EUVIMEDEUVIMED entdecken
Crossref

Integrating monolithic sorbent micro-solid-phase extraction with anodized screen-printed graphene electrode for serotonin neurotransmitter detection in the presence of ascorbic acid and uric acid

Jeerakit Thangphatthanarungruang, Wichayaporn Kamsong, Kesara Ar-Sanork, Pattanun Ngaosri, Chanchai Charonpongsuntorn, Papan Thaipisuttikul, Warawut Tiyapongpattana, Patcharin Chaisuwan, Chanpen Karuwan

Microchimica Acta · 2026-02 · 193 (2)

DOI: 10.1007/s00604-026-07837-7 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microchimica Acta, online erschienen am 14.01.2026. Verfasst von Jeerakit Thangphatthanarungruang und 8 weiteren Autor:innen. Beteiligte Einrichtung: National Nanotechnology Center (NANOTEC), National Science and Technology Development Agency (NSTDA), Phahonyothin Road, Khlong Nueng, Khlong Luang, …. Hauptthemen laut MEDLINE: Solid Phase Microextraction, Serotonin, Electrodes, Graphite. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: National Research Council of Thailand (NRCT), National Science and Technology Development Agency (NSTDA) under the NSTDA Postdoctoral Fellowship Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A novel analytical method is proposed that integrates monolithic sorbent micro-solid-phase extraction (µ-SPE) with an anodized screen-printed graphene electrode for the determination of serotonin (SER). Monolithic sorbent µ-SPE offers a straightforward and efficient pretreatment method for removing of interfering substances, thereby enhancing the selectivity of SER analysis before being coupled with an electrochemical sensor. Under optimal conditions, the integration of monolithic sorbent µ-SPE with the electrochemical sensor provided a broad linear range of 50-1500 nM for SER detection, with detection and quantification limits of 4.78 and 15.94 nM, respectively. The developed sensor exhibited excellent reproducibility (RSD < 10%) and good stability over a period of 6 months. Furthermore, the proposed method can detect SER even in the presence of ascorbic acid and uric acid at their normal levels in human biological fluids. This method was successfully applied to determine SER levels in real urine samples with an acceptable recovery range of 93.76%-124.14%. The analytical results derived from the developed methodology are strongly correlated with those obtained using the standard high-performance liquid chromatography method.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Solid Phase MicroextractionSerotoninElectrodesGraphiteHumansNeurotransmitter AgentsAscorbic AcidUric Acid

Stichwörter der Autor:innen

Electrochemical sensorMonolithic sorbentNeurotransmittersScreen-printed electrodeSerotoninSolid-phase extractionSquare wave voltammetry

Substanzen

Neurotransmitter AgentsAscorbic AcidUric AcidSerotoninGraphite

Autor:innen und Institutionen

  • National Nanotechnology Center (NANOTEC), National Science and Technology Development Agency (NSTDA), Phahonyothin Road, Khlong Nueng, Khlong Luang, Pathum Thani, 12120, Thailand.
  • Department of Internal Medicine, Faculty of Medicine, Srinakharinwirot University, Nakhon Nayok, 26120, Thailand.
  • Department of Psychiatry, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, 10400, Thailand.
  • Department of Chemistry, Faculty of Science and Technology, Thammasat University, Khlong Luang, Pathum Thani, 12120, Thailand.
  • School of Chemistry, Institute of Science, Suranaree University of Technology, 111 University Avenue, Muang District, Nakhon Ratchasima, 30000, Thailand.
  • National Nanotechnology Center (NANOTEC), National Science and Technology Development Agency (NSTDA), Phahonyothin Road, Khlong Nueng, Khlong Luang, Pathum Thani, 12120, Thailand. chanpen.kar@nanotec.or.th.

Förderung

  • National Research Council of Thailand (NRCT)
  • National Science and Technology Development Agency (NSTDA) under the NSTDA Postdoctoral Fellowship Program

Zitieren

APA

Thangphatthanarungruang, J., Kamsong, W., Ar-Sanork, K., Ngaosri, P., Charonpongsuntorn, C., Thaipisuttikul, P., Tiyapongpattana, W., Chaisuwan, P., & Karuwan, C. (2026). Integrating monolithic sorbent micro-solid-phase extraction with anodized screen-printed graphene electrode for serotonin neurotransmitter detection in the presence of ascorbic acid and uric acid. Microchimica Acta, 193(2). https://doi.org/10.1007/s00604-026-07837-7

Vancouver

Thangphatthanarungruang J, Kamsong W, Ar-Sanork K, Ngaosri P, Charonpongsuntorn C, Thaipisuttikul P, et al. Integrating monolithic sorbent micro-solid-phase extraction with anodized screen-printed graphene electrode for serotonin neurotransmitter detection in the presence of ascorbic acid and uric acid. Microchimica Acta. 2026;193(2). doi:10.1007/s00604-026-07837-7

BibTeX
@article{Thangphatthanarungruang2026,
  author = {Thangphatthanarungruang, Jeerakit and Kamsong, Wichayaporn and Ar-Sanork, Kesara and Ngaosri, Pattanun and Charonpongsuntorn, Chanchai and Thaipisuttikul, Papan and Tiyapongpattana, Warawut and Chaisuwan, Patcharin and Karuwan, Chanpen},
  title = {Integrating monolithic sorbent micro-solid-phase extraction with anodized screen-printed graphene electrode for serotonin neurotransmitter detection in the presence of ascorbic acid and uric acid},
  journal = {Microchimica Acta},
  year = {2026},
  volume = {193},
  number = {2},
  doi = {10.1007/s00604-026-07837-7}
}
Kostenlos starten →