Fachartikel in der Zeitschrift Clinical Oral Investigations, online erschienen am 14.03.2024. Verfasst von Karin Christine Huth und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Conservative Dentistry and Periodontology, University Hospital, LMU Munich, Goethestr. 70, 80336, Munich, Germany. Karin.Huth@med.uni-m…. Hauptthemen laut MEDLINE: Tooth, Endodontics. Die Arbeit wurde bisher 32-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinik München.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To assess root canal localization accuracy using a dynamic approach, surgical guides and freehand technique in vitro. Materials and methods Access cavities were prepared for 4 different 3D printed tooth types by 4 operators ( n = 144). Deviations from the planning in angle and bur positioning were compared and operating time as well as tooth substance loss were evaluated (Kruskal-Wallis Test, ANOVA). Operating method, tooth type, and operator effects were analyzed (partial eta-squared statistic).

Results

Angle deviation varied significantly between the operating methods ( p < .0001): freehand (9.53 ± 6.36°), dynamic (2.82 ± 1.8°) and static navigation (1.12 ± 0.85°). The highest effect size was calculated for operating method (ηP²=0.524), followed by tooth type (0.364), and operator (0.08). Regarding deviation of bur base and tip localization no significant difference was found between the methods. Operating method mainly influenced both parameters (ηP²=0.471, 0.379) with minor effects of tooth type (0.157) and operator. Freehand technique caused most substance loss ( p < .001), dynamic navigation least ( p < .0001). Operating time was the shortest for freehand followed by static and dynamic navigation.

Conclusions

Guided endodontic access may aid in precise root canal localization and save tooth structure. Clinical relevance Although guided endodontic access preparation may require more time compared to the freehand technique, the guided navigation is more accurate and saves tooth structure.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ToothEndodonticsRoot Canal PreparationDental Pulp CavityCone-Beam Computed TomographyPrinting, Three-Dimensional

Stichwörter der Autor:innen

3D printingAccess cavity preparationDynamic navigationGuided endodonticsStatic navigationSurgical guideTemplate

Autor:innen und Institutionen

  • Department of Conservative Dentistry and Periodontology, University Hospital, LMU Munich, Goethestr. 70, 80336, Munich, Germany. Karin.Huth@med.uni-muenchen.de.
  • Department of Conservative Dentistry and Periodontology, University Hospital, LMU Munich, Goethestr. 70, 80336, Munich, Germany.
  • Department of Prosthetic Dentistry, Faculty of Medicine, University of Cologne, University Hospital Cologne, Kerpener Str. 32, 50931, Cologne, Germany.

Förderung

  • Universitätsklinik München

Zitieren

APA

Huth, K. C., Borkowski, L., Liebermann, A., Berlinghoff, F., Hickel, R., Schwendicke, F., & Reymus, M. (2024). Comparing accuracy in guided endodontics: dynamic real-time navigation, static guides, and manual approaches for access cavity preparation – an in vitro study using 3D printed teeth. Clinical Oral Investigations, 28(4). https://doi.org/10.1007/s00784-024-05603-8

Vancouver

Huth KC, Borkowski L, Liebermann A, Berlinghoff F, Hickel R, Schwendicke F, et al. Comparing accuracy in guided endodontics: dynamic real-time navigation, static guides, and manual approaches for access cavity preparation – an in vitro study using 3D printed teeth. Clinical Oral Investigations. 2024;28(4). doi:10.1007/s00784-024-05603-8

BibTeX
@article{Huth2024,
  author = {Huth, Karin Christine and Borkowski, Lukas and Liebermann, Anja and Berlinghoff, Frank and Hickel, Reinhard and Schwendicke, Falk and Reymus, Marcel},
  title = {Comparing accuracy in guided endodontics: dynamic real-time navigation, static guides, and manual approaches for access cavity preparation – an in vitro study using 3D printed teeth},
  journal = {Clinical Oral Investigations},
  year = {2024},
  volume = {28},
  number = {4},
  doi = {10.1007/s00784-024-05603-8}
}
Kostenlos starten →