A surface-enhanced Raman scattering sensor based on tetrahedral DNA-Ag@4-ATP nanostructures for ultrasensitive detection of ochratoxin A
Microchimica Acta · 2026
DOI: 10.1007/s00604-026-07909-8 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchimica Acta, 2026. Verfasst von Liming Guo und 8 weiteren Autor:innen. Beteiligte Einrichtung: National & Local Joint Engineering Research Center for Deep Utilization Technology of Mineral Salt Resource, and Key Laboratory for Palygorskite Scie…. Hauptthemen laut MEDLINE: Ochratoxins, Spectrum Analysis, Raman, Biosensing Techniques. Die Arbeit nennt 43 Literaturangaben. Gefördert von: Jiangsu Education Department, Open Fund Program of National & Local Joint Engineering Research Center for Mineral Salt Deep Utilization, the National Natural Science Foundations of China.
Abstract (Originalsprache)
An innovative "turn-on" surface-enhanced Raman scattering (SERS) biosensor for ultrasensitive ochratoxin A (OTA) monitoring by a tetrahedral DNA nanostructure (TDN) is introduced, which provides high mechanical strength and stability. The TDN framework was engineered with an OTA-specific aptamer conjugated at one edge, while two adjacent vertices were functionalized with Ag@4-aminothiophenol (4-ATP) nanoparticles via thiolated linker strands. Upon target recognition, aptamer-OTA binding triggers a programmable conformational switching of the TDN. This switching spatially regulates the electromagnetic field coupling between adjacent Ag@4-ATP hotspots, thereby amplifying the SERS signal in a target-dependent manner. Compared to conventional SERS platforms, this strategy exhibits higher sensitivity, with a linear response over six orders of magnitude (0.39–10000 pg/mL, R2 = 0.998) and an ultralow limit of detection (LOD) of 0.117 pg/mL. Field validation using spiked peanut and soybean samples showed excellent correlation with high-performance liquid chromatography (HPLC) reference measurements, while reducing the analysis time from > 1 h to < 5 min per sample. By modifying the tetrahedral DNA sequences, this approach holds promise for the detection of multiple mycotoxins in food enhancing food safety and protecting public health.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- National & Local Joint Engineering Research Center for Deep Utilization Technology of Mineral Salt Resource, and Key Laboratory for Palygorskite Science and Applied Technology of Jiangsu Province, Huaiyin Institute of T…
- Key Laboratory of Polymer Ecomaterials, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022, China. bying@ciac.ac.cn.
- Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing, 100190, People's Republic of China.
Förderung
- Jiangsu Education Department
- Open Fund Program of National & Local Joint Engineering Research Center for Mineral Salt Deep Utilization
- the National Natural Science Foundations of China
- the Huaishang Talents Program and the Excellent Doctoral Program for Universities in Huai’an
Zitieren
APA
Guo, L., Wang, B., Zhang, J., Ma, X., Zhu, X., Feng, L., Bao, Y., Zhang, J., & Chen, Y. (2026). A surface-enhanced Raman scattering sensor based on tetrahedral DNA-Ag@4-ATP nanostructures for ultrasensitive detection of ochratoxin A. Microchimica Acta. https://doi.org/10.1007/s00604-026-07909-8
Vancouver
Guo L, Wang B, Zhang J, Ma X, Zhu X, Feng L, et al. A surface-enhanced Raman scattering sensor based on tetrahedral DNA-Ag@4-ATP nanostructures for ultrasensitive detection of ochratoxin A. Microchimica Acta. 2026. doi:10.1007/s00604-026-07909-8
BibTeX
@article{Guo2026,
author = {Guo, Liming and Wang, Bo and Zhang, Jie and Ma, Xiangyu and Zhu, XiuFang and Feng, Liangdong and Bao, Ying and Zhang, Jiadong and Chen, Yi},
title = {A surface-enhanced Raman scattering sensor based on tetrahedral DNA-Ag@4-ATP nanostructures for ultrasensitive detection of ochratoxin A},
journal = {Microchimica Acta},
year = {2026},
doi = {10.1007/s00604-026-07909-8}
}
EUVIMED