Influence of CuO on the performance of conducting polymer matrix for screen-printed humidity sensing applications
Microchimica Acta · 2026-03 · 193 (3)
DOI: 10.1007/s00604-026-07897-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchimica Acta, online erschienen am 17.02.2026. Verfasst von B S Manjunatha und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Manipal Academy of Higher Education, Manipal.
Abstract (Originalsprache)
A flexible polyethylene terephthalate (PET) substrate was employed for the fabrication of a resistive-type humidity sensor using screen-printed polypyrrole (PPy)/CuO nanocomposite conductive inks. A series of conducting polymer-metal oxide composite-based sensors with varying compositions was prepared, and their humidity-sensing performances were systematically evaluated. The structural and morphological features of the composites were characterized using scanning electron microscopy (SEM), Fourier-transform infrared spectroscopy (FTIR), and X-ray diffraction (XRD). The sensing behaviour of the printed devices was investigated over a relative humidity (RH) range 22–97% at room temperature, focusing on parameters such as relative resistance, sensitivity, dynamic response, and hysteresis. Enhanced sensitivity was achieved with the incorporation of CuO into PPy. The superior sensing performance is attributed to the combined structural characteristics and hydrophilic nature of CuO. The PPy/CuO nanocomposite with a 1:1 weight ratio, prepared via mechanical mixing and screen printing, exhibited the highest sensitivity over a broad humidity range (22–97% RH), along with fast response/recovery times (~ 50/60 s) and negligible hysteresis.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Chemistry, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India.
- Department of Humanities and Management, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India.
- Department of Chemistry, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India. selva.kumar@manipal.edu.
Förderung
- Manipal Academy of Higher Education, Manipal
Zitieren
APA
Manjunatha, B. S., Shetty, S., Saquib, M., Rao, S. A., Nayak, R., Kamath, V., & Selvakumar, M. (2026). Influence of CuO on the performance of conducting polymer matrix for screen-printed humidity sensing applications. Microchimica Acta, 193(3). https://doi.org/10.1007/s00604-026-07897-9
Vancouver
Manjunatha BS, Shetty S, Saquib M, Rao SA, Nayak R, Kamath V, et al. Influence of CuO on the performance of conducting polymer matrix for screen-printed humidity sensing applications. Microchimica Acta. 2026;193(3). doi:10.1007/s00604-026-07897-9
BibTeX
@article{Manjunatha2026,
author = {Manjunatha, B S and Shetty, Shilpa and Saquib, Mohammad and Rao, Suma A and Nayak, Ramakrishna and Kamath, Vinod and Selvakumar, M},
title = {Influence of CuO on the performance of conducting polymer matrix for screen-printed humidity sensing applications},
journal = {Microchimica Acta},
year = {2026},
volume = {193},
number = {3},
doi = {10.1007/s00604-026-07897-9}
}
EUVIMED