Clinical utility of SPECT/CT radionuclide shuntgraphy in suspected ventriculoperitoneal shunt dysfunction
Acta Neurochirurgica · 2026
DOI: 10.1007/s00701-026-06998-x ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Neurochirurgica, 2026. Verfasst von Zixuan Wei und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Zhongnan Hospital of Wuhan University, Donghu Road 169, Wuhan, 430071, China. Hauptthemen laut MEDLINE: Ventriculoperitoneal Shunt, Single Photon Emission Computed Tomography Computed Tomography, Hydrocephalus, Equipment Failure. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Objective
This study aims to develop and validate a more efficient diagnostic system for suspected ventriculoperitoneal shunt dysfunction by integrating traditional radionuclide shuntgraphy with SPECT imaging.
Methods
This retrospective study examined patients with suspected shunt malfunction admitted to our neurosurgery department from 2021 to 2024, who underwent SPECT/CT imaging of the ventricular shunt. SPECT/CT results were categorized as three groups based on tracer behavior: normal shunt function, partial obstruction, and shunt obstruction. Baseline data, imaging characteristics and clinical management were recorded. Diagnostic agreement with surgery was analyzed only in patients who underwent revision, the only subgroup with a definitive intraoperative reference standard.
Result
A study of 46 SPECT/CT images from 42 patients found 14 normal shunt functions, 23 with partial obstruction, and 9 with complete obstruction. Nineteen patients underwent surgery, and SPECT/CT demonstrated good agreement with intraoperative findings (16/19), corresponding to a sensitivity of 88.9%. Specificity could not be reliably estimated because there were no true-negative surgical cases. Thin-slice CT scans assessing shunt catheter position and morphology revealed abnormalities such as malposition of the ventricular or abdominal catheter, tortuosity in the abdominal segment, and obstruction or rupture of the catheter body. Abnormal shunt tube positioning or morphology was more prevalent in the obstruction group ( p = 0.0083).
Conclusion
In this heterogeneous clinical population, the SPECT/CT shunt imaging diagnostic system prove0d feasible and clinically informative.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurosurgery, Zhongnan Hospital of Wuhan University, Donghu Road 169, Wuhan, 430071, China.
- Brain Research Center, Zhongnan Hospital of Wuhan University, Wuhan, 430071, China.
- Department of Nuclear Medicine, Zhongnan Hospital of Wuhan University, Wuhan University, Donghu Road 169, Wuhan, 430071, China.
- Department of Neurosurgery, Zhongnan Hospital of Wuhan University, Donghu Road 169, Wuhan, 430071, China. zhangtingbao@126.com.
- Brain Research Center, Zhongnan Hospital of Wuhan University, Wuhan, 430071, China. zhangtingbao@126.com.
- Department of Nuclear Medicine, Zhongnan Hospital of Wuhan University, Wuhan University, Donghu Road 169, Wuhan, 430071, China. mjshen@foxmail.com.
ORCID-Profile: Jincao Chen
Zitieren
APA
Wei, Z., Pi, Z., Zhang, J., Xu, C., Jiang, L., Li, W., Zhang, T., Shen, M., & Chen, J. (2026). Clinical utility of SPECT/CT radionuclide shuntgraphy in suspected ventriculoperitoneal shunt dysfunction. Acta Neurochirurgica. https://doi.org/10.1007/s00701-026-06998-x
Vancouver
Wei Z, Pi Z, Zhang J, Xu C, Jiang L, Li W, et al. Clinical utility of SPECT/CT radionuclide shuntgraphy in suspected ventriculoperitoneal shunt dysfunction. Acta Neurochirurgica. 2026. doi:10.1007/s00701-026-06998-x
BibTeX
@article{Wei2026,
author = {Wei, Zixuan and Pi, Ziwei and Zhang, Jibo and Xu, Chengshi and Jiang, Linglong and Li, Wenyu and Zhang, Tingbao and Shen, Meijuan and Chen, Jincao},
title = {Clinical utility of SPECT/CT radionuclide shuntgraphy in suspected ventriculoperitoneal shunt dysfunction},
journal = {Acta Neurochirurgica},
year = {2026},
doi = {10.1007/s00701-026-06998-x}
}
EUVIMED