EUVIMEDEUVIMED entdecken
Crossref

A dual-mode aptasensor based on UiO-66-NH₂@MOF-919 for subtype-specific detection of carbapenem-resistant Klebsiella pneumoniae

Ruiwen Li, Hao Shen, Dandan Shi, Shaoning Yu, Guoqing Qian

Microchimica Acta · 2026-08 · 193 (8)

DOI: 10.1007/s00604-026-08254-6 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microchimica Acta, online erschienen am 03.07.2026. Verfasst von Ruiwen Li und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Infectious Diseases, The First Affiliated Hospital of Ningbo University, Ningbo, 315211, Zhejiang, China. Hauptthemen laut MEDLINE: Klebsiella pneumoniae, Biosensing Techniques, Aptamers, Nucleotide, Metal-Organic Frameworks. Die Arbeit nennt 47 Literaturangaben. Gefördert von: Ningbo University Biomedical Innovation Institute Project, the Key Project of Zhejiang Provincial Medical and Health Science and Technology Plan, Ningbo Municipal Major Project for Medical and Health High-Level Teams.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rapid and reliable detection of multidrug-resistant bacteria is essential for effective clinical management. In this study, we have developed a dual-mode aptasensing platform based on a core-shell MOF-on-MOF structure (UiO-66-NH₂@MOF-919) for the subtype-specific detection of carbapenem-resistant Klebsiella pneumoniae strains carrying NDM-1 and KPC-2. This bifunctional system integrates the peroxidase-like activity of the MOF-919 shell with the fluorescence quenching capability of the UiO-66-NH₂ core, enabling both colorimetric and fluorometric detection within a single platform. Benefiting from this design, the method achieves sensitive and selective detection over a wide linear range from 10 to 10⁸ CFU mL⁻¹, with low detection limits of 7 CFU mL⁻¹ for NDM-1 KP and 4 CFU mL⁻¹ for KPC-2 KP. The proposed platform exhibits good selectivity against non-target bacteria and strong anti-interference capability. Spiked recovery experiments in human serum, urine, and bronchoalveolar lavage fluid yielded recoveries ranging from 93.0% to 110.0% with RSDs below 5.0%, demonstrating good analytical accuracy and applicability in complex biological samples. Compared to conventional aptasensing systems, this approach enables dual-subtype detection within a single platform, improving analytical efficiency and practicality. This work provides a feasible strategy for MOF-on-MOF-based biosensing systems and shows promising potential for rapid clinical detection of drug-resistant bacteria.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Klebsiella pneumoniaeBiosensing TechniquesAptamers, NucleotideMetal-Organic FrameworksHumansCarbapenemsbeta-LactamasesLimit of DetectionColorimetrySpectrometry, FluorescenceAnti-Bacterial AgentsPhthalic Acids

Stichwörter der Autor:innen

Klebsiella pneumoniaeAptasensorCarbapenem resistanceDual-mode detectionFluorescenceMOF-on-MOFMultidrug-resistant bacteriaUV-vis spectrometry

Substanzen

Carbapenemsbeta-LactamasesAptamers, NucleotideUiO-66Metal-Organic Frameworksbeta-lactamase NDM-1Anti-Bacterial AgentsPhthalic Acids

Autor:innen und Institutionen

  • Department of Infectious Diseases, The First Affiliated Hospital of Ningbo University, Ningbo, 315211, Zhejiang, China.
  • Institute of Mass Spectrometry, School of Material Science and Chemical Engineering, Ningbo University, Ningbo, 315211, Zhejiang, China.
  • Health Science Center, Ningbo University, Ningbo, 315211, Zhejiang, China.
  • Department of Infectious Diseases, The First Affiliated Hospital of Ningbo University, Ningbo, 315211, Zhejiang, China. bill.qian@outlook.com.

Förderung

  • Ningbo University Biomedical Innovation Institute Project
  • the Key Project of Zhejiang Provincial Medical and Health Science and Technology Plan
  • Ningbo Municipal Major Project for Medical and Health High-Level Teams
  • Ningbo Key Discipline of Medical Sciences

Zitieren

APA

Li, R., Shen, H., Shi, D., Yu, S., & Qian, G. (2026). A dual-mode aptasensor based on UiO-66-NH₂@MOF-919 for subtype-specific detection of carbapenem-resistant Klebsiella pneumoniae. Microchimica Acta, 193(8). https://doi.org/10.1007/s00604-026-08254-6

Vancouver

Li R, Shen H, Shi D, Yu S, Qian G. A dual-mode aptasensor based on UiO-66-NH₂@MOF-919 for subtype-specific detection of carbapenem-resistant Klebsiella pneumoniae. Microchimica Acta. 2026;193(8). doi:10.1007/s00604-026-08254-6

BibTeX
@article{Li2026,
  author = {Li, Ruiwen and Shen, Hao and Shi, Dandan and Yu, Shaoning and Qian, Guoqing},
  title = {A dual-mode aptasensor based on UiO-66-NH₂@MOF-919 for subtype-specific detection of carbapenem-resistant Klebsiella pneumoniae},
  journal = {Microchimica Acta},
  year = {2026},
  volume = {193},
  number = {8},
  doi = {10.1007/s00604-026-08254-6}
}
Kostenlos starten →