EUVIMEDEUVIMED entdecken
Vergleichsstudie

Accuracy of web-based automated versus digital manual cephalometric landmark identification

Mais Sadek, Omar Alaskari, Ahmad Hamdan

Clinical Oral Investigations · 2024

DOI: 10.1007/s00784-024-06021-6 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Clinical Oral Investigations, 2024. Verfasst von Mais Sadek und 2 weiteren Autor:innen. Beteiligte Einrichtung: Program Director and Assistant Professor of Orthodontics, College of Dental Medicine, University of Sharjah, Sharjah, United Arab Emirates. maismedha…. Hauptthemen laut MEDLINE: Cephalometry, Anatomic Landmarks, Software, Internet. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

AIM: The purpose of this study was to assess the accuracy of two web-based automated cephalometric landmark identification and analysis programs. Manual landmark identification using Dolphin Imaging software was used as reference. MATERIALS AND METHODS: 105 cephalograms were selected and divided into three groups of 35 subjects each, Class I, II and III. Radiographs were traced using Dolphin imaging software. WebCeph™ (South Korea) and Cephio™ (Poland) were used for the automated cephalometric analysis. Bland-Altman limits of agreement and the concordance correlation coefficient (CCC) were calculated. Kruskal Wallis test was used to compare the accuracy of WebCeph™ and Cephio™ measurements between the three groups. Mann-Whitney U test was used to compare the absolute difference between cephalometric measurements obtained using WebCeph™ and Cephio™. RESULTS: The mean difference (MD) between AI and manually-derived measurements was less than 1 mm/degree and ranged from 0.01 to 0.8 except for upper lip protrusion (MD 1.35°), nasolabial angle (MD 5.01°), SN-GoGn (MD 1.41°), Ramus height (MD 1.46°), and IMPA (MD 1.94°). The mean CCC was 0.91 (range 0.60 to 0.96). No statistically significant differences were found between the three malocclusion groups for most of the measurements (P > 0.05). CONCLUSIONS: For most of the measurements, automated cephalometric measurements were clinically acceptable. Few differences were found between Webceph™ and Cephio™ for most measurements. Measurements including SNA, SN-PP, IMPA as well as soft tissue measurements require extra consideration and manual adjustment of respective landmarks for higher precision and improved efficiency.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CephalometryAnatomic LandmarksSoftwareInternetHumansMaleFemaleImage Processing, Computer-AssistedRepublic of Korea

Stichwörter der Autor:innen

Artificial intelligenceCephalometricCephioWebceph

Autor:innen und Institutionen

  • Program Director and Assistant Professor of Orthodontics, College of Dental Medicine, University of Sharjah, Sharjah, United Arab Emirates. maismedhat@asfd.asu.edu.eg.
  • Assistant Professor of Orthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt. maismedhat@asfd.asu.edu.eg.
  • Resident, College of Dental Medicine, University of Sharjah, Sharjah, United Arab Emirates.
  • Dean and Professor of Orthodontics, College of Dental Medicine, University of Sharjah, United Arab Emirates, Sharjah, United Arab Emirates.
  • Professor of Orthodontics, University of Jordan, Amman, Jordan.

Zitieren

APA

Sadek, M., Alaskari, O., & Hamdan, A. (2024). Accuracy of web-based automated versus digital manual cephalometric landmark identification. Clinical Oral Investigations. https://doi.org/10.1007/s00784-024-06021-6

Vancouver

Sadek M, Alaskari O, Hamdan A. Accuracy of web-based automated versus digital manual cephalometric landmark identification. Clinical Oral Investigations. 2024. doi:10.1007/s00784-024-06021-6

BibTeX
@article{Sadek2024,
  author = {Sadek, Mais and Alaskari, Omar and Hamdan, Ahmad},
  title = {Accuracy of web-based automated versus digital manual cephalometric landmark identification},
  journal = {Clinical Oral Investigations},
  year = {2024},
  doi = {10.1007/s00784-024-06021-6}
}
Kostenlos starten →