EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Radiation exposure and safety in low-dose CT-guided glycerol rhizotomy for trigeminal Neuralgia outside the operating room

Jiri Dostal iD, Jan Baxa iD, Jana Stepankova iD, Miroslav Seidl iD, Jan Mracek iD, Pavel Lavicka iD, Tomas Malkus iD, Vladimir Priban iD

Acta Neurochirurgica · 2024

DOI: 10.1007/s00701-024-06364-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta Neurochirurgica, 2024. Verfasst von Jiri Dostal und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Faculty of Medicine in Pilsen, Charles University, University Hospital, Pilsen, Czech Republic. dostalj@fnplzen.cz. Hauptthemen laut MEDLINE: Trigeminal Neuralgia, Rhizotomy, Tomography, X-Ray Computed, Radiation Exposure. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministerstvo Zdravotnictví Ceské Republiky, Charles University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Percutaneous rhizotomy of the Gasserian ganglion is a well-established intervention for patients suffering from refractory trigeminal pain, not amenable to pharmacological management or microvascular decompression. Traditionally conducted under fluoroscopic guidance using Hartel’s technique, this study investigates a modified approach employing low-dose CT guidance to achieve maximal procedural precision and safety with the emphasis on minimizing radiation exposure.

Methods

A retrospective analysis of patients undergoing percutaneous rhizotomy of the Gasserian ganglion at our institution was undertaken. Procedures were divided into fluoroscopy and CT-guided foramen ovale (FO) cannulation cohorts. Radiation doses were assessed, excluding cases with incomplete data. The study included 32 procedures in the fluoroscopy group and 30 in the CT group.

Results

In the CT-guided group, the median effective dose was 0.21 mSv. The median number of CT scans per procedure was 4.5, and the median procedure time was 15 min. Successful FO cannulation was achieved in all 30 procedures (100%). In the fluoroscopy group, the median effective dose was 0.022 mSv, and the median procedure time was 15 min. Cannulation of FO was successful in 31 of 32 procedures (96.9%). The only complications in the CT-guided group were three minor cheek hematomas. Immediate pain relief in the CT-guided group was reported in 25 of 30 procedures (83.3%), 22 of 30 (73.3%) provided relief at one month, and 10 of 18 (55.6%) procedures resulting in pain relief at one month continued to provide relief after two years.

Conclusion

Low-dose CT-guided percutaneous rhizotomy conducted in the radiology suite carries negligible radiation exposure for patients and eliminates it for personnel. This method is fast, simple, precise, and carries a very low risk of complications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Trigeminal NeuralgiaRhizotomyTomography, X-Ray ComputedRadiation ExposureHumansFemaleMaleRetrospective StudiesMiddle AgedAgedFluoroscopyAdultTrigeminal GanglionRadiation DosageTreatment Outcome

Autor:innen und Institutionen

  • Department of Neurosurgery, Faculty of Medicine in Pilsen, Charles University, University Hospital, Pilsen, Czech Republic. dostalj@fnplzen.cz.
  • Department of Imaging Methods, Faculty of Medicine in Pilsen, Charles University, University Hospital, Pilsen, Czech Republic.
  • Department of Radiological Physics, Faculty of Medicine in Pilsen, Charles University, University Hospital, Pilsen, Czech Republic.
  • Department of Neurosurgery, Faculty of Medicine, University of Ostrava, University Hospital, Ostrava, Czech Republic.
  • Department of Neurosurgery, Faculty of Medicine in Pilsen, Charles University, University Hospital, Pilsen, Czech Republic.

ORCID-Profile: Jiri Dostal, Jan Baxa, Jana Stepankova, Miroslav Seidl, Jan Mracek, Pavel Lavicka, Tomas Malkus, Vladimir Priban

Förderung

  • Ministerstvo Zdravotnictví Ceské Republiky
  • Charles University

Zitieren

APA

Dostal, J., Baxa, J., Stepankova, J., Seidl, M., Mracek, J., Lavicka, P., Malkus, T., & Priban, V. (2024). Radiation exposure and safety in low-dose CT-guided glycerol rhizotomy for trigeminal Neuralgia outside the operating room. Acta Neurochirurgica. https://doi.org/10.1007/s00701-024-06364-9

Vancouver

Dostal J, Baxa J, Stepankova J, Seidl M, Mracek J, Lavicka P, et al. Radiation exposure and safety in low-dose CT-guided glycerol rhizotomy for trigeminal Neuralgia outside the operating room. Acta Neurochirurgica. 2024. doi:10.1007/s00701-024-06364-9

BibTeX
@article{Dostal2024,
  author = {Dostal, Jiri and Baxa, Jan and Stepankova, Jana and Seidl, Miroslav and Mracek, Jan and Lavicka, Pavel and Malkus, Tomas and Priban, Vladimir},
  title = {Radiation exposure and safety in low-dose CT-guided glycerol rhizotomy for trigeminal Neuralgia outside the operating room},
  journal = {Acta Neurochirurgica},
  year = {2024},
  doi = {10.1007/s00701-024-06364-9}
}
Kostenlos starten →