Risk factors for in-stent stenosis after flow-diverter implantation for intracranial aneurysm: a single center analysis of 161 consecutive patients
Acta Neurochirurgica · 17.07.2025 · 167 (1)
DOI: 10.1007/s00701-025-06597-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Neurochirurgica, online erschienen am 17.07.2025. Verfasst von Rabab Alshahrani und 4 weiteren Autor:innen. Beteiligte Einrichtung: Division of Neuroradiology, Joint Department of Medical Imaging, Toronto Western Hospital, University Health Network, Toronto, ON, Canada. Hauptthemen laut MEDLINE: Intracranial Aneurysm, Stents, Endovascular Procedures. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
INTRODUCTION: Flow diverters (FD) are used for the treatment of intracranial aneurysms, by redirecting flow and serving as a scaffold for endothelial coverage of the aneurysm ostium. However, in-stent stenosis has been observed in some patients treated with these devices, the cause of which and the epidemiology remaining elusive. In the current study we aimed to elucidate potential factors leading to higher degree of in-stent stenosis including gender, location, and type of FD. METHODS: The authors queried their institutional Electronic Health Record (EHR) for all patients undergoing FD for intracranial saccular aneurysms. We excluded cases where an FD was performed for a dissecting aneurysm, or other indications. We also excluded patients who had no available follow up. RESULTS: We identified 161 patients undergoing FD for aneurysms, with a mean age of 57.4 (SD = 12.94) and141 (87.6%) of which were females. A total of 24 patients (14.9%) had an in-stent stenosis at a median interval of 10 months; 9 (5.6%) had a severe (i.e. symptomatic or requiring treatment) stenosis. When subsetting for females, we found that females with any in-stent stenosis were significantly younger compared to those without stenosis (51.045, SD = 15.7 vs 58.5, SD = 12.31, p = 0.013). Females with severe in-stent stenosis were even younger (42.2, SD = 14.2 vs 58.3, SD = 12.54; p < 0.001) compared to the rest of the females. Patients presenting with ruptured aneurysm had a higher rate of severe in-stent stenosis (16.7%, n = 4/24, p = 0.014). Regarding devices, patients who underwent treatment with a high-braid FD were more likely to have severe in-stent stenosis (18.8%, n = 3/16; p = 0.016). CONCLUSION: Our findings indicate that younger age, presentation with rupture and high-braid FD may be associated with higher risk of severe in-stent stenosis. These findings may provide more insight into the selection of treatment modality and/or device in patients undergoing management of their cerebral aneurysms.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Neuroradiology, Joint Department of Medical Imaging, Toronto Western Hospital, University Health Network, Toronto, ON, Canada.
- Department of Neurosurgery, Toronto Western Hospital, University Health Network, Toronto, ON, M5G 2C4, Canada.
- Trillium Health Partners, Mississauga, ON, L4Y 4C5, Canada.
- Department of Neurosurgery, Thomas Jefferson University, Philadelphia, PA, USA.
- Department of Neuroradiology, Beaumont Hospital, Dublin, BL6 4LA, Ireland.
- Division of Neuroradiology, Joint Department of Medical Imaging, Toronto Western Hospital, University Health Network, Toronto, ON, Canada. timo.krings@lahey.org.
Zitieren
APA
Alshahrani, R., Karadimas, S., Alvi, M. A., Nicholson, P. J., & Krings, T. (2025). Risk factors for in-stent stenosis after flow-diverter implantation for intracranial aneurysm: a single center analysis of 161 consecutive patients. Acta Neurochirurgica, 167(1). https://doi.org/10.1007/s00701-025-06597-2
Vancouver
Alshahrani R, Karadimas S, Alvi MA, Nicholson PJ, Krings T. Risk factors for in-stent stenosis after flow-diverter implantation for intracranial aneurysm: a single center analysis of 161 consecutive patients. Acta Neurochirurgica. 2025;167(1). doi:10.1007/s00701-025-06597-2
BibTeX
@article{Alshahrani2025,
author = {Alshahrani, Rabab and Karadimas, Spyridon and Alvi, Mohammed Ali and Nicholson, Patrick Joseph and Krings, Timo},
title = {Risk factors for in-stent stenosis after flow-diverter implantation for intracranial aneurysm: a single center analysis of 161 consecutive patients},
journal = {Acta Neurochirurgica},
year = {2025},
volume = {167},
number = {1},
doi = {10.1007/s00701-025-06597-2}
}
EUVIMED