EUVIMEDEUVIMED entdecken
Multizentrische StudieOpen Access · CC BY 4.0

The NeVa Net stent-retriever – initial report of 20 cases from two high volume centres

Pervinder Bhogal, Marco Mancuso-Marcello, Rory Fairhead, Nadia Shah, Keng Siang Lee, Christos Nikola, Katherine Parkin, Giovanna Klefti, Levansri Makalanda, Ken Wong, Joe Lansley, Michael Przyszlak und 3 weitere

Acta Neurochirurgica · 2025

DOI: 10.1007/s00701-025-06586-5 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Acta Neurochirurgica, 2025. Verfasst von Pervinder Bhogal und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Interventional Neuroradiology, The Royal London Hospital, Whitechapel Road, London, E1 1BB, UK. Hauptthemen laut MEDLINE: Stents, Thrombectomy. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Various different technologies have been developed to optimise the mechanical thrombectomy procedure and first pass recanalisation. We report our initial experience with the NeVa NET – a novel stent-retriever with built in distal microfiltration net. Materials and methods We performed a retrospective review of our prospectively maintained databases to identify all patients treated with the NeVa NET 4 × 30 mm device. We recorded the baseline demographics, NIHSS, ASPECT score and clot characteristics, first pass and final eTICI scores, complications and 90 day mRS.

Results

We identified 20 patients (50% male), average age 67.9 ± 16.2 yrs, and median NIHSS 18 (range 6–29). 30% of patients received tPA. Average clot length was 21.6 ± 8.9 mm and median ASPECT score 9 (range 5–10). In 18 cases the NeVa NET could be tracked into position, however, in 2 cases it could not be tracked into position within the 0,021inch microcatheter. First pass recanalization (eTICI ≥ 2c) was seen in 94% (n = 17) and the average number of NeVa NET passes was 1. A final eTICI score of ≥ 2c was achieved in 17 patients (94%). There were no emboli to new territories. No cases of vessel rupture or dissections occured due to the NeVa NET. 50% of patients achieved mRS 0–2. SAH was seen in 31.3% and SICH in 6.3% of the 16 patients for whom a 24 h CT head was available.

Conclusion

The NeVa Net stent-retriever is uniquely designed to prevent distal embolisation and our initial experience demonstrates a very high FPE and mFPE. We believe this is the first publication on the use of this novel technology and larger studies are warranted.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

StentsThrombectomyHumansMaleFemaleAgedRetrospective StudiesMiddle AgedAged, 80 and overTreatment OutcomeHospitals, High-Volume

Stichwörter der Autor:innen

First pass effectLarge vessel occlusionMechanical thrombectomyMicrofilterNeVa NETStroke

Autor:innen und Institutionen

  • Department of Interventional Neuroradiology, The Royal London Hospital, Whitechapel Road, London, E1 1BB, UK.
  • The London School of Medicine and Dentistry, Queen Mary University, Turner Street, London, UK.
  • Department of Basic and Clinical Neurosciences, Maurice Wohl Clinical Neuroscience Institute, Institute of Psychiatry, Psychology and Neuroscience (IoPPN), King's College London, London, UK. kengsiang.lee1@nhs.net.
  • Department of Neurosurgery, National Neuroscience Institute, Singapore, Singapore. kengsiang.lee1@nhs.net.
  • Department of Stroke, The Royal London Hospital, Whitechapel Road, London, UK.
  • Department of Interventional Neuroradiology, UHC Sisters of Mercy, Zagreb, Croatia.

Zitieren

APA

Bhogal, P., Mancuso-Marcello, M., Fairhead, R., Shah, N., Lee, K. S., Nikola, C., Parkin, K., Klefti, G., Makalanda, L., Wong, K., Lansley, J., Przyszlak, M., Spooner, O., Čulo, B., & Kalousek, V. (2025). The NeVa Net stent-retriever – initial report of 20 cases from two high volume centres. Acta Neurochirurgica. https://doi.org/10.1007/s00701-025-06586-5

Vancouver

Bhogal P, Mancuso-Marcello M, Fairhead R, Shah N, Lee KS, Nikola C, et al. The NeVa Net stent-retriever – initial report of 20 cases from two high volume centres. Acta Neurochirurgica. 2025. doi:10.1007/s00701-025-06586-5

BibTeX
@article{Bhogal2025,
  author = {Bhogal, Pervinder and Mancuso-Marcello, Marco and Fairhead, Rory and Shah, Nadia and Lee, Keng Siang and Nikola, Christos and Parkin, Katherine and Klefti, Giovanna and Makalanda, Levansri and Wong, Ken and Lansley, Joe and Przyszlak, Michael and Spooner, Oliver and Čulo, Branimir and Kalousek, Vladimir},
  title = {The NeVa Net stent-retriever – initial report of 20 cases from two high volume centres},
  journal = {Acta Neurochirurgica},
  year = {2025},
  doi = {10.1007/s00701-025-06586-5}
}
Kostenlos starten →