Clinical experiences and accuracy of stereoelectroencephalography using the robotic arm Cirq
Acta Neurochirurgica · 2025
DOI: 10.1007/s00701-025-06541-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Neurochirurgica, 2025. Verfasst von Kohei Kanaya und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, 390-8621, Nagano, Japan. kanaya@shinshu-u.ac.jp. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Electroencephalography, Stereotaxic Techniques, Drug Resistant Epilepsy. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Shinshu University.
Abstract (Originalsprache)
Background
Robot-assisted stereoelectroencephalography (SEEG) has become increasingly popular worldwide. Robotic arm Cirq (BrainLab, Munich, Germany) is an optional instrument for SEEG. This study aimed to evaluate the accuracy of electrode implantation using Cirq.
Methods
Data were retrospectively collected from 10 consecutive SEEG cases from July 2022 to August 2024 at our institute. Two cases of simultaneous SEEG and grid implantation via craniotomy were excluded. Eight SEEG cases (37 depth electrodes) were included in this study. We evaluated the accuracy of the electrode placement. The distances between the planned and actual site of entry and the target were measured in the anterior-posterior (Xe, Xt) and cranial-caudal (Ye, Yt) directions. The distance between the planned and the actual target site was measured at the surface depth (Zt). The two-dimensional differences of the entry (De 2 ) and target (Dt 2 ) and the three-dimensional differences, including the depth parameter of the target (Dt), were measured. The two-dimensional and three-dimensional Euclidean distances (ED 2 , ED) were also calculated.
Results
The differences between the planned entry and the actual entry in Xe and Ye were 2.5 ± 1.6 mm and -0.6 ± 1.8 mm, respectively. De 2 was 3.2 ± 1.4 mm. The differences between the planned target and the actual target in Xt, Yt, and Zt were 2.1 ± 1.5 mm, 0.5 ± 1.5 mm, and 1.4 ± 2.9 mm, respectively. Dt 2 and Dt were 2.7 ± 1.4 mm and 4.1 ± 1.7 mm, respectively. ED 2 and ED were 1.8 ± 1.1 mm and 3.4 ± 1.8 mm, respectively.
Conclusions
We reported our initial experience with a high accuracy and features of the Cirq robotic arm for SEEG procedures using the standard surface matching method.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurosurgery, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, 390-8621, Nagano, Japan. kanaya@shinshu-u.ac.jp.
- Epilepsy Center, Shinshu University Hospital, Matsumoto, Nagano, Japan. kanaya@shinshu-u.ac.jp.
- Department of Neurosurgery, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, 390-8621, Nagano, Japan.
- Department of Clinical Engineer, Shinshu University Hospital, Matsumoto, Nagano, Japan.
- Epilepsy Center, Shinshu University Hospital, Matsumoto, Nagano, Japan.
- Department of Pediatrics, Shinshu University School of Medicine, Matsumoto, Nagano, Japan.
ORCID-Profile: Kohei Kanaya
Förderung
- Shinshu University
Zitieren
APA
Kanaya, K., Nakamura, A., Abe, D., Sato, Y., Wakabayashi, M., Shigehara, T., Watanabe, D., Yoshizawa, Y., Fukuyama, T., & Horiuchi, T. (2025). Clinical experiences and accuracy of stereoelectroencephalography using the robotic arm Cirq. Acta Neurochirurgica. https://doi.org/10.1007/s00701-025-06541-4
Vancouver
Kanaya K, Nakamura A, Abe D, Sato Y, Wakabayashi M, Shigehara T, et al. Clinical experiences and accuracy of stereoelectroencephalography using the robotic arm Cirq. Acta Neurochirurgica. 2025. doi:10.1007/s00701-025-06541-4
BibTeX
@article{Kanaya2025,
author = {Kanaya, Kohei and Nakamura, Asuka and Abe, Daishiro and Sato, Yutaro and Wakabayashi, Mana and Shigehara, Tomoya and Watanabe, Daichi and Yoshizawa, Yuki and Fukuyama, Tetsuhiro and Horiuchi, Tetsuyoshi},
title = {Clinical experiences and accuracy of stereoelectroencephalography using the robotic arm Cirq},
journal = {Acta Neurochirurgica},
year = {2025},
doi = {10.1007/s00701-025-06541-4}
}
EUVIMED