Quantitative assessment of cranial fixation stability using a sensor-equipped head fixation device in neurosurgical simulations
Acta Neurochirurgica · 2025
DOI: 10.1007/s00701-025-06692-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Neurochirurgica, 2025. Verfasst von René Machts und 2 weiteren Autor:innen. Beteiligte Einrichtung: Black Forest Medical GmbH, Freiburg, Germany. r.machts@blackforestmedical.com. Hauptthemen laut MEDLINE: Craniotomy, Neurosurgical Procedures, Neuronavigation, Skull. Die Arbeit nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: German Federal Ministry of Education and Research.
Abstract (Originalsprache)
PURPOSE: Reliable head fixation is essential for accuracy in cranial neurosurgical procedures, particularly when using neuronavigation systems. While traditional skull clamps are designed to ensure rigid immobilization, undiscovered movement of patient´s head under external forces can undermine surgical precision. METHODS: In this study, we investigate the biomechanical performance of a head fixation device equipped with force and angle sensors. Using seven cadaveric heads and an external force applicator, we quantified resistance against the external force, the axial force at each pin and angular displacement of the two-pin rocker. The movement of head across three clinically relevant head positions for craniotomy: prone, middle fossa, and pterional was optically recorded by a neuronavigation system. RESULTS: In the pterional position, the horizontal orientation of the two-pin rocker resisted significantly higher external shear forces (575.1 N, SD: 202.3 N) than the vertical orientation (427.2 N, SD: 105.9 N; p = 0.0081). Correspondingly, angular displacement of the two-pin rocker was lower in the horizontal orientation (0.48°, SD: 0.65°) than in the vertical orientation (1.15°, SD: 0.76°; p = 9.92 · 10-5). No statistically significant differences were observed in the prone or middle fossa positions for the external shear forces. CONCLUSION: These results suggest that optimal two-pin rocker orientation can mitigate slippage and angular drift, improving intraoperative reliability. This study provides a foundation for developing a quantitative stability model and evidence-based recommendations for skull clamp application in neurosurgical practice.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Black Forest Medical GmbH, Freiburg, Germany. r.machts@blackforestmedical.com.
- Black Forest Medical GmbH, Freiburg, Germany.
- Neurosurgery department, Hôpitaux Universitaires Genève, Geneva, Switzerland.
Förderung
- German Federal Ministry of Education and Research
Zitieren
APA
Machts, R., Gareiss, L., & Visentin, A. (2025). Quantitative assessment of cranial fixation stability using a sensor-equipped head fixation device in neurosurgical simulations. Acta Neurochirurgica. https://doi.org/10.1007/s00701-025-06692-4
Vancouver
Machts R, Gareiss L, Visentin A. Quantitative assessment of cranial fixation stability using a sensor-equipped head fixation device in neurosurgical simulations. Acta Neurochirurgica. 2025. doi:10.1007/s00701-025-06692-4
BibTeX
@article{Machts2025,
author = {Machts, René and Gareiss, Livia and Visentin, Alissa},
title = {Quantitative assessment of cranial fixation stability using a sensor-equipped head fixation device in neurosurgical simulations},
journal = {Acta Neurochirurgica},
year = {2025},
doi = {10.1007/s00701-025-06692-4}
}
EUVIMED