M., Darin Filho, G., Haiter Neto, F., Gomes, B. P. F. A., & Marciano, M. A. (2025). Physicochemical properties and biological interaction of calcium silicate-based sealers - in vivo model. Clinical Oral Investigations. https://doi.org/10.1007/s00784-025-06150-6
Vancouver
Janini ACP, Moraes BF, Pelepenko LE, Dos Santos VAB, Barros-Costa M, Malosá GF, et al. Physicochemical properties and biological interaction of calcium silicate-based sealers - in vivo model. Clinical Oral Investigations. 2025. doi:10.1007/s00784-025-06150-6
BibTeX
@article{Janini2025,
author = {Janini, Ana Cristina Padilha and Moraes, Brenda Fornazaro and Pelepenko, Lauter Eston and Dos Santos, Victor Augusto Benedicto and Barros-Costa, Matheus and Malosá, Gabriela Fernanda and Batista, Fábio Roberto de Souza and Meira, Juliana de Aguiar Silveira and Matsumoto, Mariza Akemi and Antunes, Thiago Bessa Marconato and Darin Filho, Gaspar and Haiter Neto, Francisco and Gomes, Brenda Paula Figueiredo de Almeida and Marciano, Marina Angélica},
title = {Physicochemical properties and biological interaction of calcium silicate-based sealers - in vivo model},
journal = {Clinical Oral Investigations},
year = {2025},
doi = {10.1007/s00784-025-06150-6}
}
EUVIMED