Fachartikel in der Zeitschrift Acta Neurochirurgica, 2024. Verfasst von Lukas Bobinski und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics, Spine Section, University Hospital Umeå, Umeå, Sweden. Lukas.bobinski@umu.se. Hauptthemen laut MEDLINE: Spinal Fusion, Spinal Nerve Roots, Cervical Vertebrae. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Swedish Regional Research Council (FoU Västerbotten), Umea University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Instrumentation of the C1 vertebra requires either mobilization or transection of the C2 nerve root. This study investigates clinical and radiological outcomes and incidences of C2 neuropathic pain after posterior instrumented fusion in the cranio-cervical junction with or without division of the C2 nerve roots.

Methods

This retrospective study compared two cohorts of patients who underwent instrumented fusion in the cranio-cervical junction. Fifty patients (22 males and 28 females) were operated with complete resection of C2 nerve root ganglion (Ex group), and fifty-one patients (30 men, 21 women) with C2 nerve roots preservation (No group).

Results

The incidence of postoperative C2 neuropathy was eight times lower in the Ex group compared to the No group that was statistical significant, p = 0.039. Surgical time was significantly shorter in the No group ( p = 0.001). The fusion rates were very high for both groups, without difference between groups ( p = 1.0). Autografting from the iliac crest ( p = 0.001) as well as postoperative immobilisation with a hard collar ( p < 0.001) were required in fewer patients in the Ex group. Also, patients in the Ex group were mobilised faster after surgery ( p = 0.49). Overall, complication rates were similar between groups, but the Ex group demonstrated fewer major medical complications (16% vs 31%). Male sex and iliac bone harvesting demonstrated significantly higher OR for development of postoperative complications ( p = 0.023 and p = 0.034 respectively) and postoperative mobilization demonstrated significant higher OR for development of postoperative major complications ( p = 0.042).

Conclusions

Resection of the C2 nerve root ganglion during posterior instrumented fusion of the cranio-cervical junction is safe and rarely leads to C2 neuropathy. The technique tends to mitigate the odds of developing postoperative complications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Spinal FusionSpinal Nerve RootsCervical VertebraeHumansMaleFemaleMiddle AgedRetrospective StudiesAgedAdultFluoroscopyTreatment OutcomePostoperative ComplicationsNeuralgiaImaging, Three-Dimensional

Stichwörter der Autor:innen

C2 nerve root ganglionCranio-cervical junctionNeurectomyOccipital neuralgiaRadiculopathy

Autor:innen und Institutionen

  • Department of Orthopedics, Spine Section, University Hospital Umeå, Umeå, Sweden. Lukas.bobinski@umu.se.
  • Department of Diagnostics and Intervention, Orthopedics, Umeå University, Umeå, Sweden. Lukas.bobinski@umu.se.
  • Department of Orthopedics, Spine Section, University Hospital Umeå, Umeå, Sweden.
  • Department of Cardiology, Sunderbyn Hospital, Luleå, Sweden.
  • Epistat AB, Statistical Analysis, Uppsala Science Park, Uppsala, Sweden.
  • I3Spine International, Vaud, Switzerland.

ORCID-Profile: Lukas Bobinski, John M Duff

Förderung

  • Swedish Regional Research Council (FoU Västerbotten)
  • Umea University

Zitieren

APA

Bobinski, L., Sandberg, L., Bylander, F., Hållberg, H., Berglund, A., & Duff, J. M. (2024). Safety and efficacy of the new modified technique for c2 nerve root resection in 3d fluoroscopy navigated instrumentation in the cranio-cervical junction. Acta Neurochirurgica. https://doi.org/10.1007/s00701-024-06265-x

Vancouver

Bobinski L, Sandberg L, Bylander F, Hållberg H, Berglund A, Duff JM. Safety and efficacy of the new modified technique for c2 nerve root resection in 3d fluoroscopy navigated instrumentation in the cranio-cervical junction. Acta Neurochirurgica. 2024. doi:10.1007/s00701-024-06265-x

BibTeX
@article{Bobinski2024,
  author = {Bobinski, Lukas and Sandberg, Linda and Bylander, Frida and Hållberg, Hampus and Berglund, Anders and Duff, John M},
  title = {Safety and efficacy of the new modified technique for c2 nerve root resection in 3d fluoroscopy navigated instrumentation in the cranio-cervical junction},
  journal = {Acta Neurochirurgica},
  year = {2024},
  doi = {10.1007/s00701-024-06265-x}
}
Kostenlos starten →