A colorimetric and ratiometric fluorescence dual-mode biosensor based on manganese-doped carbon dots for the detection of chloramphenicol residues
Microchimica Acta · 2026-12 · 193 (12)
DOI: 10.1007/s00604-026-08524-3 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchimica Acta, online erschienen am 09.11.2026. Verfasst von Tongtong Li und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Food Science and Technology, Bohai University, Jinzhou, Liaoning Province, 121013, China. Hauptthemen laut MEDLINE: Chloramphenicol, Carbon Quantum Dots, Biosensing Techniques, Colorimetry. Die Arbeit nennt 35 Literaturangaben.
Abstract (Originalsprache)
A dual-mode (colorimetric/fluorometric) sensing system for monitoring chloramphenicol (CAP) residues has been developed. The detection system was constructed using Fe₃O₄ nanoparticles (Fe₃O₄ NPs) as magnetic separation carriers and Mn-doped carbon dots (Mn-CDs) as signal probes. Fe₃O₄ NPs were conjugated to the CAP aptamer (Apt) via amide linkages, and Mn-CDs were linked to the complementary DNA strand (cDNA).Subsequently, these two components were assembled through base complementarity. In the presence of CAP, the Mn-CDs-cDNA complex undergoes competitive dissociation due to the stronger specific binding between CAP and the aptamer compared with base pairing. Following magnetic separation, the released Mn-CDs-cDNA complex in the supernatant catalyzes the oxidation of o-phenylenediamine (OPD) to 2,3-diaminophenazine (DAP), generating a colorimetric signal with an absorption peak at 450 nm. Simultaneously, a ratiometric fluorescence signal is achieved through the inner filter effect (IFE). DAP formation enhances fluorescence at 550 nm while quenching the blue emission of Mn-CDs at 455 nm. This dual-mode strategy enables the sensitive detection of CAP via monitoring the absorbance intensity and the fluorescence ratio (F550 nm/F455 nm). Under optimized detection conditions, the linear range for the colorimetric mode was 0.002-2 µmol L-1 with a detection limit of 11.6 nmol L-1; the linear range for the fluorometric mode was 0.005-6 µmol L-1 with a detection limit of 4.02 nmol L-1. This method demonstrates reliable performance for the detection of CAP residues in food samples. The dual-mode sensing strategy offers enhanced sensitivity and provides a promising analytical approach for food safety monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- College of Food Science and Technology, Bohai University, Jinzhou, Liaoning Province, 121013, China.
- National & Local Joint Engineering Research Center of Storage, Processing and Safety Control Technology for Fresh Agricultural and Aquatic Products, Jinzhou, Liaoning, 121013, China.
- Food Safety Key Lab of Liaoning Province, Jinzhou, Liaoning, 121013, China.
- Institute of Ocean Research, Jinzhou, Liaoning, 121013, China.
- The Fresh Food Storage and Processing Technology Research Institute of Liaoning Provincial Universities, Jinzhou, Liaoning, 121013, China.
- College of Food Science and Technology, Bohai University, Jinzhou, Liaoning Province, 121013, China. huaxue_gaoxue@126.com.
Zitieren
APA
Li, T., Chen, L., Sun, J., Li, J., Gao, J., & Gao, X. (2026). A colorimetric and ratiometric fluorescence dual-mode biosensor based on manganese-doped carbon dots for the detection of chloramphenicol residues. Microchimica Acta, 193(12). https://doi.org/10.1007/s00604-026-08524-3
Vancouver
Li T, Chen L, Sun J, Li J, Gao J, Gao X. A colorimetric and ratiometric fluorescence dual-mode biosensor based on manganese-doped carbon dots for the detection of chloramphenicol residues. Microchimica Acta. 2026;193(12). doi:10.1007/s00604-026-08524-3
BibTeX
@article{Li2026,
author = {Li, Tongtong and Chen, Litao and Sun, Jianing and Li, Jinyang and Gao, Jiayan and Gao, Xue},
title = {A colorimetric and ratiometric fluorescence dual-mode biosensor based on manganese-doped carbon dots for the detection of chloramphenicol residues},
journal = {Microchimica Acta},
year = {2026},
volume = {193},
number = {12},
doi = {10.1007/s00604-026-08524-3}
}
EUVIMED