Single source precursor-enabled NiS nanosheets on flexible carbon cloth for sensitive electrochemical detection of chloramphenicol in food and biological matrix
Microchimica Acta · 2026-08 · 193 (8)
DOI: 10.1007/s00604-026-08251-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchimica Acta, online erschienen am 13.07.2026. Verfasst von Prajakta N Gaikwad und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Ecole Centrale School of Engineering, Mahindra University, Hyderabad, 500043, India. Hauptthemen laut MEDLINE: Chloramphenicol, Electrochemical Techniques, Carbon, Nanostructures. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 88 Literaturangaben. Gefördert von: IIIT-iHub funding, DST-Anusandhan National Research Foundation (ANRF)-advanced research grant (ARG).
Abstract (Originalsprache)
The successful low-temperature, in-situ solvothermal strategy for the direct growth of nickel sulfide (NiS) nanostructures on flexible, conductive carbon cloth (CC) using a single-source precursor, Ni[S₂P(OC₃H₇)₂] is reported. This solution-processed approach enables the formation of highly-quality, crystalline and stoichiometric NiS films with a distinctive fern-like, porous nanosheet morphology, providing abundant electroactive sites and facilitating rapid electron transfer. The as-fabricated NiS/CC electrode exhibits excellent electrochemical sensing performance toward CAP, with a wide linear detection range (0.001-300 µM), an ultra-low detection limit (0.0012 µM), and high sensitivity (0.23 mA µM⁻¹ cm⁻²). Additionally, the sensor demonstrates excellent reproducibility, long-term stability, and strong selectivity against potential interfering species. Furthermore, the real-sample analysis with the proposed sensor demonstrates accurate determination of CAP in milk, honey, eye drops, and fetal bovine serum (FBS), with desirable recovery. Collectively, these findings establish SSP derived nanostructured NiS films as a promising material platform for next-generation flexible electrochemical sensors for antibiotic detection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, Ecole Centrale School of Engineering, Mahindra University, Hyderabad, 500043, India.
- School of Nanoscience and Biotechnology, Shivaji University, Kolhapur, 416004, India.
- Centre for Life Sciences, Mahindra University, Hyderabad, 500043, India.
- Interdisciplinary Center for Nanosensors and Nanomedicines, Mahindra University, Hyderabad, 500043, India.
- Department of Chemistry, Ecole Centrale School of Engineering, Mahindra University, Hyderabad, 500043, India. chitra.gurnani@mahindrauniversity.edu.in.
- Interdisciplinary Center for Nanosensors and Nanomedicines, Mahindra University, Hyderabad, 500043, India. chitra.gurnani@mahindrauniversity.edu.in.
ORCID-Profile: Chitra Gurnani
Förderung
- IIIT-iHub funding
- DST-Anusandhan National Research Foundation (ANRF)-advanced research grant (ARG)
Zitieren
APA
Gaikwad, P. N., Lingras, P., Tatipaka, A., Kumar, S., Ghosh, S., & Gurnani, C. (2026). Single source precursor-enabled NiS nanosheets on flexible carbon cloth for sensitive electrochemical detection of chloramphenicol in food and biological matrix. Microchimica Acta, 193(8). https://doi.org/10.1007/s00604-026-08251-9
Vancouver
Gaikwad PN, Lingras P, Tatipaka A, Kumar S, Ghosh S, Gurnani C. Single source precursor-enabled NiS nanosheets on flexible carbon cloth for sensitive electrochemical detection of chloramphenicol in food and biological matrix. Microchimica Acta. 2026;193(8). doi:10.1007/s00604-026-08251-9
BibTeX
@article{Gaikwad2026,
author = {Gaikwad, Prajakta N and Lingras, Payal and Tatipaka, Abhijay and Kumar, Shrawan and Ghosh, Souradyuti and Gurnani, Chitra},
title = {Single source precursor-enabled NiS nanosheets on flexible carbon cloth for sensitive electrochemical detection of chloramphenicol in food and biological matrix},
journal = {Microchimica Acta},
year = {2026},
volume = {193},
number = {8},
doi = {10.1007/s00604-026-08251-9}
}
EUVIMED