EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Fast simulation of hemodynamics in intracranial aneurysms for clinical use

Daniel Deuter, Amer Haj, Alexander Brawanski, Lars Krenkel, Nils-Ole Schmidt, Christian Doenitz

Acta Neurochirurgica · 2025

DOI: 10.1007/s00701-025-06469-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta Neurochirurgica, 2025. Verfasst von Daniel Deuter und 5 weiteren Autor:innen. Beteiligte Einrichtung: Klinik und Poliklinik für Neurochirurgie, University Hospital Regensburg, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Germany. daniel.deuter@klin…. Hauptthemen laut MEDLINE: Intracranial Aneurysm, Hemodynamics, Computer Simulation. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 94 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Regensburg.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

A widely accepted tool to assess hemodynamics, one of the most important factors in aneurysm pathophysiology, is Computational Fluid Dynamics (CFD). As current workflows are still time consuming and difficult to operate, CFD is not yet a standard tool in the clinical setting. There it could provide valuable information on aneurysm treatment, especially regarding local risks of rupture, which might help to optimize the individualized strategy of neurosurgical dissection during microsurgical aneurysm clipping.

Method

We established and validated a semi-automated workflow using 3D rotational angiographies of 24 intracranial aneurysms from patients having received aneurysm treatment at our centre. Reconstruction of vessel geometry and generation of volume meshes was performed using AMIRA 6.2.0 and ICEM 17.1. For solving ANSYS CFX was used. For validational checks, tests regarding the volumetric impact of smoothing operations, the impact of mesh sizes on the results (grid convergence), geometric mesh quality and time tests for the time needed to perform the workflow were conducted in subgroups.

Results

Most of the steps of the workflow were performed directly on the 3D images requiring no programming experience. The workflow led to final CFD results in a mean time of 22 min 51.4 s (95%-CI 20 min 51.562 s–24 min 51.238 s, n = 5). Volume of the geometries after pre-processing was in mean 4.46% higher than before in the analysed subgroup (95%-CI 3.43–5.50%). Regarding mesh sizes, mean relative aberrations of 2.30% (95%-CI 1.51–3.09%) were found for surface meshes and between 1.40% (95%-CI 1.07–1.72%) and 2.61% (95%-CI 1.93–3.29%) for volume meshes. Acceptable geometric mesh quality of volume meshes was found.

Conclusions

We developed a semi-automated workflow for aneurysm CFD to benefit from hemodynamic data in the clinical setting. The ease of handling opens the workflow to clinicians untrained in programming. As previous studies have found that the distribution of hemodynamic parameters correlates with thin-walled aneurysm areas susceptible to rupture, these data might be beneficial for the operating neurosurgeon during aneurysm surgery, even in acute cases.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Intracranial AneurysmHemodynamicsComputer SimulationHumansImaging, Three-DimensionalCerebral AngiographyFemaleMaleHydrodynamicsMiddle AgedWorkflowAged

Stichwörter der Autor:innen

CFDIntracranial aneurysmIntraoperativeLocal risk assessmentRupture risk evaluationThin-walled regions

Autor:innen und Institutionen

  • Klinik und Poliklinik für Neurochirurgie, University Hospital Regensburg, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Germany. daniel.deuter@klinik.uni-regensburg.de.
  • Klinik und Poliklinik für Neurochirurgie, University Hospital Regensburg, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Germany.
  • Regensburg Center of Biomedical Engineering (RCBE), OTH Regensburg and University of Regensburg, 93053, Regensburg, Germany.

Förderung

  • Universitätsklinikum Regensburg

Zitieren

APA

Deuter, D., Haj, A., Brawanski, A., Krenkel, L., Schmidt, N. O., & Doenitz, C. (2025). Fast simulation of hemodynamics in intracranial aneurysms for clinical use. Acta Neurochirurgica. https://doi.org/10.1007/s00701-025-06469-9

Vancouver

Deuter D, Haj A, Brawanski A, Krenkel L, Schmidt NO, Doenitz C. Fast simulation of hemodynamics in intracranial aneurysms for clinical use. Acta Neurochirurgica. 2025. doi:10.1007/s00701-025-06469-9

BibTeX
@article{Deuter2025,
  author = {Deuter, Daniel and Haj, Amer and Brawanski, Alexander and Krenkel, Lars and Schmidt, Nils-Ole and Doenitz, Christian},
  title = {Fast simulation of hemodynamics in intracranial aneurysms for clinical use},
  journal = {Acta Neurochirurgica},
  year = {2025},
  doi = {10.1007/s00701-025-06469-9}
}
Kostenlos starten →