Integration of cefradine-modified dextran-coated magnetite nanoparticles and IgG-modified time-resolved fluorescent microsphere with improved performance for ultrasensitive detection of Staphylococcus aureus in clinical samples
Microchimica Acta · 2026
DOI: 10.1007/s00604-026-08336-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchimica Acta, 2026. Verfasst von Yuan-Yuan Zhang und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Endocrinology, Qilu Hospital of Shandong University, Jinan, 250012, People's Republic of China. Hauptthemen laut MEDLINE: Staphylococcus aureus, Dextrans, Magnetite Nanoparticles, Microspheres. Die Arbeit nennt 39 Literaturangaben. Gefördert von: Science Development Fund of Qilu Hospital of Shandong University Dezhou Hospital.
Abstract (Originalsprache)
An improved strategy based on dual-specificity recognition synergy for ultrasensitive detection of viable Staphylococcus aureus (S. aureus) in clinical samples is proposed. A hydrophilic cefradine-modified dextran-coated magnetic nanoparticle (CDMN) was fabricated as a recognition unit for selective capture of target S. aureus. Meanwhile, a hydrophilic IgG-modified time-resolved fluorescent microsphere (ITFM) was prepared as a labeling unit for specific labeling of target S. aureus by the specific interaction between the Fc region of IgG and protein A on the surface of S. aureus. To prove the practicability, the CDMN-linked ITFM (CDMN-ITFM) strategy was constructed for the determination of S. aureus. In short, CDMN selectively captured S. aureus from complex samples containing numerous interfering molecules, and then ITFM specifically labeled S. aureus captured by CDMN; subsequently, the CDMN-bacteria-ITFM complex was isolated and washed, followed by elution to release ITFM; finally, the fluorescence signal of ITFM in the suspension was quantitatively analyzed. Intriguingly, due to the presence of numerous hydrophilic groups in CDMN and ITFM, non-specific adsorption was effectively limited during the capture and labeling of S. aureus, which further reduced background fluorescence signals and improved sensitivity. Therefore, the limit of detection (LOD) of the improved CDMN-ITFM strategy was 8 CFU mL- 1. The CDMN-ITFM strategy was successfully applied to detect viable S. aureus in spiked wound secretion and urine samples, with recovery between 93.4% and 103.7% and relative standard deviation between 2.2% and 6.3%. The CDMN-ITFM strategy has advantages such as low background fluorescence, high sensitivity, fast analysis speed, strong substrate tolerance, and simple operation. We believe that the CDMN-ITFM strategy has broad prospects in the field of ultrasensitive detection of pathogens in different clinical samples.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Endocrinology, Qilu Hospital of Shandong University, Jinan, 250012, People's Republic of China.
- Department of Endocrinology, Qilu Hospital of Shandong University Dezhou Hospital, Dezhou, 253000, People's Republic of China.
- Tianjin Key Laboratory on Technologies Enabling Development of Clinical Therapeutics and Diagnostics, School of Pharmacy, Tianjin Medical University, Tianjin, 300070, People's Republic of China.
- Department of Endocrinology, Qilu Hospital of Shandong University Dezhou Hospital, Dezhou, 253000, People's Republic of China. shy7534@163.com.
- Tianjin Key Laboratory on Technologies Enabling Development of Clinical Therapeutics and Diagnostics, School of Pharmacy, Tianjin Medical University, Tianjin, 300070, People's Republic of China. xianhua.w@163.com.
- Building B for School of Pharmacy, Tianjin Medical University, 22 Qixiangtai Road, Heping District, Tianjin, 300072, China. xianhua.w@163.com.
Förderung
- Science Development Fund of Qilu Hospital of Shandong University Dezhou Hospital
Zitieren
APA
Zhang, Y. Y., Yang, L. X., Cai, Z. X., Yin, M. Z., Song, L., Li, J. H., Zhang, H., Li, H. Y., Shi, H. Y., & Wang, X. H. (2026). Integration of cefradine-modified dextran-coated magnetite nanoparticles and IgG-modified time-resolved fluorescent microsphere with improved performance for ultrasensitive detection of Staphylococcus aureus in clinical samples. Microchimica Acta. https://doi.org/10.1007/s00604-026-08336-5
Vancouver
Zhang YY, Yang LX, Cai ZX, Yin MZ, Song L, Li JH, et al. Integration of cefradine-modified dextran-coated magnetite nanoparticles and IgG-modified time-resolved fluorescent microsphere with improved performance for ultrasensitive detection of Staphylococcus aureus in clinical samples. Microchimica Acta. 2026. doi:10.1007/s00604-026-08336-5
BibTeX
@article{Zhang2026,
author = {Zhang, Yuan-Yuan and Yang, Long-Xin and Cai, Zheng-Xiao and Yin, Ming-Ze and Song, Li and Li, Jun-Hua and Zhang, Han and Li, Han-Yue and Shi, Hai-Yan and Wang, Xian-Hua},
title = {Integration of cefradine-modified dextran-coated magnetite nanoparticles and IgG-modified time-resolved fluorescent microsphere with improved performance for ultrasensitive detection of Staphylococcus aureus in clinical samples},
journal = {Microchimica Acta},
year = {2026},
doi = {10.1007/s00604-026-08336-5}
}
EUVIMED