Visualization of instruments–endoscope interference in neuroendoscopic surgery
Acta Neurochirurgica · 19.08.2026 · 168 (1)
DOI: 10.1007/s00701-026-07010-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Neurochirurgica, online erschienen am 19.08.2026. Verfasst von Kento Takahara und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Ashikaga Red Cross Hospital, 284-1 Yobe-Cho, Ashikaga-Shi, Tochigi, 326-0843, Japan. pami529@yahoo.co.jp. Hauptthemen laut MEDLINE: Neuroendoscopy, Neuroendoscopes, Surgical Instruments, Endoscopes. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
In neuroendoscopic surgeries, instrument-endoscope interference can prevent instruments from reaching certain areas visible within the endoscopic view, leading to the perception of a “restricted zone” (RZ). We aimed to visualize and quantitatively evaluate the RZ, thereby enabling intuitive understanding of instrument–endoscope interference.
Methods
Cadaver studies were conducted to investigate the typical endoscope-target distance, a key factor affecting RZ formation. Based on this distance, a simulated surgical field was created using an endoscope and light source, with light projected from the instrument’s entry point. Illuminated regions represented areas accessible to a straight instrument, while shadows cast by the endoscope or other instruments indicated unreachable areas—RZs—visualized within the endoscopic view. The study examined changes in the RZs under various conditions.
Results
In cadaver experiments, the typical endoscope-target distance was approximately 7–20 mm. The visualized RZ consistently appeared on the side opposite the instrument in the endoscopic view regardless of endoscopic tip movement. Under typical conditions, the RZ occupied 6.0–28.2% of the endoscopic field of view. Oblique scope or thin scope altered RZ. In simulated three-hand surgery, additional RZs generated by instruments resulted in a more complex RZ pattern, according to the entry-site configuration of the endoscope and the two instruments.
Conclusions
RZ was successfully visualized and quantitatively characterized. Instrument–endoscope interference is largely governed by the positional relationship of instruments and the endoscope at the entry and by their appearance within the endoscopic field of view. Strategic control of these factors may therefore help minimize interference.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurosurgery, Ashikaga Red Cross Hospital, 284-1 Yobe-Cho, Ashikaga-Shi, Tochigi, 326-0843, Japan. pami529@yahoo.co.jp.
- Department of Neurosurgery, Keio University School of Medicine, Tokyo, Japan. pami529@yahoo.co.jp.
- Department of Neurosurgery, Ashikaga Red Cross Hospital, 284-1 Yobe-Cho, Ashikaga-Shi, Tochigi, 326-0843, Japan.
- Department of Neurosurgery, Keio University School of Medicine, Tokyo, Japan.
ORCID-Profile: Kento Takahara
Zitieren
APA
Takahara, K., Ogino, M., Ueda, R., Miwa, T., Nishimoto, M., Yamada, N., & Toda, M. (2026). Visualization of instruments–endoscope interference in neuroendoscopic surgery. Acta Neurochirurgica, 168(1). https://doi.org/10.1007/s00701-026-07010-2
Vancouver
Takahara K, Ogino M, Ueda R, Miwa T, Nishimoto M, Yamada N, et al. Visualization of instruments–endoscope interference in neuroendoscopic surgery. Acta Neurochirurgica. 2026;168(1). doi:10.1007/s00701-026-07010-2
BibTeX
@article{Takahara2026,
author = {Takahara, Kento and Ogino, Masahiro and Ueda, Ryo and Miwa, Tomoru and Nishimoto, Masaaki and Yamada, Nobuhiro and Toda, Masahiro},
title = {Visualization of instruments–endoscope interference in neuroendoscopic surgery},
journal = {Acta Neurochirurgica},
year = {2026},
volume = {168},
number = {1},
doi = {10.1007/s00701-026-07010-2}
}
EUVIMED